Filtern
Dokumenttyp
- Vortrag (27)
- Zeitschriftenartikel (17)
- Beitrag zu einem Tagungsband (1)
- Sonstiges (1)
- Posterpräsentation (1)
Schlagworte
- Mikroplastik (18)
- Microplastics (12)
- TED-GC-MS (12)
- Analytik (9)
- Microplastic (9)
- TED-GC/MS (7)
- Analysis (6)
- Standardisation (4)
- Aktivkohle (3)
- Harmonisation (3)
Organisationseinheit der BAM
- 6 Materialchemie (47) (entfernen)
Paper des Monats
- ja (1)
Eingeladener Vortrag
- nein (27)
Inputs of plastic impurities into the environment via the application of fertilizers are regulated in Germany and the EU by means of ordinances. Robust and fast analytical methods are the basis of legal regulations. Currently, only macro- and large microplastic contents (>1 mm) are measured. Microplastics (1–1,000 µm), are not yet monitored. Thermal analytical methods are suitable for this purpose, which can determine the mass content and can also be operated fully automatically in routine mode. Thermal extraction desorption-gas chromatography/mass spectrometry (TED-GC/MS) allows the identification of polymers and the determination of mass contents in solid samples from natural environments. In accordance with the German or European Commission (EC) Fertiliser Ordinance, composting plants should be monitored for microplastic particles with this method in the future. In this context a compost plant was sampled. At the end of the rotting process, the compost was sieved and separated in a coarse (>1 mm) and a fine fraction (<1 mm). The fine fraction was processed using density separation comparing NaCl and NaI as possible salt alternative and screened for microplastic masses by TED-GC/MS with additional validation and quality assurance experiments. With TED-GC/MS total microplastics mass contents of 1.1–3.0 μg/mg in finished compost could be detected with polyethylene mainly. What differs much to the total mass of plastics in the coarse fraction with up to 60 μg/mg, which were visually searched, identified via ATR-FTIR and gravimetrically weighted.
There is growing interest in quantifying microplastics in environmental samples. This application note presents a thermal extraction desorption-gas chromatography/mass spectrometry (TED-GC/MS) method that is well suited to automation and increased sample throughput. The method is also able to detect all particle sizes in the sample as long as the limit of detection (LOD) is reached and allows analysis of larger samples of 15 to 25 mg or more. Samples were decomposed by thermogravimetric analysis (TGA), and the gaseous decomposition products were trapped on a solid-phase sorbent, followed by thermal desorption‑gas chromatography/mass spectrometry (TD-GC/MS) using an Agilent 5977B GC/MSD coupled to an Agilent 7890B GC. Target microplastic particle (MP) polymers were identified in environmental samples including surface water, finished compost, house dust, and drinking water. Quantification of MP polymers in environmental samples provided LODs of 0.06 to 2.2 μg, allowing the detection of MPs in trace amounts with sample weights of up to 1 g. Method repeatability was adequate for reliable quantification with RSDs of approximately 6 to 12%.
Die zunehmenden Nachweise von Kunststoffen in verschiedenen Umweltmedien erfahren in den letzten Jahren weltweit ein zunehmendes wissenschaftliches, gesellschaftliches und politisches Interesse. Besondere Aufmerksamkeit erfahren Kunststoffpartikel von 1-1.000 µm, sogenanntes Mikroplastik. Es wurde mittlerweile in Wasser, Böden, Luft und Biota nachgewiesen. Obwohl die Wirkungen auf die natürlichen Umweltfunktionen noch unklar sind und kontrovers diskutiert werden, ist allein durch die ubiquitäre Präsenz eine systematische Erfassung von Eintragsquellen und Verbleib der Partikel über alle Umweltmedien notwendig, um Maßnahmen zur Reduktion der Einträge zu veranlassen.
