Filtern
Erscheinungsjahr
Dokumenttyp
- Beitrag zu einem Tagungsband (20)
- Zeitschriftenartikel (19)
- Vortrag (17)
- Beitrag zu einem Sammelband (4)
- Sonstiges (2)
- Buchkapitel (1)
- Dissertation (1)
- Posterpräsentation (1)
Schlagworte
- Radar (24)
- Zerstörungsfreie Prüfung (13)
- Ground penetrating radar (7)
- Stahlbeton (6)
- Ultraschall (6)
- Zerstörungsfreie Prüfung im Bauwesen (6)
- Concrete (5)
- Non-destructive testing (5)
- GPR (3)
- Ground penetrating radar (GPR) (3)
Organisationseinheit der BAM
- 8 Zerstörungsfreie Prüfung (7)
- 8.2 Zerstörungsfreie Prüfmethoden für das Bauwesen (7)
- 7 Bauwerkssicherheit (4)
- 8.6 Faseroptische Sensorik (3)
- 2 Prozess- und Anlagensicherheit (2)
- 2.4 Prüfung und Bewertung von Explosivstoffen/Pyrotechnik (2)
- 2.5 Konformitätsbewertung Explosivstoffe/Pyrotechnik (2)
- 7.4 Baustofftechnologie (2)
- 7.1 Baustoffe (1)
- 7.2 Ingenieurbau (1)
Eingeladener Vortrag
- nein (17)
Research and Development in Non-Destructive Testing in Civil Engineering at BAM has de-veloped over more than two decades. Highlights of present research are ultrasound phase array probes, ground penetrating radar applications for the assessment of existing structures and Laser Induced Breakdown Spec-troscopy (LIBS) to determine which chemical elements on the surface of a specimen are. RFID sensor devel-opments for wireless moisture monitoring and data fusion for the combined analysis of sensor data are fast developing areas. In addition, a selection of application cases is briefly described.
Die drei Beispiele zerstörungsfreier Prüfungen an Spannbetonbrücken zeigen unterschiedliche Problemstellungen und deren Lösung mit unterschiedlichen Ansätzen.
Allen drei Beispielen gemeinsam ist die Verwendung kommerzieller Geräte. Diese werden von verschiedenen Anbietern bereitgestellt. Eine weitere Gemeinsamkeit ist, dass die Grundgeräte durch zusätzliche Maßnahmen ergänzt. Erst dann ist der gewünschte Untersuchungserfolg sicher gestellt.
Im ersten Beispiel wurde die vom Auftraggeber geforderte Präzision dadurch erreicht, dass systematische Voruntersuchungen stattfanden. Die Übertragung der Lokalisierung direkt auf die Betonoberfläche stellte sicher, dass keinen Informationsverluste an die nachfolgenden Aufgaben auftraten.
Das zweite Beispiel zeigt den Nutzen von Automatisierung und Kombination von Verfahren. Damit können dem Auftraggeber die notwendigen Angaben über Einbauteile mit großer Detaitreue und leicht verständlicher Visualisierung aufbereitet werden. Der abschließende Bericht zeigt, wie vorhandene Auswertungen sinnvoll durch noch in der Forschung befindliche Ansätze bereichert werden.
Insgesamt ist die zerstörungsfreie Prüfung in der Lage, an Brücken preisrelevante Fragestellungen zu lösen. Voraussetzung hierfür ist eine sorgfältig geplante Vorgehensweise und ein sicheres Verständnis der Grundlage der eingesetzten Geräte und Auswertungsschritte.
Dunkelfärbung der Betonfahrbahndecke im AKR-Kontext - Ursachenanalyse mit innovativer Prüftechnik
(2018)
Die AKR-Schadensevolution von Betonfahrbahndecken ist in der Anfangsphase durch eine Dunkelfärbung der Oberfläche im Fugenbereich gekennzeichnet. Es wird vermutet, dass eine erhöhte Durchfeuchtung der Betonrandzone ursächlich für diese Erscheinung ist. Vor diesem Hintergrund wurde exemplarisch eine Fahrbahnplatte eines repräsentativen Bundesautobahnabschnitts systematisch mit verschiedenartiger zerstörungsfreier Prüftechnik vor Ort untersucht. Die Ergebnisse der zunächst erfolgten großflächigen Durchmusterung mit Radar zeigen, dass in den Bereichen mit einer Dunkelfärbung der Betonfahrbahndecke erhöhte Laufzeiten der Radarimpulse zwischen der
Oberfläche und der Rückseite der Betonfahrbahndecke auftreten, was auf eine erhöhte integrale Durchfeuchtung der Betonfahrbahndecke schließen lässt. Vertiefend durchgeführte NMR-Feuchtemessungen in der Betonrandzone zeigen eine gute Korrelation zwischen erhöhtem Feuchtegehalt und der dunkel gefärbten Fahrbahnoberfläche. Die Ergebnisse beider zerstörungsfreien Prüfmethoden lassen den Schluss zu, dass die Betonfahrbahndecke in der Nähe des Fugenkreuzes eine höhere Durchfeuchtung als im Bereich der Querscheinfuge aufweist. Die geringste Durchfeuchtung besitzt die Betonfahrbahndecke in der Plattenmitte. Die mit den zerstörungsfreien Prüfverfahren ermittelten Befunde stimmen prinzipiell gut mit den punktuell mittels Darr-Wäge-Verfahren an Bohrmehlproben gewonnenen Ergebnissen überein.
