Two synthetic isotope mixtures for the calibration of sulfur isotope amount ratio measurements were gravimetrically prepared from high purity Ag2S materials enriched in 32S, 33S, and 34S. The mixtures were made so as to closely resemble the (natural) isotopic composition of the materials to be calibrated. This allowed a totally independent evaluation, on the same samples, of the relative combined uncertainty of: (a) the procedure to perform direct measurements of the amount of substance ratios of gas isotopes in the redetermination of the Avogadro constant and (b) the gravimetric preparation procedure. The result of both procedures, mass spectrometry and gravimetry, agree to a relative uncertainty of 3 × 10-4 for sulfur amount ratio measurements of the major abundant isotopes. Thus it seems that a direct measurement of isotopic gas mixtures (e.g. of natural isotopic composition) is now possible for sulfurand probably also for other gaseous isotopeswithout necessarily having to rely on calibration by means of values provided by measurements of gravimetrically prepared isotope mixtures. However, synthetic mixtures may be needed for validation and verification purposes, in particular for quality assurance.
The present paper describes the certification of the amount content of Cd, Cr and Pb in two different polyethylene materials within the third phase of the Polyethylene Elemental Reference Material (PERM) project. The analytical procedure to establish the reference values for Cd, Cr and Pb amount contents in these materials is based on isotope dilution mass spectrometry used as a primary method of measurement. Cd and Pb were measured with inductively coupled plasma-mass spectrometry and Cr with positive thermal ionization-mass spectrometry. The decomposition of the polymer matrix was carried out using a high pressure asher. Reference values for amount content, traceable to the SI-system, have been obtained for these three elements in both of the polyethylene samples of PERM. For each of the certified amount content values an uncertainty budget was calculated using the method of propagation of uncertainties according to ISO and EURACHEM guidelines. The measurement procedures, as well as the uncertainty calculations, are described for all three elements. In order to keep the whole certification process as transparent as possible, the preparations of various reagents and materials as well as the sample treatment and blending are described in detail. The mass spectrometry measurements and the data treatment are also explained carefully. The various sources of uncertainty present in the procedure are displayed in the uncertainty budgets. The obtained combined uncertainties for the amount content values were less than 2% relative (k=1) for all investigated elements. The amount contents were in the ?mol/kg range, corresponding to mg/kg levels.