Filtern
Dokumenttyp
- Zeitschriftenartikel (6)
- Beitrag zu einem Tagungsband (5)
- Vortrag (5)
- Posterpräsentation (4)
- Forschungsbericht (2)
- Beitrag zu einem Sammelband (1)
- Dissertation (1)
Schlagworte
- Analytik (3)
- SIP (3)
- Fire debris (2)
- Holz (2)
- Ignitable liquids (2)
- Rauchgase (2)
- Rauchgastemperaturen (2)
- Raumbrände (2)
- Tomographie (2)
- Wärmefreisetzung (2)
Eingeladener Vortrag
- nein (5)
Complex resistivity (CR) has been used to investigate the properties and the extent of damage in wood and standing trees. Our laboratory experiments have proved that wood´s anisotropy influences its electrical behaviour. It is a well-established fact that wood exhibits the lowest resistivity amplitudes in the axial direction compared to that in tangential and radial directions. It has been shown that anisotropy affects not only the amplitude but also the phase. Phase values are the highest in the axial direction, particularly in the lower frequency range. The changes in resistivity due to fungi-induced damage were investigated in a long-term laboratory test. With progressing damage, both resistivity and phase decrease. The phase also shows sensitivity to the changes in the structure of wood cell. CR Tomography (CRT) has been employed in the field to detect fungi-infected zones in fallen trees. A number of factors such as the type and age of the tree, and the season seem to influence the CRT results. Among those, the effect of seasonal changes has been demonstrated here. Furthermore CRT can be used to characterise fungi-infected zones in the tree.
The chemical analysis of fire debris represents a crucial part in fire investigations to determine the cause of a fire. A headspace solid-phase microextraction (HS-SPME) procedure for the detection of ignitable liquids in fire debris using a fiber coated with a mixture of three different sorbent materials (Divinylbenzene/Carboxen/Polydimethylsiloxane, DVB/CAR/PDMS) is described. Gasoline and diesel fuel were spiked upon a preburnt matrix (wood charcoal), extracted and concentrated with HS-SPME and then analyzed with gas chromatography/mass spectrometry (GC/MS). The experimental conditions—extraction temperature, incubation and exposure time—were optimized. To assess the applicability of the method, fire debris samples were prepared in the smoke density chamber (SDC) and a controlled-atmosphere cone calorimeter. The developed methods were successfully applied to burnt particleboard and carpet samples. The results demonstrate that the procedure that has been developed here is suitable for detecting these ignitable liquids in highly burnt debris.
Dieser Bericht behandelt die Durchführung, Auswertung und Ergebnisse einer Versuchsserie zu Raumbränden. Diese wurde zur Untersuchung von Fragestellungen zum Einfluss von Brandbeschleuniger auf den Brandverlauf sowie zu den Möglichkeiten des Nachweises des Brandbeschleunigers in kriminaltechnischen Ermittlungen durchgeführt.
Die Versuche haben im Rahmen des Forschungsprojekts Brandspurenanalytik der Bundesanstalt für Materialforschung und -prüfung im Jahr 2012 an der Brandprüfstelle Laue der Gesellschaft für Materialforschung und Prüfungsanstalt für das Bauwesen Leipzig mbH stattgefunden. Im Forschungsprojekt wurden verschiedene Materialien und ihr Brandverhalten in Kombination mit flüssigen Brandbeschleunigern in der Rauchdichtekammer (DIN EN ISO 5659-2), dem Cone Calorimeter (ISO 5660-1) und dem Single Burning Item Test (DIN EN 13823) untersucht. Die Untersuchungen hatten zwei Schwerpunkte.
Einerseits wurde im Anschluss an die Versuche der Brandrückstand mit analytischen Methoden mit dem Ziel des Nachweises des Brandbeschleunigers untersucht. Andererseits dienen die gemessenen Größen wie Massenverlustrate, Wärmefreisetzungsrate und Temperaturen innerhalb der Proben als Vergleichsgrößen bei der Validierung numerischer Simulationen und der genutzten Materialmodelle. Ergänzend zu den kleinskaligen
Versuchen wurden die selben Materialien in den in diesem Bericht vorgestellten Raumbränden verwendet, um das Brandverhalten im Originalmaßstab zu untersuchen.