Für eine zuverlässige Erfassung sind medienübergreifende Verfahren zu entwickeln, welche die drei analytischen Schritte, Probennahme, Probenaufbereitung und Detektion beinhalten. Die Verfahren adressieren unterschiedliche Zielgruppen, welche verschiedene analytische Informationen fordern. Für die akademische Bewertung werden Verfahren mit hohem analytischen Aufwand favorisiert, welche möglichst detaillierte Information über Partikelsorte, -größe, -zahl und -oberflächenbeschaffenheit geben. Im Gegensatz dazu, fordern Anwender aus der Praxis schnelle und einfache Monitoring Verfahren, welche die Bestimmung eines Massengehaltes, bzw. eines Grenzwertes zulassen. Allen ist gemeinsam, dass ein hoher interdisziplinärer Anspruch besteht, der sowohl technische Voraussetzungen zur repräsentativen Probennahme und die Limitationen von Detektionsverfahren berücksichtigt, als auch die Fachkompetenz von Biologen, Umweltwissenschaften, Analytiker und Polymerwissenschaftler einschließt.
Verfahren zum Mikroplastiknachweis müssen auch verschieden Proben mit sehr unterschiedlichen Gehalten an natürlicher Matrix gerecht werden. So müssen allein für Wasser Verfahren entwickelt werden, die Mikroplastik verschiedener Form (sphärische Partikel, komplexe Bruchstücke, Fasern) aus Medien mit sehr variablen Partikelanteil (u.a. Trinkwasser, Oberflächenwasser, Abwasser) repräsentativ erfassen, sowie schnell und kostengünstig sind – einschließlich der notwendigen Probenaufbereitung. Die jeweiligen Detektionsverfahren müssen z.B. einzelne Partikel oder integrale Gehalte über drei Dekadenklassen für thermoplastische und insbesondere auch elastomere Partikelsorten erfassen können.
Die zunehmenden Nachweise von Kunststoffen in verschiedenen Umweltmedien erfahren in den letzten Jahren weltweit ein zunehmendes wissenschaftliches, gesellschaftliches und politisches Interesse. Besondere Aufmerksamkeit erfahren Kunststoffpartikel von 1-1.000 µm sogenanntes Mikroplastik. Es wurde mittlerweile in Wasser, Böden, Luft und Biota nachgewiesen. Obwohl die Wirkungen auf die natürlichen Umweltfunktionen noch unklar sind und kontrovers diskutiert werden, ist allein durch die ubiquitäre Präsenz eine systematische Erfassung von Eintragsquellen und Verbleib der Partikel über alle Umweltmedien notwendig, um Maßnahmen zur Reduktion der Einträge zu veranlassen.
Für eine zuverlässige Erfassung sind medienübergreifende Verfahren zu entwickeln, welche die drei analytischen Schritte, Probennahme, Probenaufbereitung und Detektion beinhalten. Die Verfahren adressieren unterschiedliche Zielgruppen, welche verschiedene analytische Informationen fordern. Für die akademische Bewertung werden Verfahren mit hohem analytischen Aufwand favorisiert, welche möglichst detaillierte Information über Partikelsorte, -größe, -zahl und -oberflächenbeschaffenheit geben. Im Gegensatz dazu, fordern Anwender aus der Praxis schnelle und einfache Monitoring Verfahren, welche die Bestimmung eines Massengehaltes, bzw. eines Grenzwertes zulassen. Allen ist gemeinsam, dass ein hoher interdisziplinärer Anspruch besteht, der sowohl technische Voraussetzungen zur repräsentativen Probennahme und die Limitationen von Detektionsverfahren berücksichtigt, als auch die Fachkompetenz von Biologen, Umweltwissenschaften, Analytiker und Polymerwissenschaftler einschließt.
Verfahren zum Mikroplastiknachweis müssen auch verschieden Proben mit sehr unterschiedlichen Gehalten an natürlicher Matrix gerecht werden. So müssen allein für Wasser Verfahren entwickelt werden, die Mikroplastik verschiedener Form (sphärische Partikel, komplexe Bruchstücke, Fasern) aus Medien mit sehr variablen Partikelanteil (u.a. Trinkwasser, Oberflächenwasser, Abwasser) repräsentativ erfassen sowie schnell und kostengünstig sind – einschließlich der notwendigen Probenaufbereitung. Die jeweiligen Detektionsverfahren müssen z.B. einzelne Partikel oder integrale Gehalte über drei Dekadenklassen für thermoplastische und insbesondere auch elastomere Partikelsorten erfassen können.
