Filtern
Erscheinungsjahr
Dokumenttyp
Schlagworte
- CCQM (3)
- CIGS (3)
- EPMA (2)
- Hydrogen detection (2)
- Long-term measurement (2)
- Low energy sensor (2)
- Transmission function (2)
- X-ray photoelectron spectroscopy (2)
- XPS (2)
- AES (1)
Organisationseinheit der BAM
The prediction of the properties of the materials used in the operation of components is of enormous importance, in order to accelerate the development process of new components. To evaluate new materials in terms of their performance (in a component), the development of new innovative methods is necessary. These methods can also be summarized under the term lab-to-field or materials – upscaling, meaning materials being characterised in a laboratory and their properties being upscaled to the component performance by means of e.g. simulation. i-TRIBOMAT is a EU funded project (H2020, GA Nr. 814494) aiming at building an Open Innovation Test Bed for tribological material characterization and offering corresponding services from tribological characterization of new materials to simulation models for predicting the performance of industrial components. By bundling the infrastructure, know-how for characterization and building a digital platform, i-TRIBOMAT becomes the world’s largest open innovation test bed for tribological material characterization.
We report the results of a Versailles Project on Advanced Materials and Standards interlaboratory study on the intensity scale calibration of x-ray photoelectron spectrometers using low-density polyethylene (LDPE) as an alternative material to gold, silver, and copper. An improved set of LDPE reference spectra, corrected for different instrument geometries using a quartz-monochromated Al Kα x-ray source, was developed using data provided by participants in this study. Using
these new reference spectra, a transmission function was calculated for each dataset that participants provided. When compared to a similar calibration procedure using the NPL reference spectra for gold, the LDPE intensity calibration method achieves an absolute offset of ∼3.0% and a systematic deviation of ±6.5% on average across all participants. For spectra recorded at high pass energies (≥90 eV), values of absolute offset and systematic deviation are ∼5.8% and ±5.7%, respectively, whereas for spectra collected at lower pass energies (<90 eV), values of absolute offset and systematic deviation are ∼4.9% and ±8.8%, respectively; low pass energy spectra perform worse than the global average, in terms of systematic deviations, due to diminished count rates and signal-to-noise ratio. Differences in absolute offset are attributed to the surface roughness of the LDPE induced by sample preparation. We further assess the usability of LDPE as a secondary reference material and comment on its performance in the presence of issues such as variable dark noise, x-ray warm up times, inaccuracy at low count rates, and underlying spectrometer problems. In response to participant feedback and the results of the study, we provide an updated LDPE intensity calibration protocol to address the issues highlighted in the interlaboratory study. We also comment on the lack of implementation of a consistent and traceable intensity calibration method across the community of x-ray photoelectron spectroscopy (XPS) users and, therefore, propose a route to achieving this with the assistance of instrument manufacturers, metrology laboratories, and experts leading to an international standard for XPS intensity scale calibration.
The lead authors failed to name two collaborators as co-authors. The authors listed should include:
Miss Claudia L. Compean-Gonzalez (ORCID:
0000-0002-2367-8450) and Dr. Giacomo Ceccone (ORCID:
0000-0003-4637-0771).
These co-authors participated in VAMAS project A27, provided data that were analyzed and presented in this publication (and supporting information), and reviewed the manuscript before submission.
CCQM key comparison K-129 for the quantitative analysis of Cu(In,Ga)Se2 (CIGS) films has been performed by the Surface Analysis Working Group (SAWG) of the Consultative Committee for Amount of Substance (CCQM). The objective of this key comparison is to compare the equivalency of the National Metrology Institutes (NMIs) and Designated Institutes (DIs) for the measurement of mole fractions of Cu, In, Ga and Se in a thin CIGS film. The measurand of this key comparison is the average mole fractions of Cu, In, Ga and Se of a test CIGS alloy film in the unit of mole fraction (mol/mol). Mole fraction with the metrological unit of mol/mol can be practically converted to atomic fraction with the unit of at%.
In this key comparison, a CIGS film with certified mole fractions was supplied as a reference specimen to determine the relative sensitivity factors (RSFs) of Cu, In, Ga and Se. The mole fractions of the reference specimen were certified by isotope dilution - inductively coupled plasma/mass spectrometry (ID-ICP/MS) and are traceable to the SI. A total number counting (TNC) method was recommended as a method to determine the signal intensities of the constituent elements acquired in the depth profiles by Secondary Ion Mass Spectrometry (SIMS), X-ray Photoelectron Spectroscopy (XPS) and Auger Electron Spectroscopy (AES). Seven NMIs and one DI participated in this key comparison. The mole fractions of the CIGS films were measured by depth profiling based-SIMS, AES and XPS. The mole fractions were also measured by non-destructive X-Ray Fluorescence (XRF) Analysis and Electron Probe Micro Analysis (EPMA) with Energy Dispersive X-ray Spectrometry (EDX).
