Filtern
Erscheinungsjahr
Dokumenttyp
- Vortrag (31)
- Beitrag zu einem Tagungsband (28)
- Zeitschriftenartikel (25)
- Posterpräsentation (9)
- Forschungsdatensatz (5)
- Buchkapitel (3)
- Sonstiges (3)
- Forschungsbericht (2)
- Monografie (1)
- Beitrag zu einem Sammelband (1)
Schlagworte
- Zerstörungsfreie Prüfung (22)
- Non-destructive testing (17)
- Validation (13)
- Brücken (11)
- NDT (11)
- Nondestructive testing (10)
- Air-coupled ultrasound (9)
- Ultrasound (9)
- Beton (8)
- Bridge (8)
Organisationseinheit der BAM
- 8 Zerstörungsfreie Prüfung (74)
- 8.2 Zerstörungsfreie Prüfmethoden für das Bauwesen (74)
- 7 Bauwerkssicherheit (4)
- 7.1 Baustoffe (2)
- 7.6 Korrosion und Korrosionsschutz (2)
- 3 Gefahrgutumschließungen; Energiespeicher (1)
- 3.5 Sicherheit von Gasspeichern (1)
- 6 Materialchemie (1)
- 6.3 Strukturanalytik (1)
- 8.4 Akustische und elektromagnetische Verfahren (1)
Eingeladener Vortrag
- nein (31)
ZfPStatik bezeichnet die Verwendung von statistisch bewerteten Messergebnissen, die mit zerstörungsfreien Prüfverfahren im Bauwesen (ZfPBau) gewonnen werden und in statischen Berechnungen zum Nachweis der Tragfähigkeit verwendet werden. Dazu ist die Ermittlung der Messunsicherheit der Versuchsdaten auf der Basis des GUM (Guide to the Expression of Uncertainty in Measurement) der erste Schritt. Der statische Nachweis erfolgt durch Grenzzustandsgleichungen, die im Bauwesen angewandt werden. Diese müssen modifiziert werden, so dass jede Messgröße als Zufallsvariable in der Grenzzustandsgleichung vorhanden ist. Der statische Nachweis erfolgt mit probabilistischen Berechnungsmethoden aus der Zuverlässigkeitstheorie. Diese Vorgehensweise wird exemplarisch für den Standsicherheitsnachweis eines Plattenbalkenquerschnitts einer Stahlbetonbrücke auf Biegung angewandt. Auf die möglichen Schlussfolgerungen aus den probabilistischen Berechnungen wird abschließend kurz eingegangen.
Die zerstörungsfreien Prüfverfahren konnten ihre Fähigkeit bei der Untersuchung von Elementwänden in einzelnen Fallstudien erbringen. Aufbauend auf den Kenntnissen aus der Praxis und auf Testreihen im Rahmen von Laboruntersuchungen wurde ein erster Ringversuch geplant und durchgeführt. Im Rahmen dieses Ringversuchs wurden verschiedene Strukturdefekte und Einbauteile in Elementwände eingebaut. Die Messung der Wände erfolgte anschließend durch mehrere Messteams mit unterschiedlichen zerstörungsfreien Prüfverfahren. Zum Einsatz kamen hierbei das Ultraschall-Echo- und das Impact-Echo-Verfahren sowie das Impuls-Radar-Verfahren. Zur Verbesserung der Vergleichbarkeit zwischen den unterschiedlichen Prüfverfahren wurde auf die Elementwände ein einheitliches Messraster aufgebracht. Für eine möglichst objektive Messung der Wände erhielten die Messteams vor den Messungen keine Details zu den Strukturdefekten oder Einbauteilen. Die Prüfaufgabe bestand darin, die Wände mit dem jeweiligen Prüfverfahren zu untersuchen. Anschließend wurden die Ergebnisse der Messteams zentral gesammelt und ausgewertet. Anhand der zentralen Auswertung sollten Aussagen zu den eingebauten Inhomogenitäten ableitet werden. Hierdurch kann zum einen die Leistungsfähigkeit der Prüfverfahren an unterschiedlichsten Inhomogenitäten getestet werden, zum anderen können die Ergebnisse und somit die Prüfverfahren untereinander verglichen werden. Zu diesen in der Praxis immer häufiger vorkommenden Fragestellungen können grundsätzliche Aussagen zum Einsatz von zerstörungsfreien Prüfungen bei Elementwänden gewonnen werden. Über die Ergebnisse dieses Ringversuches wird nachfolgend berichtet.
