Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (33)
- Vortrag (26)
- Beitrag zu einem Tagungsband (20)
- Forschungsbericht (13)
- Beitrag zu einem Sammelband (11)
- Posterpräsentation (5)
- Sonstiges (3)
Schlagworte
- Aerosol (10)
- Laserdrucker (8)
- Cascade impactor (7)
- TXRF (7)
- Blauer Engel (6)
- Particles (6)
- Bürogeräte (5)
- Air quality monitoring (4)
- Emissionen (4)
- ICP-MS (4)
Organisationseinheit der BAM
- 4 Material und Umwelt (27)
- 4.2 Material-Mikrobiom Wechselwirkungen (24)
- 1 Analytische Chemie; Referenzmaterialien (2)
- 1.4 Prozessanalytik (2)
- 4.5 Kunst- und Kulturgutanalyse (2)
- 8 Zerstörungsfreie Prüfung (2)
- 8.3 Thermografische Verfahren (2)
- 9 Komponentensicherheit (2)
- 9.3 Schweißtechnische Fertigungsverfahren (2)
- 4.0 Abteilungsleitung und andere (1)
Paper des Monats
- ja (1)
Eingeladener Vortrag
- nein (26)
Development of wood-inorganic composites with enhanced properties and environmental stability
(2002)
Ultrafine particles emitted from laser printers are suspected to elicit adverse health effects. We performed 75-minute exposures to emissions of laser printing devices (LPDs) in a standardized, randomized, cross- over manner in 23 healthy subjects, 14 mild, stable asthmatics, and 15 persons reporting symptoms associated with LPD emissions. Low-level exposures (LLE) ranged at the particle background (3000 cm−3) and High-level exposures (HLE) at 100 000 cm−3. Examinations before and after exp sures included spirometry, body plethysmography, transfer factors for CO and NO (TLCO, TLNO), bronchial and alveolar NO, cytokines in serum and nasal secretions (IL-1β, IL-5, IL-6, IL-8, GM-CSF, IFNγ, TNFα), serum ECP, and IgE. Across all participants, no statistically significant changes occurred for lung mechanics and NO. There was a decrease in volume-related TLNO that was more pronounced in HLE, but the difference to LLE was not significant. ECP and IgE increased in the same way after exposures. Nasal IL-6 showed a higher increase after LLE. There was no coherent pattern regarding the responses in the participant subgroups or single sets of variables. In conclusion, the experimental acute responses to short but very high-level LPD exposures were small and did not indicate clinically relevant effects compared to low particle number concentrations.
In einem von der Firma GSE Lining Technology GmbH geförderten F+E-Vorhaben wurde die Langzeitscherfestigkeit und die Oxidationsstabilität von deren strukturierten PE-HD- Dichtungsbahnen untersucht. Bei diesen strukturierten Dichtungsbahnen wird das Strukturmaterial in einem eigenen Arbeitsgang aufgebracht. Das PE-HD-Material der Grundbahn war in allen Fällen Vestolen A 3512 R. Für das Strukturmaterial wurden die PE- LLD-Werkstoffe Ladene 118 N mit zwei Rußbatches (Proben 229/1 und 229/2) und Dowlex 2045 E mit zwei Rußbatches (Proben 229/3 und 229/4) verwendet. Die Langzeitscherfestigkeit wurde in Zeitstand-Scherversuchen in Wasser bei 80 °C getestet und dabei auch die Veränderung der OIT Werte von Grundbahn und Strukturmaterial gemessen. Die Oxidationsstabilität des Strukturmaterials im Vergleich zur Grundbahn wurde in Autoklavenversuchen an Proben im Wasserbad unter einem Sauerstoffdruck von 20 bar und 80°C geprüft. Nach der Immersion wurde die Veränderung der Reibungsparameter in Scherkastenversuchen ermittelt.
Dr. Stefan Seeger of the German Federal Institute for Materials Research and Testing (Bundesanstalt für Materialforschung und -prüfung - BAM) tells of his successful experience using Granta's CES software to make an eco-materials knowledge resource for automotive, construction, and other industries in the Berlin region.