In this key comparison, the average degrees of equivalence uncertainties for Cu, In, Ga and Se are 0.0093 mol/mol, 0.0123 mol/mol, 0.0047 mol/mol and 0.0228 mol/mol, respectively. These values are much smaller than that of Fe in a Fe-Ni alloy film in CCQM K-67 (0.0330 mol/mol). This means that the quantification of multi-element alloy films is possible by depth profiling analysis using the TNC method.
Crack detection in steel bars at high surface temperatures is a critical problem in any manufacturing industry. Surface breaking cracks are the major problems during the billet casting. Many NDT techniques are proven its capability in crack detection at room temperature. Here, we are demonstrating the possibility of exposure of cracks using laser line thermography at higher surface temperatures (up to 600 °C). A continuous-wave (CW) laser is used to excite the sample kept at higher surface temperatures. The temperature distribution over the sample due to the laser line scanning is captured using a temperature calibrated infrared (IR) thermal camera. The response of the sample temperature in crack detection is investigated using a validated FE model. The impact of the oxide layer in crack detection is investigated by using two types of samples; one without any oxide layer and the second is with the oxide layer. The influence of laser power in the detection of defects at high temperatures is studied. 3D numerical models were developed for the cases; when the sample is with oxide layer and without any oxide layer for a better understanding of physics. The surface temperature rise due to laser heating is higher for the scaled sample compared to the no-scale sample. The presence of the oxide layer above the parent metal will reduce the reflectivity of the surface. Lower reflectivity will lead to increased absorption of incident energy so that the surface temperature rise will be higher than the surface with no scale. Thermal contrast linearly depends on laser power, which means higher laser power will increase the defect detectability even at a higher surface temperature.
Infolge der Betriebsbeanspruchung unterliegen Eisenbahnschienen an
ihrer Fahrkante sog. Rollkontakt-Ermüdung. Diese entsteht bevorzugt in Bögen
durch eine Kaltverformung des Schienenstahls und zeigt sich anfänglich in einer erhöhten
Verfestigung des kontaktbeanspruchten Oberflächenbereichs. Im weiteren
Verlauf entstehen zahlreiche, flach in das Schieneninnere verlaufende Risse sog.
Head Checks. Diese Risse neigen ab einem gewissen Stadium dazu, in das Innere
der Schiene abzukippen, was im Endstadium zu einem Schienenbruch führen kann.
Seit einigen Jahren wird in Deutschland bei der DB AG das Wirbelstromverfahren
erfolgreich zur zerstörungsfreien Prüfung der Schädigungstiefe von Head Checks
eingesetzt. Hiermit wurde u. A. angestrebt, zuverlässige Planungsgrößen für den
Einsatz von Instandhaltungsmaßnahmen zu erhalten, durch deren gezielten Einsatz
ein weiteres Risswachstum wirkungsvoll unterbunden werden kann. Bereits bei einem
der ersten systematischen Einsätze der Wirbelstromprüfung an einer Bogenstrecke
mit hohem Betriebsaufkommen wurde auffällig, dass die Ermüdungsrisse
nicht gleichmäßig entlang des Bogens verteilt auftraten, sondern sich auf kurze Distanzen
Anhäufungen von Rissbefall mit intakten, unbefallenen Abschnitten abwechselten.