The TED-GC-MS analysis is a two-step method. A sample is first decomposed in a thermogravimetric analyzer (TGA) and the gaseous decomposition products are then trapped on a solid-phase adsorber. Subsequently, the solid-phase adsorber is analyzed with thermal desorption gas chromatography mass spectrometry (TDU-GC-MS). This method is ideally suited for the analysis of polymers and their degradation processes. Here, a new entirely automated System is introduced which enables high sample throughput and reproducible automated fractioned collection of decomposition products. Strengths and limitations of the system configuration are elaborated via three examples focused on practical challenges in materials analysis and identification: i) separate analysis of the components of a wood-plastic-composite material, ii) quantitative determination of weight concentration of the constituents of a polymer blend and iii) quantitative analysis of model samples of microplastics in suspended particulate matter.
In this work, a novel boehmite (BA)-embedded organic/inorganic nanocomposite coating based on cycloaliphatic epoxy oligosiloxane (CEOS) resin was fabricated applying UV-induced cationic polymerization. The main changes of the material behavior caused by the nanofiller were investigated with regard to its photocuring kinetics, thermal stability, and glass transition. The role of the particle surface was of particular interest, thus, unmodified nanoparticles (HP14) and particles modified with p-toluenesulfonic acid (OS1) were incorporated into a CEOS matrix in the concentration range of 1–10 wt.%. Resulting nanocomposites exhibited improved thermal properties, with the glass transition temperature (Tg) being shifted from 30 °C for unfilled CEOS to 54 °C (2 wt.% HP14) and 73 °C (2 wt.% OS1) for filled CEOS. Additionally, TGA analysis showed increased thermal stability of samples filled with nanoparticles. An attractive interaction between boehmite and CEOS matrix influenced the curing. Real-time infrared spectroscopy (RT-IR) experiments demonstrated that the epoxide conversion rate of nanocomposites was slightly increased compared to neat resin. The beneficial role of the BA can be explained by the participation of hydroxyl groups at the particle surface in photopolymerization processes and by the complementary contribution of p-toluenesulfonic acid surface modifier and water molecules introduced into the system with nanoparticles.
Tire and road wear particles (TRWPs) are heteroagglomerates of tire rubber and other particles deposited on the road surface and one of the main contributors to non-exhaust emissions of automobile traffic. In this study, samples from road environments were analyzed for their TRWP contents and concentra- tions of eight organic tire constituents. TRWP concentrations were determined by quantifying Zn in the density fraction < 1.9 g/cm ³and by thermal extraction desorption-gas chromatography-mass spectrometry (TED-GC/MS) and the concentrations ranged from 3.7 to 480 mg TRWP/g. Strong and statistically signif- icant correlations with TRWPs were found for 2-hydroxybenzothiazole and 2-aminobenzothiazole, indi- cating that these substances may be suitable markers of TRWPs. The mass distribution of TRWPs in road dust suggests that the main mass fraction formed on roads consists of coarse particles ( > 100 μm). Data for a sedimentation basin indicate that the fine fraction ( < 50 μm) is preferentially transported by road runoffinto receiving waters. The size distribution and density data of TRWP gathered by three different quantitation approaches also suggest that aging of TRWPs leads to changes in their particle density. An improved understanding of the dynamics of TRWP properties is essential to assess the distribution and dissipation of this contaminant of emerging concern in the environment.
