Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (179)
- Vortrag (46)
- Beitrag zu einem Tagungsband (10)
- Beitrag zu einem Sammelband (3)
- Sonstiges (1)
- Posterpräsentation (1)
Schlagworte
- LIBS (13)
- ICP-MS (12)
- ELISA (8)
- LC-MS/MS (8)
- Laser ablation (8)
- Acoustic levitation (7)
- Speciation (7)
- Traceability (6)
- Calibration (5)
- Characterization (5)
Organisationseinheit der BAM
- 1 Analytische Chemie; Referenzmaterialien (32)
- P Präsident (28)
- P.0 Präsident und andere (28)
- 1.1 Anorganische Spurenanalytik (15)
- 6 Materialchemie (12)
- 6.3 Strukturanalytik (8)
- 1.6 Anorganische Referenzmaterialien (6)
- 1.7 Organische Spuren- und Lebensmittelanalytik (6)
- 1.8 Umweltanalytik (5)
- 6.1 Oberflächen- und Dünnschichtanalyse (5)
Eingeladener Vortrag
- nein (46)
The stable carbon and nitrogen isotopic composition of urine and milk samples from cattle under different feeding regimes were analysed over a period of six months. The isotope ratios were measured with isotope ratio mass spectrometry (IRMS). The δ13C values of milk and urine were dependent on different feeding regimes based on C3 or C4 plants. The δ13C values are more negative under grass feeding than under maize feeding. The δ13C values of milk are more negative compared to urine and independent of the feeding regime. Under grass feeding the analysed milk and urine samples are enriched in 13C relative to the feed, whereas under maize feeding the 13C/12C ratio of urine is in the same range and milk is depleted in 13C relative to the diet. The difference between the 15N/14N ratios for the two feeding regimes is less pronounced than the 13C/12C ratios. The δ15N values in urine require more time to reach the new equilibrium, whereas the milk samples show no significant differences between the two feeding regimes.
For the investigation of small sample volumes, the use of an acoustic levitator was tested as a `sample holder' for hovering droplets in a synchrotron beam. It might be advantageous to use levitated droplets instead of samples confined in solid holders, especially for the study of crystallization processes where the influence of containing walls has to be minimized. In a first experiment, the crystallization of sodium chloride in a small droplet of aqueous solution has been followed with a time resolution of 30 s. The collected diffraction peaks are compared with data in the ICSD database.
RATIONALE
A fast and reliable online identification of pollen is not yet available. The identification of pollen is based mainly on the evaluation of morphological data obtained by microscopic methods.
METHODS
Matrix-assisted laser desorption/ionization mass spectrometry (MALDI-TOF MS) was applied to the analysis of extracts and milled pollen samples. The obtained MALDI data were explored for characteristic peak patterns which could be subjected to a multivariate statistical analysis.
RESULTS
Two sample preparation methods are presented, which require only minimal or no chemical extraction of the pollen. MALDI pollen spectra could be recorded showing various peak patterns. A multivariate statistics approach allowed the classification of pollen into clusters indicating similarities and differences between various species.
CONCLUSIONS
These results demonstrate the potential and the reliability of MALDI-TOF MS for the identification and, in combination with multivariate statistics, also for the classification of pollen.