Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (14)
- Vortrag (10)
- Beitrag zu einem Sammelband (3)
Sprache
- Englisch (27)
Schlagworte
- Quantification (27) (entfernen)
Organisationseinheit der BAM
Eingeladener Vortrag
- nein (10)
The amount of grafted poly(acrylic acid) on poly(methyl methacrylate) micro- and nanoparticles was quantified by conductometry, 13C solid-state NMR, fluorophore labeling, a supramolecular assay based on high-affinity binding of cucurbit[7]uril, and two colorimetric assays based on toluidine blue and nickel complexation by pyrocatechol violet. The methods were thoroughly validated and compared with respect to reproducibility, sensitivity, and ease of use. The results demonstrate that only a small but constant fraction of the surface functional groups is accessible to covalent surface derivatization independently of the total number of surface functional groups, and different contributing factors are discussed that determine the number of probe molecules which can be bound to the polymer surface. The fluorophore labeling approach was modified to exclude artifacts due to fluorescence quenching, but absolute quantum yield measurements still indicate a major uncertainty in routine fluorescence-based surface group quantifications, which is directly relevant for biochemical assays and medical diagnostics. Comparison with results from protein labeling with streptavidin suggests a porous network of poly(acrylic acid) chains on the particle surface, which allows diffusion of small molecules (cutoff between 1.6 and 6.5 nm) into the network.
Risk assessment of nanomaterials requires not only standardized toxicity studies but also validated methods for nanomaterial surface characterization with known uncertainties. In this context, a first bilateral interlaboratory comparison on Surface group quantification of nanomaterials is presented that assesses different reporter-free and labeling methods for the quantification of the total and accessible number of amine functionalities on commercially available silica nanoparticles that are widely used in the life sciences. The overall goal of this comparison is the identification of optimum methods as well as achievable measurement uncertainties and the comparability of the results across laboratories. We also examined the robustness and ease of implementation of the applied analytical methods and discussed method-inherent limitations. In summary, this comparison presents a first step toward the eventually required standardization of methods for surface group quantification.
The surface chemistry / functionalization of nanomaterials and microparticles largely controls the stability of these materials as well as their solubility and subsequent biofunctionalization and their interactions with biological systems. Moreover, in the case of some nanomaterials like semiconductor quantum dots or lanthanide-based upconversion nanocrystals, the ligand shell strongly affects their optical properties, e.g., via passivation of surface states and traps that favor luminescence quenching or the protection of surface atoms from quenching water molecules. This renders analytical methods for the quantification of surface groups like functionalities very important. Targets of broad interest are here amino, carboxyl, alkine and maleimide groups used for common bioconjugation reactions and typical ligands like thiols and polyethylene glycol (PEG) molecules of varying length, used for the tuning of material hydrophilicity and biocompatibility, minimization of unspecific interactions, prevention of biofouling, and enhancement of blood circulation times as well as surface-bound biomolecules like streptavidin or other biomolecules relevant e.g., for diagnostic assays. Here, we focus on simple optical methods relying on standard laboratory instrumentation, validated by method comparison and/or mass balances and present examples for their use for the characterization of different types of nanomaterials and microparticles.
Luminescence-based detection methods, ranging from fluorescence spectroscopy for photophysical and mechanistic studies over sensing applications, chromatographic separation techniques and the microarray technology with fluorescence detection to fluorescence microscopy, flow cytometry, single molecule spectroscopy, and molecular imaging to integrating sphere spectroscopy, are among the most widely used methods in the life and material sciences. This is due to e.g., their unique sensitivity enabling the detection of single molecules, potential for multiplexing, ease of combination with spatial resolution, and suitability for remote sensing. Many of these advantages are closely linked to the choice of suitable molecular and nanoscale fluorescent reporters, typically required for signal generation. This includes organic dyes without and with sensor function, fluorophore-encoded polymeric and silica nanoparticles as well as nanocrystalline systems like semiconductor quantum dots and upconversion phosphors, emitting in the visible (vis), near-infrared (NIR), and IR (infrared). Current challenges present the environment sensitivity of most fluorophores, rendering fluorescence spectra, measured intensities/fluorescence quantum yields, and fluorescence decay kinetics matrix-dependent, and instrument-specific distortions of measured fluorescence signals that need to be considered for quantification and comparability of data, particularly fluorescence spectra.
Here, current applications of luminescence-based methods and different types of reporters will be presented. In this context, suitable spectroscopic tools for the characteri-zation of the optical properties of fluorescent reporters and fluorophore-encoded microparticles, analytical tools for the determination of the surface chemistry of different types of particles, and different multiplexing strategies will be discussed.
