Packages for the transport of radioactive material are generally equipped with specific
structures (basket) to support the radioactive content in defined position. The safety function
of the basket depends on the kind of transported inventory. In case of transport cask for spent
fuel, the basket design has to ensure the subcriticality of the fissile material in all conditions
of transport in particular. Therefore the evaluation of structural integrity and neutron
absorption capability of the basket is an important part of complete safety analysis. Sufficient
heat transfer to maintain fuel assembly and cask temperature within allowable limits has to be
verified as well. Corrosion resistance is an additional requirement on basket materials owing
to contact with water during loading and unloading operations.
Computational and experimental methods or their combination along with additional material
and component tests can be used to analyse the mechanical and thermal basket behaviour
under transport conditions defined in IAEA regulations. By deciding between the analysis
methods, the design features (including material selection concept) as well as specific safety
function should be accounted.
In approval procedures of transport packages for radioactive materials, the competent
authority mechanical and thermal safety assessment is carried out in Germany by BAM. Some
questions of safety evaluation of basket designs are discussed in this paper based on the BAM
experience within approval procedures. The paper focuses primarily on the mechanical
behaviour of baskets with regard to the assumptions that have to be used in the criticality
safety demonstration. The state of the art methodologies for computational basket stress and
deformation analysis as well as for interpretation of drop tests results are presented.
In the approval procedure of transport packages for radioactive materials, the mechanical and thermal safety assessment is carried out in Germany by competent authority BAM. In recent years BAM was involved in several licensing procedures of new spent fuel and HLW package designs, where the cask body was made of Ductile Cast Iron (DCI). According to IAEA regulations package designs have to fulfill requirements for specific conditions of transport. Type B(U) packages must withstand the defined accident conditions of transport. The temperature range from -40°C up to the operational temperature has to be considered. For the cask material DCI, it is necessary to determine the brittle fracture behavior. The German guideline BAM-GGR 007 defines requirements for the fracture mechanics of DCI. Due to complex structure of the cask body and the dynamic loading a fracture mechanical assessment in an analytical kind is not always possible. Experience of recent design approval procedures show that the application of numerical calculations are applicable to determine the fracture mechanical load in the cask body. At the first step a numerical analysis has to be done to identify the loading state at the whole cask body. Secondly an analysis of a detail of the cask body is made considering the displacement boundary conditions of the global model. An artificial flaw is considered in this detailed model to calculate the fracture mechanical loading state. The finite element mesh was strongly refined in the area of flaw. The size of the artificial flaw is characterized by the ultrasonic inspection used for the quality assurance of the package. The applicant developed additional analysis tools for calculation of stress intensity factor and/or J-Integral. The assessment approach by BAM led to the decision to develop own tools to the possibility for independent check of the results.
The paper describes the authority assessment approach for the DCI fracture mechanics analysis. The validation procedure incl. the development of own tools is explained. BAM developed a post-processor called JINFEM to determine the fracture mechanical loads. The regulatory 1 m puncture bar drop test is used to give an example of the assessment procedure.
Transport of large nuclear power plant components: experiences in mechanical design assessment
(2009)
In the course of decommissioning of power plants in Germany large nuclear components (steam generator, reactor pressure vessel) must be transported over public traffic routes to interim storage facilities, where they are dismantled or stored temporarily. Since it concerns surface contaminated objects or low specific activity materials, a safety evaluation considering the IAEA transport regulations mainly for industrial packages (type IP-2) is necessary. For these types of industrial packages the requirements from normal transport conditions are to be covered for the mechanical proof. For example, a free drop of the package from a defined height, in dependence of its mass, onto an unyielding target, and a stacking test are required. Since physical drop tests are impossible generally due to the singularity of such 'packages', a calculation has to be performed, preferably by a complex numerical analysis. The assessment of the loads takes place on the basis of local stress distributions, also with consideration of radiation induced brittleness of the material and with consideration of recent scientific investigation results. Large nuclear components have typically been transported in an unpackaged manner, so that the external shell of the component provides the packaging wall. The investigation must consider the entire component including all penetration areas such as manholes or nozzles. According to the present IAEA regulations the drop position is to be examined, which causes the maximum damage to the package. In the case of a transport under special arrangement a drop only in an attitude representing the usual handling position (administratively controlled) is necessary. If dose rate values of the package are higher than maximum allowable values for a public transport, then it is necessary that additional shielding construction units are attached to the large component.