Solch wellenförmiges Auftreten von Head Checks wurde auch in den nachfolgenden
Prüfergebnissen der Wirbelstromprüfung vielerorts beobachtet. Aus der
Literatur war bekannt, dass sich die Ermüdungsrisse bevorzugt in verfestigten Materialzonen
bilden. Mit Hilfe von Härtemessungen konnte an verlegten und befahrenen
Schienen gezeigt werden, dass die unbefallenen Zonen etwa die Grundhärte des
Schienenwerkstoffes aufwiesen, während die mit Ermüdungsrissen befallenen Zonen
um ca. 10 25% erhöhte Härtewerte aufwiesen. Die Wirbelstromprüfung reagiert
sehr empfindlich auf Veränderungen der Materialeigenschaften. Somit lassen
sich Verfestigungen der o. g. Art leicht auch ohne jedes Vorhandensein von Ermüdungsrissen
bereits nachweisen. Im Zuge einer längerfristigen Beobachtung einer
neu gebauten Strecke konnte herausgefunden werden, dass sich nach einer gewissen
Betriebszeit wellenförmig verteilte Zonen mit Prüfsignalen, die auf Verfestigungen
schließen lassen auftraten. Im weiteren zeitlichen Ablauf bildeten sich Ermüdungsrisse
tatsächlich in den vorher bestimmten Stellen mit Verfestigung, während die
Zonen ohne diese Prüfsignale weitgehend rissfrei blieben. Diese Ergebnisse zeigen,
dass die Wirbelstromprüfung das Potential besitzt, mögliche Orte der Entstehung
von Ermüdungsrissen in einem extrem frühzeitigen Stadium nachzuweisen.
A pilot study for the quantitative surface analysis of multi-element alloy films has been performed by the Surface Analysis Working Group (SAWG) of the Consultative Committee for Amount of Substance (CCQM). The aim of this pilot study is to ensure the equivalency in the measurement capability of national metrology institutes for the quantification of multi-element alloy films. A Cu(In,Ga)Se2 (CIGS) film with non-uniform depth distribution was chosen as a representative multi-element alloy film. The atomic fractions of the reference and the test CIGS films were certified by isotope dilution - inductively coupled plasma/mass spectrometry. A total number counting (TNC) method was used as a method to determine the signal intensities of the constituent elements, which are compared with their certified atomic fractions. The atomic fractions of the CIGS films were measured by various methods, such as Secondary Ion Mass Spectrometry (SIMS), Auger Electron Spectroscopy (AES), X-ray Photoelectron Spectroscopy (XPS), X-Ray Fluorescence (XRF) analysis and Electron Probe Micro Analysis (EPMA) with Energy Dispersive X-ray Spectrometry (EDX). Fifteen laboratories from eight National Metrology Institutes (NMIs), one Designated Institute (DI) and six non-NMIs participated in this pilot study. Although the average atomic fractions of 18 data sets showed rather poor relative standard deviations of about 5.5 % to 6.8 %, they were greatly improved to about 1.5 % to 2.2 % by excluding 5 strongly deviating data sets from the average atomic fractions. In this pilot study, the average expanded uncertainties of SIMS, XPS, AES, XRF and EPMA were 3.84%, 3.68%, 3.81%, 2.88% and 2.90%, respectively. These values are much better than those in the key comparison K-67 for composition of a Fe-Ni alloy film. As a result, the quantification of CIGS films using the TNC method was found to be a good candidate as a subject for a CCQM key comparison.
The stabilization of crystal phases and nanostructured morphologies is an essential topic in application-driven design of mesoporous materials. Many applications, e.g. catalysis, require high temperature and humidity. Typical metal oxides transform under such conditions from a metastable, low crystal-line material into a thermodynamically more favorable form, i.e. from ferrihy-drite into hematite in the case of iron oxide. The harsh conditions induce also
a growth of the crystallites constituting pore walls, which results in sintering and finally collapse of the porous network. Herein, a new method to stabi-lize mesoporous templated metal oxides against sintering and pore collapse is reported. The method employs atomic layer deposition (ALD) to coat the internal mesopore surface with thin layers of either alumina or silica. The authors demonstrate that silica exerts a very strong influence: It shifts hematite formation from 400 to 600 °C and sintering of hematite from 600 to 900 °C.
Differences between the stabilization via alumina and silica are rationalized by a different interaction strength between the ALD material and the ferrihydrite film.
The presented approach allows to stabilize mesoporous thin films that require a high crystallization temperature, with submonolayer quantity of an ALD material, and to apply mesoporous materials for high temperature applications.
A silicon MIS-structure prepared with thin layers of the super-ionic conductor LaF3 and Pd is used to detect hydrogen. The sensor is able to detect hydrogen in a concentration range from below one ppm to the lower flammable limit in air which is 4 vol.-%. The chip operates at room temperature which results in an extremely low energy consumption compared to other hydrogen sensors. Only once per day a short heating pulse is necessary to reactivate the sensor chip. In cooperation with the BAM, a long-term experiment was carried out. The duration of the measurement was about three months, with a hydrogen exposure every two weeks. The sensor signal remained stable over the measured period.