Der gesamte Bericht gliedert sich in drei Teile. Der hier vorliegende Teil 1 thematisiert den Aufbau, die Durchführung und die brandtechnologische Auswertung der Versuche und diskutiert Untersuchungsergebnisse zum Brandverlauf. In Teil 2 werden die analytischen
Methoden zum Nachweis des Brandbeschleunigers in den Brandrückständen vorgestellt und ausgewertet und in Teil 3 werden Empfehlungen zur Probenahme von Proben zum Brandbeschleunigernachweis auf Basis der gewonnen Erkenntnisse im Forschungsprojekt gegeben sowie die Ergebnisse der in diesem Bericht vorgestellten Versuche
vorgestellt.
Die hier beschriebenen Versuche bildeten einen typischen Wohnzimmerbrand ab. In einem Brandraum mit einer Fläche von 20m² wurden verschiedene Einrichtungsgegenstände, wie Sofas, Regale, ein Esstisch, vier Stühle und ein Couchtisch, als Brandlast angeordnet. Insgesamt wurden fünf Versuche bei identischer Brandlast durchgeführt.
Beim ersten Versuch erfolgte die Zündung mit einem Feuerzeug an einem der Sofas.
Bei den vier weiteren Versuchen wurde mit einem Benzin-Diesel-Gemisch als Brandbeschleuniger an jew. unterschiedlichen Positionen im Brandraum gezündet. Während dem Versuch wurden die Temperaturen im Brandraum mit Mantelthermoelementen, Wärmeströme auf Oberflächen mit Plattenthermometern, die Konzentration verschiedener
Gasspezies, der globale Massenverlust, der Fluidmassenstrom durch die Zuluftöffnung und die Wärmefreisetzungsrate gemessen.
Im Anschluss an den Versuch wurden Brandschutt- und Rußwischproben genommen.
Diese wurden mit dem Ziel des Nachweises der verwendeten Brandbeschleuniger analysiert.
Die Zündung mit Brandbeschleuniger führte primär zu einer erhöhten Brandentwicklungsgeschwindigkeit.
Der Flashover trat bei allen Versuchen, die mit Brandbeschleuniger gezündet wurden, wesentlich früher auf, als bei dem ersten Versuch, der mit einem Feuerzeug gezündet wurde. Die erreichten Maximalwerte der brandtechnologischen Kenngrößen, wie beispielsweise die Temperaturen im Brandraum oder die Wärmefreisetzungsrate,
waren jedoch bei allen fünf Versuchen in der gleichen Größenordnung. Die gewonnen Daten zum Brandverlauf können als Vergleichswerte für numerische Simulationen verwendet werden.
Complex Resistivity on Wood
(2009)
SIP - Tomografie an Bäumen
(2009)
Reconstructing the course of a fire and performing chemical analysis of ignitable liquids in fire debris is an important tool to conduct fire investigations in suspected arson cases. Here, a total of five fire tests has been performed to investigate the effect of fire accelerants on the fire development of a room fire and to prove the capability of analytical methods. Different experimental scenarios have been realized (no accelerant, accelerant applied at different positions, and different amounts of fire accelerant). Each test room was equipped with an identical set of living room furnishing. The location and amount of the fire accelerant applied löschen varied in four of five tests. One experiment was carried out without fire accelerant. Fire quantities such as mass loss (of the entire room), gas temperatures (at several locations in the room), and heat release were determined during the experiments, and chemical-analytical studies were carried out. A headspace solid phase micro extraction procedure, using gas chromatography–mass spectrometry, was used to analyze fire debris samples to potentially detect ignitable liquids. Beside the analysis of fire debris samples, swipe soot samples were analyzed and the detectability of the fire accelerant used was demonstrated. Results show that it is possible to provide evidence of ignitable liquids in soot samples collected from walls. This allows an additional sampling strategy at potential crime scenes, besides taking fire debris samples.
The method of low-frequency impedance spectroscopy has been successfully applied in Earth sciences to characterize soils and rocks. The method uses the diagnosing power of complex electrical resistivity in a frequency range between 1 mHz and 1 kHz. In our study, the potential of this method has been explored for the investigation of wood. We observed remarkable differences in the resulting spectra of complex resistivity for different European and Tropical tree species. The data processing of the acquired low-frequency impedance spectra yields integrating parameters. The comparison of the integrating parameters with the mean pore diameter that has been separately determined for the tropical tree species indicates clear correlations. An additional investigation has revealed remarkable difference in the complex resistivity spectra between oil bearing and non-oil bearing sandal wood. This result and the relations between electrical parameters and structural parameters of wood indicate the prospective potential of low-frequency impedance spectroscopy.
