Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (29)
- Posterpräsentation (14)
- Vortrag (5)
- Beitrag zu einem Tagungsband (2)
Schlagworte
- Fluorescence (14)
- Nanoparticles (9)
- Nanoparticle (6)
- Quantum yield (6)
- NIR (5)
- Dye (4)
- Microparticles (3)
- AIE (2)
- Brightness (2)
- Cancer (2)
Organisationseinheit der BAM
Eingeladener Vortrag
- nein (5)
Many applications of nanometer- and micrometer-sized particles include their surface functionalization with linkers, sensor molecules, and analyte recognition moieties like (bio)ligands. This requires knowledge of the chemical nature and number of surface groups accessible for subsequent coupling reactions. Particularly attractive for the quantification of these groups are spectrophotometric and fluorometric assays, which can be read out with simple instrumentation. In this respect, we present here a novel Family of cleavable spectrophotometric and multimodal reporters for conjugatable amino and carboxyl surface groups on nano- and microparticles. This allows determination of particle-bound labels, unbound reporters in the supernatant, and reporters cleaved off from the particle surface, as well as the remaining thiol groups on particle, by spectrophotometry and inductively coupled optical emission spectrometry (32S ICP-OES). Comparison of the performance of these cleavable reporters with conductometry and conventional labels, utilizing changes in intensity or Color of absorption or emission, underlines the analytical potential of this versatile concept which elegantly circumvents Signal distortions by scattering and Encoding dyes and enables straightforward validation by method comparison.
Molecular imaging of inflammatory lung diseases, such as asthma, has been limited to date. The recruitment of innate immune cells to the airways is central to the inflammation process. This study exploits these cells for imaging purposes within the lung, using inhaled polystyrene nanoparticles loaded with the near-infrared fluorescence dye Itrybe (Itrybe-NPs). By means of in vivo and ex vivo fluorescence reflectance imaging of an ovalbumin-based allergic airway inflammation (AAI) model in hairless SKH-1 mice, we show that subsequent to intranasal application of Itrybe-NPs, AAI lungs display fluorescence intensities significantly higher than those in lungs of control mice for at least 24 h. Ex vivo immunofluorescence analysis of lung tissue demonstrates the uptake of Itrybe-NPs predominantly by CD68+CD11c+ECF-L+MHCIIlow cells, identifying them as alveolar M2 macrophages in the peribronchial and alveolar areas. The in vivo results were validated by confocal microscopy, overlapping tile analysis, and flow cytometry, showing an amount of Itrybe-NP-containing macrophages in lungs of AAI mice significantly larger than that in controls. A small percentage of NP-containing cells were identified as dendritic cells. Flow cytometry of tracheobronchial lymph nodes showed that Itrybe-NPs were negligible in lung draining lymph nodes 24 h after inhalation. This imaging approach may advance preclinical monitoring of AAI in vivo over time and aid the investigation of the role that macrophages play during lung inflammation. Furthermore, it allows for tracking of inhaled nanoparticles and can hence be utilized for studies of the fate of potential new nanotherapeutics.
The surface modification of nanometer- and micrometer-sized particles and planar substrates with polyethylene glycol (PEG) ligands of varying length is a very common strategy to tune the hydrophilicity and biocompatibility of such materials, minimize unspecific interactions, improve biofunctionalization efficiencies, and enhance blood circulation times. Nevertheless, simple methods for the quantification of PEG ligands are comparatively rare. Here, we present a new concept for the quantification of PEG ligands for maleimide-functionalized PEG molecules and the determination of PEG coupling efficiencies, exploiting the quantitative reaction of maleimide with ʟ-cysteine, and the subsequent determination of the unreacted thiol with the photometric Ellman's test. This is shown for heterobifunctional PEG spacers of varying length and amino-functionalized polystyrene nanoparticles (PS NP) without and with differently charged encoding dyes. The reaction of ʟ-cysteine with the Ellman's reagent was monitored photometrically and with electrospray ionization time-of-flight mass spectrometry (ESI-TOF-MS) to derive the reaction mechanism and to obtain the stoichiometry factor for ʟ-cysteine quantification. Mass balances and quantification of ʟ-cysteine via its sulfur concentration using elemental analysis and inductively coupled plasma mass spectrometry (ICP-MS) confirmed the accuracy and reliability of this approach that can be extended to other surface groups and ligands.
A series of twelve 3-piperazinyl propenylidene indolone merocyanines was synthesized in a one-pot fashion using a consecutive three-component insertion-coupling-Michael addition sequence. Physicalorganic treatment of the absorption data of a consanguineous series of this library allows semiquantitative Linear Free Energy Relationships (LFERs) to be established and confirmation of the positive Absorption solvatochromicity. All Boc-substituted piperazinyl merocyanines display aggregation induced Emission (AIE), which was corroborated for two solvent systems. In particular, crystallization-induced Emission enhancement (CIEE) induced by ultrasonication could be shown for a model chromophore by confocal laser scanning microscopy (CLSM).
Nanometer- and micrometer-sized particles are of increasing importance for a wide range of applications in the material and life sciences. This includes carriers for, e.g., drugs as well as dye molecules for use as multichromophoric reporters for signal enhancement in optical assays, platforms for DNA sequencing, and the fabrication of nanosensors and targeted probes for bioimaging studies.