Messen heißt wissen. Dieses Wissen spiegelt die Realität wider und soll den Statiker eines bestehenden Bauwerkes bei der Entscheidungsfindung über die Sicherheit und Zuverlässigkeit der Konstruktion unterstützen. Gegenüber dem Neubauentwurf können bei der Bewertung von bestehender Bausubstanz Sicherheitsreserven genutzt werden, da Unsicherheiten, die beim Bau auftreten können, besser bekannt oder nicht mehr vorhanden sind. Können solche Unsicherheiten genauer bewertet werden, z. B. durch die Feststellung der genauen Lage der Spannglieder bei einer Spannbetonbrücke, so können Sicherheitsbeiwerte reduziert werden, ohne dass es dabei zu Auswirkungen auf das normativ festgelegte Zuverlässigkeitsniveau kommt. Mittlerweile sind Prüfmethoden an Bauwerken wirtschaftlich einsetzbar und auch so leistungsfähig, dass die für die Tragfähigkeit und Gebrauchstauglichkeit wesentlichen Parameter identifiziert werden können. Ein wesentlicher Punkt ist hierbei die Integration derartiger Messergebnisse in Rechenmodelle, die für die Nachrechnung des Bauwerks verwendet werden. Dies können sowohl semiprobabilistische Rechenmodelle als auch vollprobabilistische Modelle sein. Bei semiprobabilistischen Methoden können aus den Messergebnissen Teilsicherheitsbeiwerte berechnet und abgeleitet werden, die dann in den bekannten Nachweisformaten gemäß den Eurocodes und der Nachrechnungsrichtlinie berücksichtigt werden. Bei vollprobabilistischen Nachweisen können die Messdaten in Form von Verteilungsdichtefunktionen mit gemessenen Variationskoeffizienten direkt in das Rechenmodell eingehen.
This contribution attempts to shed light on the application of POD analyses and measurement uncertainty calculations in nondestructive testing of concrete structures to provide useful and quality-assured information for reliability assessments of our built environment - with an emphasis on ground penetrating radar. It is shown that signal processing techniques affect POD analysis results to varying degrees, that measurement uncertainties are useful to validate PODs, and that the utilization of both POD analysis and measurement uncertainty calculations can pave the way to NDT-based reliability assessment, which will be exemplarily demonstrated in conclusion – generally aiming to derive those maintenance strategies and actions that are in line with actual demands.
Zerstörungsfreie Prüfverfahren (ZfPBau-Verfahren) sind auch im Bauwesen stets an praxisrelevante Prüfaufgaben gekoppelt. Die Ermittlung beispielsweise eines Ist-Zustandes im Vorfeld einer Betoninstandsetzung oder die Ermittlung von Schadensursache und Schadensumfang als Folge wiederkehrender Untersuchungen von Brücken nach DIN 1076 sind etablierte Anwendungsgebiete der ZfPBau. Mit der Einführung der Nachrechnungsrichtlinie für Straßenbrücken im Jahr 2011 hat die Nachfrage nach ZfPBau-Dienstleistungen einerseits stark zugenommen, andererseits eröffnet sie Möglichkeiten, in statischen Nachweisen die tatsächlichen Eigenschaften bestehender Konstruktionen rechnerisch anzusetzen. Dazu aber müssen Messergebnisse statistisch bewertet werden können. Dies geschieht durch eine einheitliche Ermittlung der Messunsicherheit, mit der die Voraussetzungen geschaffen werden, um Messergebnisse von ZfPBau-Verfahren in statischen Berechnungen verwenden zu können. Im folgenden Beitrag wird gezeigt, wie Messgrößen der ZfPBau als (stochastische) Basisvariablen in probabilistische Nachweise zur Berechnung der Zuverlässigkeit einfließen können, indem Grenzzustandsgleichungen modifiziert werden. Mit dieser Vorgehensweise sind weitere Schlussfolgerungen aus den Ergebnissen möglich.
Validation of artificial defects for non-destructive testing measurements on a reference structure
(2018)
Non-destructive testing was established over the last decades as an important tool for assessing damages, material characterization and quality assurance in civil engineering. For example, Ground Penetrating Radar (GPR) can be used to scan large areas of concrete structures to determine the spatial position of the reinforcement. With the ultrasonic echo method, the thickness of concrete structures can be easily determined even if a high density of reinforcement is given. Various methods and processes have been developed for the validation of NDT procedures aiming at ensuring the quality of measurements in practical use. The Probability of Detection (POD) for example, is an available method to compare different technical devices with each other quantitatively regarding their performance. With this method, the best suited testing device for a specific inspection task under defined boundary conditions can be selected. By using the Guide to the Expression of Uncertainty in Measurement (GUM), it is possible to quantify the measurement uncertainty of an inspection procedure for a specific task. Another important aspect to improve the acceptance of Non-destructive testing methods is the development of reference specimens.