Geomembranes used in basal liner systems of landfills must not be damaged by the coarse gravel of the standard drainage layer. Therefore, the geomembrane must be protected against mechanical damage and strain by means of a suitable protective layer. The main requirements for this protective layer as well as the long-term durability of the mineral and geotextile components are compiled in the guideline recently released by German authorities. An overview is given on the existing types of protective layer systems with the state-of-the-art testing, the requirements and selected results of related research programs.
Zulassung von Schutzlagen
(1995)
Long term waste containment - A challenge to geotextiles and geomembranes made of plastic materials
(1997)
Qualitative characterization of nanoparticle emissions from office machines with printing functions
(2007)
Quantitative and Qualitative Comparison of Particulate Emissions from Office Machines (ABSTRACT)
(2009)
Heterogene Explosionen
(2002)
Geosynthetic clay liners (GCLs) often have a sandwich-like multilayer structure, e.g. bentonite encased between two geotextile layers connected by fibers or yarns, either by needle-punching or stitch-bonding. Therefore, the internal shear strength of the GCL depends on the strength of reinforcing fiber bundles or yarns and their anchoring strength in the cover and carrier geotextiles. When used on long and steep slopes and covered with thick soil layers, the GCL is permanently exposed to a combined action of compressive and shear stress. Such load conditions are characteristic for landfill covers and the slope stability of the overall cover system in the long run strongly depends on the long-term internal shear strength of the GCL. A new test method was developed to study this long-term shear behavior. The focus was not only on creep, as it is normally done, but on aging effects. The shear test devices allow the measurement of creep curves and times-to-failure at elevated temperatures in different media (tap water and de-ionized water). In this publication, the main findings of the experiments on needle-punched GCLs with and without thermal treatment are summarized. Tap water as a test medium was essential to ensure sodium to calcium ion exchange in the bentonite layer. Under this condition extremely long test durations without failure were achieved. Sliding failure occurred when de-ionized water was used. Two failure modes were observed: brittle failure of the GCLs with thermal treatment and slow disentanglement of fiber bundles for untreated GCLs. Short-term shear strength (e.g. peel strength) is unrelated to the actual long-term shear strength, i.e. to the times-to-failure achieved in long-term shear strength test. Hence, short-term shear strength alone will not provide reliable dimensioning data for product design and choice of resins. Therefore, the often suggested approach, namely, restriction to short-term tests only and application of factors of safety, is challenged by these results.
Beim Abbrand einzelner Feuerwerkskörper für den Indoor-Bereich wurden als gasförmige Hauptreaktionsprodukte unter anderem CO2, CO, COS, nitrose Gase, diverse Kohlenwasserstoffe und Schwefelverbindungen (teilweise in sehr hohen Konzentrationen) mit Hilfe der FTIR-Spektroskopie nachgewiesen. Zusätzliche Feinstaubmessungen parallel zum Abbrand in einem großen Raum illustrierten die zeitweise hohen Partikelkonzentrationen an unterschiedlichen Messpunkten.
This work presents results of investigations towards the emission of chemical reaction products and sound pressure during an outdoor and an indoor firework display. Potentially harmful and toxic gases, and aerosols, were measured as well as sound pressures. Aerosols were measured with a Differential Mobility Analyzer (DMA) as well as a Laser Particle Counter. The focus was on particles with diameters between 11 nm and 20 µm. A transportable Fourier Transform Infrared (FTIR) spectroscopy detector registered the concentrations of emitted reaction gases, simultaneously. During the outdoor firework display, peak particle concentrations of >550000 particles cm-3, equivalent to a mass concentration of approximately 3.95 mg m-3, were detected, revealing a concentration maximum at approximately 175 nm particle diameter. The time-averaged particle mass concentration did not exceed 1.58 mg m-3 over 15 minutes. Due to the large distances (110 m) to the firing points, no significant harmful or toxic gas concentrations were measured during the entire firework display. In contrast, concentrations of sulphur dioxide (SO2) rose after an indoor firework display in a large event hall. On two days, more than 23000 particles cm-3 (which equates to a mass concentration of approximately 0.41 mg m-3) were detected when the hall ventilation was turned off, and more than 11000 particles cm-3 (which equates to a mass concentration of approximately 1.18 mg m-3) when the hall ventilation was activated. Concentration maxima appeared at approximately 300 nm particle diameter. The time-averaged particle concentrations in this case did not exceed 0.56 mg m-3 (over 15 minutes).