Application-relevant properties of such particles include their size (and size distribution), shape, colloidal stability, biocompatibility, and ease of subsequent functionalization, e.g., with linkers, sensor molecules, and targeting ligands. The latter requires knowledge of the number of groups effectively accessible for subsequent coupling reactions and hence, selective and sensitive methods of analysis, which can be ideally employed for the characterization of a broad variety of particle systems independent of their optical properties, i.e., scattering or the presence of encoding dyes. For product control, robust, reliable and fast methods performable with inexpensive equipment are prefered.
In this respect, we studied a variety of conventional labels for optical readout, utilizing changes in intensity and/or color of absorption and/or emission. In addition, we developed a platform of cleavable and multimodal labels for optical assays which consist of a cleavable linker and an optically active reporter moiety. In contrast to conventional reporters measured directly at the particle surface, which are prone to signal distortions by scattering and encoding dyes, these cleavable labels can be detected colorimetrically or fluorometrically both bound at the particle surface and after quantitative cleavage of the linker in the transparent supernatant. Moreover, they enable straightforward validation by method comparison with elemental analysis, ICP-OES or ICP-MS.
Here, we present representative examples of newly synthesized cleavable labels and their application for the quantification of amino, thiol and carboxy surface groups on different nanomaterials and compare these results with measurements using conventional optical labels.
3-Aminovinylquinoxalines are readily accessible from (hetero)aryl glyoxylic acids or heterocyclic π-nucleophiles by consecutive four- and fivecomponent syntheses in the sense of an activation-alkynylation-cyclocondensation-addition sequence or glyoxylation-alkynylation-cyclocondensation-addition sequence in good yields. The title compounds are highly fluorescent with pronounced emission solvatochromicity and protochromic fluorescence quenching. Time-resolved fluorescence spectroscopy furnishes radiative and nonradiative fluorescence decay rates in various solvent polarities. The electronic structure is corroborated by DFT and TD-DFT calculations rationalizing the observed spectroscopic effects.
Coumarin-rhodamine hybrids-novel probes for the optical measurements of viscosity and polarity
(2017)
A comprehensive systematic study of Absorption and fluorescence properties in solvents of varying viscosity and polarity of three novel and red-emitting coumarin-rhodamine hybrid derivatives with differences in the rigidity of their substituents is presented. This includes ethanol-polyethylene glycol, toluene-polyethylene glycol, and tolueneparaffin mixtures. Moreover, protonation-induced effects on the spectroscopic properties are studied. A viscosity-induced emission enhancement was observed for all coumarin-rhodamine hybrid derivatives. MCR2 bearing a julolidine donor showed the expected low sensitivity to viscosity whereas MCR3 with its freely rotatable diphenylamino Substituent revealed a particularly pronounced sensitivity to this parameter.
Moreover, MCR2 shows an enhancement in Emission in the open, i.e., protonated form in conjunction with a largely Stokes shift fluorescence in the deep red spectral region. This enables the application of these dyes as viscosity sensors and as far red emitting pH-sensitive probes.
Photoluminescence techniques are amongst the most widely used Tools in the life sciences, with new and exciting applications in medical diagnostics and molecular Imaging continuously emerging. Advantages include their comparative ease of use, unique sensitivity, non-invasive character, and potential for Multiplexing, remote sensing, and miniaturization. General drawbacks are, however, signals, that contain unwanted wavelength- and polarization contributions from Instrument-dependent effects, which are also time-dependent due to aging of Instrument-components, and difficulties to measure absolute flourescence entensities. Moreover, scattering Systems require Special measurement geometries and the interest in new optical Reporters with Emission > 1000 nm strategies for reliable measurements in the second diagnostic for the comparison of material Performance and the rational designg of new flourophores with improved properties.
Here, we present strategies to versatile method-adaptable liquid and solid flourescence Standards for different flourescence paramters including traceable Instrument calibration procedures and the design of integrating spere setups for the absolute measurements of emission spectra and Quantum yields in the wavelength Region of 350 to 1600 nm. Examples are multi-Emitter glasses, spectral flourescence Standards, and quantum yield Standards for the UV/vis/NIR.
Comparing the performance of molecular and nanoscale luminophores and luminescent microand nanoparticles and estimating achievable signal amplitudes and limits of detection requires a standardizable intensity scale. This initiated the development of the relative MESF (number of molecules of equivalent soluble fluorochromes) and ERF (equivalent reference fluorophores) scales for flow cytometry and fluorescence microscopy. Both intensity scales rely on fluorescence intensity values assigned to fluorescent calibration beads by an intensity comparison to spectrally closely matching fluorophore solutions of known concentration using a spectrofluorometer. Alternatively, the luminophore or bead brightness (B) can be determined that equals the product of the absorption cross section (σa) at the excitation wavelength (σa(λex)) and the photoluminescence quantum yield (Φpl).
Thereby, an absolute scale based on fundamental and measurable spectroscopic properties can be realized which is independent of particle size, material, and luminophore staining or labeling density and considers the sensitivity of the optical properties of luminophores to their environment. Aiming for establishing such a brightness scale for light-scattering dispersions of luminescent particles with sizes exceeding a few ten nanometers, we demonstrate how the brightness of quasi-monodisperse 25 nm, 100 nm, and 1 μm sized polystyrene particles (PSP), loaded with two different dyes in varying concentrations, can be obtained with a single custom-designed integrating sphere setup that enables the absolute determination of Φpl and transmittance and diffuse reflectance measurements. The resulting Φpl, σa(λex), imaginary parts of the refractive index, and calculated B values of these samples are given in dependence of the number of incorporated dye molecule per particle. Finally, a unitless luminescence efficiency (LE) is defined allowing for the direct comparison of luminescence efficiencies of particles with different sizes.