Reference specimens serve for the calibration and further development of NDT methods under realistic conditions in different laboratories under the same conditions. A particular challenge here is the most realistic representation of a damage that can occur at building sites. Possible damages include for example horizontal and vertical cracks or honeycombs in concrete. Such a reference structure was built for the development of a new design of power plant constructions. Comparative studies on the manufacturing of realistic honeycombs and delaminations were carried out in advance on a test specimen. The results of this study are presented here.
Validation of artificial defects for Non-destructive testing measurements on a reference structure
(2018)
Non-destructive testing was established over the last decades as an important tool for assessing damages, material characterization and quality assurance in civil engineering. For example, Ground Penetrating Radar (GPR) can be used to scan large areas of concrete structures to determine the spatial position of the reinforcement. With the ultrasonic echo method, the thickness of concrete structures can be easily determined even if a high density of reinforcement is given. Various methods and processes have been developed for the validation of NDT procedures aiming at ensuring the quality of measurements in practical use. The Probability of Detection (POD) for example, is an available method to compare different technical devices with each other quantitatively regarding their performance. With this method, the best suited testing device for a specific inspection task under defined boundary conditions can be selected. By using the Guide to the Expression of Uncertainty in Measurement (GUM), it is possible to quantify the measurement uncertainty of an inspection procedure for a specific task. Another important aspect to improve the acceptance of non-destructive testing methods is the development of reference specimens.
Reference specimens serve for the calibration and further development of NDT methods under realistic conditions in different laboratories under the same conditions. This is an essential prerequisite for round robin tests. A particular challenge here is the most realistic representation of a damage that can occur at building sites. Possible damages include for example horizontal and vertical cracks or honeycombs in concrete. Such a reference structure was built for the development of a new design of power plant constructions. Comparative studies on the manufacturing of realistic honeycombs and delaminations were carried out in advance on a test specimen. The results of this study are presented here.
Ultrasonic testing is a widely applied measurement method in materials research and medicine. Commonly, a transducer is coupled to the specimen directly or via a liquid coupling agent. While reducing acoustic transmission losses significantly, this procedure is time-consuming and cannot be used for sensitive specimens. Air-coupled ultrasound is a viable alternative in such cases, although suffering from very high acoustic transmission losses between transducer, air and specimen. The recently introduced fluidic transducer (FT) generates ultrasound by utilizing the instability of a supersonic air jet switched inside a fluidic amplifier. Since only air is used as the working medium and no vibrating surfaces are used for ultrasound generation, the transducer is able to efficiently generate large acoustic pressure amplitudes. The resulting acoustic field shares its directivity with the ejected high-velocity air jet. Thus, the acoustic energy needs to be redirected from the jet axis in order to make the fluidic transducer applicable to sensitive specimens. In this study, the effectivity of using sonic crystals (SCs) for this redirection is investigated using acoustic and flow measurements. SCs are air-permeable while being reflective to large acoustic frequency bands. It was shown that both a defect waveguide and a mirroring strategy successfully redirected the acoustic field from the air jet. Furthermore, the interaction of flow and SC showed strong acoustic quenching if the SC was placed too close to the FT outlet. Blockage of the jet entrainment due to the SC may result in slightly higher off-axis flow velocities locally, which should be considered in sensitive applications.