A fast method for microplastic detection is thermal extraction desorption‐gas chromatography/mass spectrometry (TED‐GC/MS), which uses polymer‐specific thermal decomposition products as marker compounds to determine polymer mass contents in environmental samples. So far, matrix impacts of different environmental matrices on TED‐GC/MS performance had not yet been assessed systematically. Therefore, three solid freshwater matrices representing different aquatic bodies with varying organic matter contents were spiked with a total of eight polymers. Additionally, for the first time, the two biodegradable polymers polybutylene adipate terephthalate (PBAT) and polylactide (PLA) were analysed using TED‐GC/MS. The methodological focus of this work was on detectability, quality of signal formation as well as realisation of quantification procedures and determination of the limit of detection (LOD) values. Overall, TED‐GC/MS allowed the unambiguous detection of the environmentally most relevant polymers analysed, even at low mass contents: 0.02 wt% for polystyrene (PS), 0.04 wt% for the tyre component styrene butadiene rubber (SBR) and 0.2 wt% for polypropylene (PP), polyethylene (PE) and PBAT. Further, all obtained LOD values were increased in all matrices compared to the neat polymer without matrix. The LOD of the standard polymers were increased similarly (PS: 0.21–0.34 μg, SBR: 0.27–0.38 μg, PP: 0.32–0.36 μg, PMMA: 0.64–1.30 μg, PET: 0.90–1.37 μg, PE: 3.80–6.99 μg) and their decompositions by radical scission processes were not significantly influenced by the matrices. In contrast, matrixspecific LOD increases of both biodegradable polymers PBAT (LOD: 1.41–7.18 μg) and PLA (0.84–20.46 μg) were observed, probably due to their hetero‐functional character and interactions with the matrices. In conclusion, the TED‐GC/MS performance is not solely determined by the type of the polymers but also by the composition of the matrix.
Im Vortrag wird ein Messfiltertiegel als Zusatztool für die TED-GC/MS vorgestellt, welcher für die Probenaufbereitung von kleinen Partikelfrachten oder kleinen Partikelgrößen genutzt werden kann. Er ist Filtereinheit und Messtiegel in einem, wodurch Verluste bei der Überführung der Probe in das Messgefäß sowie Kontaminationen vermindert werden. Das beispiel ist hier die Filtration von Flaschenwasser mit anschließender Detektion mit der TED-GC/MS.
A harmonization of sampling, sample preparation and detection is pivotal in order to obtain comparable data on microplastics (MP) in the environment. This paper develops and proposes a suitable sampling concept for waterbodies that considers different plastic specific properties and influencing factors in the environment.
Both artificial water including defined MP fractions and the discharge of a wastewater treatment plant were used to verify the derived sampling procedure, sample preparation and the subsequent analysis of MP using thermal extraction-desorption gas chromatography - mass spectrometry (TED-GC-MS).
A major finding of this paper is that an application of various particle size classes greatly improves the practical handling of the sampling equipment. Size classes also enable the TED-GC-MS to provide any data on the MP size distribution, a substantial sampling property affecting both the necessary sampling volume and the optimal sampling depth.
In the artificial water with defined MP fractions, the recovery rates ranged from 80 to 110%, depending on the different MP types and MP size classes. In the treated wastewater, we found both Polyethylene and polystyrene in different size classes and quantities.
Microplastic particles are currently detected in almost all environmental compartments. The results of detection vary widely, as a multitude of very different methods are used with very different requirements for analytical validity.
In this work four thermoanalytical methods are compared and their advantages and limitations are discussed. One of them is thermal extraction-desorption gas chromatography mass spectrometry (TED-GC/MS), an analysis method for microplastic detection that has become established in recent years. In addition, thermogravimetric analysis coupled with Fourier-transform infrared spectroscopy (TGA-FTIR) and mass spectrometry (TGA-MS) were applied, two methods that are less common in this field but are still used in other research areas. Finally, microscale combustion calorimeter (MCC) was applied, a method not yet used for microplastic detection.
The presented results are taken from a recently published interlaboratory comparison test by Becker et al. (2020). Here a reference material consisting of suspended matter and specified added polymer masses was examined, and only the results of the recoveries were presented. In the present paper, however, the results for the individual polymers are discussed in detail and individual perspectives for all instruments are shown.
It was found that TED-GC/MS is the most suitable method for samples with unknown matrix and unknown, variable kinds and contents of microplastic. TGA-FTIR is a robust method for samples with known matrix and with defined kinds of microplastic. TGA-MS may offer a solution for the detection of PVC particles in the future. MCC can be used as a very fast and simple screening method for the identification of a potential microplastic load of standard polymers in unknown samples.