Estimation of ground penetrating radar's wave velocity in materials is a critical step to accurately estimate depth of embedded line objects in concrete structures, and wetness of material. Errors of velocity are defined as the deviations between the velocities obtained in various oblique angles and those obtained in the traverse normal to the object orientation in a common offset antenna setting. In this paper, we quantified and corrected the errors of such estimation. GPR traverses were designed to travel in various oblique angles θ (90°, 75°, 60° and 45°) relative to the steel bars at 5 cover depths (55 mm, 85 mm, 115 mm, 145 mm and 175 mm). GPR wave velocity at any position within the lateral detection range of steel bars was measured with simple trigonometry in a semi-automated in-house program. It was found that reduction of oblique angles (i.e. θ<90°) causes flatter hyperbolic reflections and the associated errors of velocity can be as much as 30% in the case of an oblique angle 45° before correction. Such errors were corrected after re-scaling the horizontal travel distance with a multiplication factor of sin θ.
Building stones are porous media and they can deteriorate through moisture ingress and secondary damage such as crystallization of soluble salts. Not only is this due to the increasing number of flood events in the past years but also structural damages of houses from activity such as leakage or rising moisture (groundwater) are the main causes. The potential benefit of several nondestructive testing methods to assess water damage in building stone has been studied in a field-scale experiment. Three testing walls made of fired clay brick, sandstone, and spongilite were flooded and their drying behavior monitored using infrared thermography, complex resistivity, ground penetrating radar, and ultrasonics. The results were compared to the average moisture content determined by gravimetric weighing of the specimens. Qualitatively, the results of the different nondestructive testing methods matched well. But in terms of quantitative data, some scatter was observed and the results should be viewed with care. Collecting time-consuming calibration data would help to overcome this problem, but especially when dealing with historic building structures, this is not always possible in practice.
Positioning accuracy of an automatic scanning system for GPR measurements on concrete structures
(2012)
Air voids in concrete like honeycombs are one of the major concerns regarding quality assurance for the construction of infrastructure buildings like bridges or tunnels. This paper shows that voids in reinforced concrete walls or slabs can be detected by two standard ground coupled GPR antennas in transmission mode using a two-side zero-offset profiling configuration like in borehole radar applications. For the detection of voids only the amplitudes of the direct wave in transmission mode are evaluated. Even when the depth of the void can not be detected in this configuration, the major advantage of the zero-offset profiling in transmission mode is a lower interference with the surrounding reinforcement compared to a regular one-side reflection profiling. The capability of the two-side zero-offset profiling is demonstrated on a test specimen with a set of polystyrene balls of two different sizes representing voids like honeycombs in concrete. GPR measurements are realized by an automated scanning system in order to allow for a synchronous movement of the antennas. In transmission mode voids can be detected at greater depths compared to reflection mode, since the travel path of the direct wave is half as long. Another characteristic of the transmission mode is that the direct wave through the air voids is faster and arrives earlier than the direct wave in the surrounding concrete. Hence it can be separated from the strong reflection of the reinforcement. Finally the measurements in transmission mode are less sensitive to the antenna frequency and polarization than in reflection mode.
The concreting of prefabricated concrete structures can lead to insufficient bonding or even to remaining cavities. Honeycombs (aggregate clusters without cement) represent potential weakening of the structure and need to be detected non-destructively. In our study we tested the capability of ground penetrating radar (GPR)techniques for this purpose. We applied GPR in reflection mode and zero-offset profiling (ZOP) Transmission mode on a precast concrete twin wall with built-in honeycombs. GPR measurements were performed as twochannel measurement with ground coupled antennas with centre frequencies of 1.5 GHz and 2.6 GHz mounted to an automated scanner system.
Our findings show that ZOP transmission measurements are a more efficient method to detect voids in reinforced concrete structures compared to reflection mode measurements. This holds for both the effort needed for the measurement and the evaluation as well as the validity of the data. Honeycombs (basically representing voids) are usually characterized by strongly reduced amplitudes and earlier arrivals of the transmitted wave.