One of the main problems in the assessment of the operability, stability and contamination potential of tailings facilities is the lack of data on subsurface materials, properties and structures. One key task in the use of geophysics is the selection of the proper methods for a given site/problem combination. Interpretation of the acquired and processed physical data (e.g. electrical resistivity distribution) into something useful for site assessment (e.g. contamination distribution) is another. In the TAILSAFE project (funded by the European Commission) we have worked with partners on the use of geophysics for tailings facilities inspection. DC and complex resistivity, ground penetrating radar, and spectral analysis of surface waves and multichannel analysis of surface waves have been used on dams and beaches. In most cases, our methods provided useful information on the subsurface structure, but the translation of geophysical values into geotechnical or other parameters is still challenging.
Der vorliegende Bericht ist der 2.Teil eines Gesamtberichtes und schildert ausführlich die im Kontext des BAM-Innovationsoffensive-Projektes „Chemische Brandspurenanalytik“ durchgeführten Untersuchungen und fasst die gewonnenen analytischen Erkenntnisse zusammen. Der gesamte Bericht gliedert sich in drei Teile. Der erste Teil beinhaltet den Aufbau, die Durchführung und die brandtechnologische Auswertung der durchgeführten Raumbrandversuche, während in dem hier vorliegenden Teil die analytischen Methoden zum Nachweis des Brandbeschleunigers in den Brandrückständen vorgestellt und ausgewertet werden. Die Beurteilung von Brandspuren und daraus abgeleitet die Rekonstruktion eines Brandverlaufes beruhen auch auf der präzisen chemischen Analyse der Brandprodukte. Im Rahmen dieses Projektes wurde eine innovative Methodik entwickelt, wie verfügbare Analysetechniken in geeigneter Weise kombiniert werden können, um aus festen, flüssigen und gasförmigen Brandrückständen Rückschlüsse auf den Brandverlauf ziehen zu können. Neben der Untersuchung von Proben von realen Brandorten wurden verschiedene wohnungstypische Materialien unter Laborbedingungen unterschiedlichen Brandszenarien unterworfen. Die dabei entstehenden Brandgase, Aerosole sowie der verbleibende Brandrückstand wurden durch geeignete analytische Verfahren analysiert, um mögliche Brandursachen beurteilen zu können. Der Schwerpunkt dieses Berichtes liegt in dem Nachweis von Brandbeschleunigern. Es zeigte sich, dass mittels der Kombination aus HS-SPME-GC-MS sowohl in den festen Brandrückständen, als auch in den Kondensaten Brandbeschleuniger eindeutig und verlässlich nachgewiesen werden können. Anhand von 5 verschiedenen Zimmerbrandversuchen wurde der Einfluss von Brandbeschleunigern auf den Brandverlauf experimentell untersucht. Es wurden verschiedene brandtechnologische Kennwerte, wie der Massenverlust des gesamten Brandraums, Brandraumtemperaturen, die Wärmefreisetzungen sowie die Rauchgasemissionen ermittelt und beurteilt. Die Rauchgasanalyse erfolgte im Schlot, im Brandraum sowie in der Brandraumöffnung mittels Fourier Transformierte Infrarot-FTIR-Spektroskopie. Neben diesen brandtechnologischen Untersuchungen, die im Bericht Teil 1 enthalten sind, erfolgten auch chemisch-analytische Untersuchungen nach dem Brand, mit dem Ziel, den eingesetzten Brandbeschleuniger nachzuweisen. Im Anschluss an die jeweiligen Zimmerbrandversuche wurden verschiedene Brandrückstandsproben aus dem Brandschutt, Wischproben von den Wänden und den übriggebliebenen Gegenständen genommen und mit Hilfe einer entwickelten HS-SPME-GC-MS-Methode (Headspace-Solid Phase Micro Extraction-Gas Chromatographie-Massenspekrometrie) in Hinblick eines möglichen Brandbeschleunigernachweis analysiert.