The aim of this article is to illustrate the need for an improved quality assurance in fluorescence microscopy. From the instrument-side, this can be achieved by a better understanding, consideration, and regular control of the instrument-specific parameters and quantities affecting measured fluorescence signals. Particularly, the need for requirements on physical- and chemical-type instrument standards for the characterization and performance validation of spectral fluorescence microscopes (SFMs) is discussed and suitable systems are presented. Special emphasis is given to spectral fluorescence standards and to day-to-day intensity standards for SFMs. Fluorescence standards and well-characterized fluorescence microscopes are the first and essential steps towards the comparability and the understanding of the variability in fluorescence microscopy data in medical and life sciences. In addition, standards enable the distinction between instrument-specific variations and fluorescent label- or probe-related uncertainties as well as generally sample-related effects.
We present a novel, simple, and fast colorimetric method to quantify the total number of carboxy groups on polymer microparticle and nanoparticle surfaces. This method exploits that small divalent transition metal cations (M2+ = Ni2+, Co2+, Cd2+) are efficiently bound to these surface functional groups, which allows their extraction by a single centrifugation step. Remaining M2+ in the supernatant is subsequently quantified spectrophotometrically after addition of the metal ion indicator pyrocatechol violet, for which Ni2+ was identified to be the most suitable transition metal cation. We demonstrate that the difference between added and detected M2+ is nicely correlated to the number of surface carboxy groups as determined by conductometry, thereby affording a validated measure for the trueness of this procedure. The variation coefficient of ~5% found in reproducibility studies underlines the potential of this novel method that can find conceivable applications for the characterization of different types of poly(carboxylic acid)-functionalized materials, e.g., for quality control by manufacturers of such materials.
We introduce a method to determine the number of accessible functional groups on a polymer microsphere surface based on the interaction between the macrocyclic host cucurbit[7]uril (CB7) and a guest reacted to the microsphere surface. After centrifugation, CB7 in the supernatant is quantified by addition of a fluorescent dye. The difference between added and detected CB7 affords the number of accessible surface functional groups.
Simple, fast, and versatile methods for the quantification of thiol groups are of considerable interest not only for protein analysis but also for the characterization of the surface chemistry of nanomaterials stabilized with thiol ligands or bearing thiol groups for the subsequent (bio-) functionalization via maleimide−thiol chemistry. Here, we compare two simple colorimetric assays, the widely used Ellman’s assay performed at alkaline pH and the aldrithiol assay executed at acidic and neutral pH, with respect to their potential for the quantification of thiol groups and thiol ligands on different types of nanoparticles like polystyrene nanoparticles, semiconductor nanocrystals (SC NC), and noble metal particles, and we derive criteria for their use. In order to assess the underlying reaction mechanisms and to obtain stoichiometry factors mandatory for reliable thiol quantification, both methods were studied photometrically and with electrospray ionization time-of-flight mass spectrometry (ESI-TOF-MS), thereby demonstrating the influence of different thiols on the reaction mechanism. Our results underline the suitability of both methods for the quantification of directly accessible thiol groups or ligands on the surface of 2D- and 3D-supports, here exemplarily polystyrene nanoparticles. Moreover, we could derive strategies for the use of these simple assays for the determination of masked (i.e., not directly accessible) thiol groups like disulfides such as lipoic acid and thiol stabilizing ligands coordinatively bound to Cd and/or Hg surface atoms of II/VI and ternary SC NC and to gold and silver nanoparticles.
Lanthanide-doped upconversion nanoparticles (UCNPs) are of great interest for biomedical applications. Currently, the applicability of UCNP bionanotechnology is hampered by the generally low luminescence intensity of UCNPs and inefficient energy Transfer from UCNPs to surface-bound chromophores used e.g. for photodynamic therapy or analyte sensing. In this work, we address the low-Efficiency issue by developing versatile core-Shell nanostructures, where high-concentration sensitizers and activators are confined in the core and Shell Region of representative hexagonal NaYF2:Yb,Er UCNPs. After Doping concentration optimization, the sensitizer-rich core is able to harvest/accumulate more excitation energy and generate almost one order of Magnitude higher luminescence intesity than conventional homogeneously doped nanostructures. At the same time, the activator Ions located in the Shell enable a ~6 times more efficient resonant energy Transfer from UCNPs to surface-bound acceptor dye molecules due to the short distance between donor-acceptor pairs. Our work provides new insights into the rational design of UCNPs and will greatly encrease the General applicability of upconversion nanotechnologies.