Filtern
Dokumenttyp
- Beitrag zu einem Tagungsband (4) (entfernen)
Referierte Publikation
- nein (4)
Schlagworte
- Beton (2)
- Cracks (2)
- Ermüdung (2)
- Acoustic emission analysis (1)
- Digital image correlation (1)
- Energy (1)
- Failure (1)
- Grouted Connection (1)
- Grouted connections (1)
- Offshore (1)
Organisationseinheit der BAM
- 7 Bauwerkssicherheit (1)
- 7.1 Baustoffe (1)
- 7.2 Ingenieurbau (1)
- 7.4 Baustofftechnologie (1)
At present, Wind Turbine Generators (WTGs) operating in onshore and offshore wind farms are primary sources of renewable energy around the world. Cylindrical grouted sleeve connections are usually adopted in these WTG structures to connect the upper structure and foundation for ease of installation. These structures including grouted connections experience considerable adverse loading during their lifetimes. Settlements were reported inside similar connections used in energy structures especially oil and gas platforms, which were installed in last three decades. Thus, repair and rehabilitation of such connections in existing wind structures should also be planned ahead to keep them operating in the future. The nature of failure and crack generation in grouted connections are crucial prior to adopt a strengthening strategy. This pilot study is carried out to actualize the failure mechanism in the grouted connection, when subjected to axial loading. A novel reusable scaled cylindrical grouted connection with shear keys was designed and tested for its load bearing behaviour. The mechanical test was accompanied by classical measuring techniques (e.g. displacement transducer) as well as non-destructive measuring techniques (e.g. digital image correlation (DIC), acoustic emission analysis (AE)). The failure mechanism incorporating slippage of the shear keys and cracking of the grout was investigated. The capacity and applicability of such test mould were also discussed. The knowledge is expected to pave way towards repair of deteriorated grouted connections with similar geometry and failure pattern.
Remediation of Cracks Formed in Grouted Connections of Offshore Energy Structures under Static Loads
(2018)
The future energy demand necessitates the exploration of all potential energy sources both onshore and offshore. Global trend has shifted towards offshore energy, which can be obtained from either carbon intensive or renewable options, hence requiring structures such as rigs, platforms, and monopiles. Most of these structures adopt easily installable construction techniques, where lower foundation need to be connected with the super structure by mean of grouted composite joints. Generally, these composite connections have exterior sleeve, interior pile and infill grout. Being located in remote offshore conditions, connections can experience considerable adverse loading during their lifetimes. Degradations were reported inside similar connections, which were installed in last three decades. Besides, grouting in the offshore sites may often be proven difficult, which eventually leads to reduced capacity of connections in the long run. Thus, repair and rehabilitation of such connections should be planned ahead to minimize operational delays and costs in the future. This study aims at characterizing the nature of crack generation in grouted connections and thereby identifying the potential of repair using suitable repair material. Scaled grouted joints were manufactured using a novel mold, and connections were loaded under static load to visualize the main failure pattern. The failure mechanism and loading capacity are found compatible to previous results from earlier literature. Grouted connection was then repaired using cementitious injectable grout. The effectiveness of the repair system is also discussed.
Unter zyklischen Belastungen findet im Beton, wie bei anderen Materialien auch, ein Ermüdungsprozess statt. Im derzeitigen Erkenntnisstand zum Materialverhalten des heterogenen Betons gibt es gerade bei dessen Ermüdungsverhalten momentan noch viele nicht oder nicht ausreichend geklärte Fragestellungen. Deshalb befasst sich der vorliegende Beitrag mit der experimentellen Untersuchung des Ermüdungsverhaltens von Beton, speziell unter hochzyklischen Druckschwellbelastungen. Im Fokus der Untersuchungen stehen dabei die während der gesamten Lebensdauer im Materialgefüge ablaufenden Prozesse, die zu Veränderungen im Materialverhalten und schließlich auch bis zum Ermüdungsversagen führen können. Ziel ist es, eine möglichst realitätsnahe Beschreibung des im Materialgefüge ablaufenden Ermüdungsprozesses zu entwickeln.
Unter zyklischen Belastungen findet im Beton, wie bei anderen Materialien auch, ein Ermüdungsprozess statt, der letztlich im Versagen des Materials enden kann. Im derzeitigen Erkenntnisstand zum Materialverhalten des Betons gibt es gerade bei dessen Ermüdungsverhalten noch viele nicht oder nicht ausreichend geklärte Fragestellungen. Deshalb wurde in Laborversuchen das Ermüdungsverhalten von Beton unter Druckschwellbeanspruchungen untersucht. Im Fokus dieser Untersuchungen standen dabei die während der Lebensdauer im Materialgefüge ablaufenden Prozesse, die zur Schädigung des Gefüges und schließlich auch zum Ermüdungsversagen führen können.
In den Ermüdungsversuchen wurden versuchsbegleitend Dehnungsmessungen, Ultraschall-Laufzeitmessungen und Schallemissionsmessungen an den Proben zur Erfassung der Schädigungsevolution eingesetzt. Die Schallemissionsmessung ist dabei ein wichtiges Instrument, da sie die Rissentwicklungsprozesse detektiert, die die Ursache für die Materialschädigung sind. Mit ihr konnten die unterschiedlichen Phasen der Rissentwicklungen über die gesamte Lebensdauer der Betonproben festgestellt werden. Diese Phasen sind gekennzeichnet durch sich stabilisierende, stabile und instabile Rissprozesse, die entsprechende Auswirkungen auf das Materialverhalten haben. Ein Vergleich mit den Ergebnissen der anderen Messtechniken zeigt den entsprechenden Einfluss der Rissentwicklungen auf die Materialeigenschaften des Betons.