Eingeladener Vortrag
- nein (3)
Calibration of two commercially available glow discharge double focusing mass spectrometers, the VG 9000 and Element GD, is described using synthetic pin standards pressed from solution doped copper and zinc matrices. A special pressing die was developed for this purpose and optimal results were obtained with the highest possible pressures, i.e., 95 kN·cm- 2. This calibration approach permits the determination of trace element mass fractions down to µg·kg- 1 with small uncertainties and additionally provides traceability of the GD-MS results in the most direct manner to the SI (International System of Units). Results were validated by concurrent measurements of a number of compact copper and zinc certified reference materials. The impact of the sample pin cross-section (circular or square) was investigated with the use of a new pin-sample holder system for the Element GD. The pin-sample holder was designed by the manufacturer for pin-samples having circular cross-section; however, samples with square pin cross-section were also shown to provide acceptable results. Relative Sensitivity Factors for some 50 analytes in copper (VG 9000, Element GD) and zinc matrices (VG 9000) are presented. The field of applicability of GD-MS may be considerably extended via analysis of pin geometry samples based on their ease of preparation, especially with respect to the accuracy and traceability of the results and the enhanced number of analytes which can be reliably calibrated using such samples.
The International Temperature Scale of 1990 (ITS-90) is based on thermodynamic equilibrium states of ideally pure substances. The largest contribution to the uncertainty budgets of most metallic fixed points is the influence of impurities on the fixed-point temperature. Therefore, a traceable chemical analysis of the remaining impurities with small uncertainty is the basis of further progress. Further requirements are better knowledge of the phase diagrams at very low impurity contents, impurity segregation, and the quantification and correction of thermal effects during a fixed-point realization. In this article, current and future activities at PTB and BAM in order to develop improved metallic fixed-point cells of the ITS-90 are reviewed.