Novel agar-based test electrolytes are used to perform electrochemical corrosion investigations on ZnFe and ZnNi binary as well as ZnFeMo ternary zinc coatings. The objectives of the electrochemical investigations include the characterization of the corrosion behavior, the description of the protective effect of the coatings as well as the investigation of the layer formation and degradation under artificial aging. ZnFe and ZnFeMo coatings are applied with varying iron content as well as an additional passivation layer, respectively, to study the effect on corrosion resistance. The results show that the protective effect of the coatings is not negatively influenced by different iron contents or the addition of molybdenum. Additional passivation of the ZnFe-containing coatings by means of a passivating agent leads to a significant improvement in the protective effect. Artificial aging leads to slight degradation of the additional passivation layer whereas coatings without post-treatment enhance their protective effect by the formation of corrosion product layers.
Femtosecond laser pulses are close to industrial use. The advantages of ultrashort laser pulses for micromachining applications especially in the case of dielectric and biological samples down to pulse durations of 5 fs have been established. The current international standards of laser safety are primarily concerned with CW and pulsed lasers down to the nanosecond range. Therefore, human tissue and laser-protection equipment was investigated with respect to its resistance and protection performance for femtosecond laser illumination down to 30 fs. This included filter glasses for laser protection eyewear, polymer and textile materials used in curtains and guards. Bulk absorber filters can provide enough protection against laser radiation, give a sufficiently broad absorption spectrum. Materials are damaged more easily by femtosecond laser radiation. The need for sufficient spectral broadness as well as the different damage thresholds have to be included in international laser safety standards. This work should trigger the development of novel eye-protection devices that are lighter and ergonomically more acceptable than present commercial models.
The multi-pulse ablation threshold of barium borosilicate glass was measured using 30-fs pulses of a high repetition rate (1 kHz) laser system. The threshold fluence was found to decrease with increasing beam radius ranging from 20 to 400 m. Two existing models are applied by considering thermal accumulation and point defects, respectively .
On the damage behavior of dielectric films when illuminated with multiple femtosecond laser pulses
(2005)
The physical effects reducing the damage threshold of dielectric films when exposed to multiple femtosecond pulses are investigated.
The measured temperature increase of a Ta2O5 film scales exponentially with the pulse fluence. A polarized luminescence signal is observed that
depends quadratically on the pulse fluence and is attributed to twophoton excitation of self-trapped excitons that form after band-to-band
excitation. The damage fluence decreases with increasing pulse number, but is independent of the repetition rate from 1 Hz to 1 kHz at a constant
pulse number. The repetition rate dependence of the breakdown threshold is also measured for TiO2 , HfO2,
Al2O3, and SiO2 films. A theoretical model is presented that explains these findings.
Femto- and nanosecond laser ablation of polymethylmethacrylate (PMMA) and PMMA doped with a linear absorber was
investigated in the infrared spectral region. Ablation thresholds were determined and incubation phenomena were identified. The
degree of incubation was calculated employing a phenomenological model. The influence of the pulse duration on the
machining quality of the polymers was examined. The presence of an absorbing chromophore is not a prerequisite for a
controllable fs-laser structuring in contrast to the ns-treatment. Surface swelling always accompanied ablation.
Results of a round-robin experiment in multiple-pulse LIDT measurement with ultrashort pulses
(2004)
The influence of different laser pulse lengths on the removal of a polymer layer from metal substrates was investigated. As model systems, doped poly(methylmetacrylate) (PMMA) on titanium and tungsten substrates were selected.
The ablation threshold and irradiation spot morphology of titanium and tungsten were compared for femtosecond (fs) and nanosecond (ns) laser irradiation and different pulse numbers. Nanosecond laser treatment resulted in a non-homogeneous surface morphology for both titanium and tungsten substrates. Femtosecond irradiation of tungsten revealed a homogeneous ablation spot with little changes in the surface morphology. For titanium, the formation of columnar structures within the irradiation spot was observed.
Two different dopant concentrations were used for PMMA to achieve an equal linear absorption coefficient for the femto- and nanosecond laser wavelengths of 790 and 1064 nm. The best results were achieved for the removal of doped PMMA by femtosecond laser irradiation, where only a minimal modification of the metal surface was detected. In the case of nanosecond laser exposure, a pronounced change of the structure was observed, suggesting that damage-free cleaning of the selected metal may only be possible using femtosecond laser pulses. Different experimental parameters, such as laser fluence, pulse repetition rate and sample speed were also investigated to optimize the cleaning quality of doped PMMA from tungsten substrates with femtosecond laser pulses.
The laser ablation behaviour of ion-doped glass filter materials under irradiation with femtosecond laser pulses was investigated with respect to spot size and repetition rate. The damage threshold fluence of Schott BG18 depends on the size of the irradiated area. The effect is discussed in terms of a defect-site model.