Untersuchungen zum Schallfeld niederfrequenter Ultraschallprüfköpfe für die Anwendung im Bauwesen
(2012)
Durch intensive praxisbezogene Forschung konnte in den letzten Jahrzehnten das Spektrum der zerstörungsfreien Prüfverfahren im Bauwesen deutlich erweitert werden. Die akustischen Methoden im Bereich des Niederfrequenz-Ultraschalls nehmen hierbei eine zentrale Rolle ein. Mit der Einführung von kontaktmittelfrei arbeitenden Prüfköpfen gelang es schließlich, eine breite Akzeptanz für diese Untersuchungsmethode in der Praxis zu erzielen. Bedingt durch die oft großen Untersuchungsflächen, rückte die Dauer der Messdatenaufnahme unter wirtschaftlichen Gesichtspunkten immer mehr in den Fokus der Forschung. Eine Optimierung der Messzeit durch den Einsatz von vollautomatischen Scannern oder von parallel arbeitenden Prüfköpfen ist nur einem begrenzten Umfang möglich. In der Grundlagenarbeit „Luftgekoppeltes Ultraschallecho-Verfahren für Betonbauteile“ zeigt Herr Dr.- Ing. B. Gräfe das Potenzial der berührungslos arbeitenden Schallanregung hinsichtlich der Verringerung der Messzeit auf. Das Ziel der vorliegenden Arbeit ist es, grundlegende Fragestellungen für eine baupraktische Anwendung des luftgekoppelten Ultraschallecho-Verfahrens zu beantworten. Die sich ausbildenden Wellenarten hängen maßgeblich vom Winkel, unter dem der Schallimpuls aus der Luft auf die Oberfläche auftrifft und dem Abstand des Prüfkopfes zum Bauteil ab. Ein zentraler Punkt ist daher die genaue Kenntnis der Eigenschaften der angeregten Schallfelder unter Berücksichtigung dieser Randbedingungen. Mit der physikalischen Beschreibung des Schallfeldes ist es möglich, das Messverfahren hinsichtlich der verschieden gestellten Prüfaufgaben zu optimieren und Auswertungs- algorithmen zur sicheren Interpretation der Messdaten zu entwickeln. Recherchen zum Thema der Schallfeldanalysen in Festkörpern im Niederfrequenz-Bereich ergaben, dass auch die Kenntnisse zu den bereits weitverbreiteten Kontaktprüfköpfen nicht in einem ausreichenden Umfang messtechnisch abgesichert waren. Daher wurden diese ebenfalls in das Messprogramm aufgenommen. Für die Bestimmung der Kennwerte des Schallfeldes von Ultraschallprüfköpfen wurde ein Prüfstand geplant und gebaut. Das Konzept des Prüfstandes ist so ausgerichtet, dass neben der räumlichen Erfassung des Schallfeldes zusätzlich die stofflichen Einflüsse des durchschallten Mediums erfasst werden. Dies wird durch die Messung an halbkugelförmigen Probekörpern mit unterschiedlichen Durchmessern erreicht. Der Schwerpunkt der Untersuchungen liegt auf dem Werkstoff Beton. Bei dem Probenmaterial handelt es sich um einen selbstverdichtenden Beton, dessen Zusammensetzung geringe schallschwächende Eigenschaften aufweist. Die Rezepturen für diese Betone wurden an der Technischen Universität Berlin entwickelt. Es wurden Serien von jeweils vier Probekörpern unterschiedlicher Materialeigenschaften hergestellt. Variiert wurde bei den Serien der Probekörper die Größe der Gesteinskörnung, um eine erste Einschätzung des Einflusses der Materialzusammen- setzung auf das Schallfeld vornehmen zu können. Die Messdaten werden mit einer eigenständig entwickelten Software aufgezeichnet und ausgewertet. Aus den experimentell gewonnenen Kennwerten werden anschließend erstmalig räumliche Schallfelder für den Niederfrequenz-Bereich im Beton berechnet. Die Verifikation der Messergebnisse erfolgte durch den Einsatz unterschiedlicher Simulationsverfahren, die durch Partnerinstitute durchgeführt wurden. Im baupraktischen Teil der Arbeit werden die Erfahrungen aus realen Schadensanalysen präsentiert. Hierauf aufbauend wurden im Rahmen einer parallel laufenden Forschungsarbeit Probekörper hergestellt, an denen erste Untersuchungen mit einer luftgekoppelten Schallanregung durchgeführt wurden. Zu diesem Zweck wurden neben den Schallfeldanalysen Parameterstudien zu den optimalen Bedingungen der Schallanregung notwendig. Insbesondere die Oberflächenwellen und deren störender Einfluss wurden hierbei systematisch untersucht. Neben der Präsentation erfolgreicher Ergebnisse werden auch die gegenwärtigen Grenzen des Verfahrens aufgezeigt.
Im deutschen Eisenbahnnetz sind ca. 80 Millionen Spannbetonschwellen verbaut. Analog zu anderen Bauwerken werden Wpannbetonschwellen regelmäßig visuell inspiziert. Die Rissbildung ist bei diesen Inspektionen ein Kriterium für die Schädigung einer Spannbetonschwelle. Durch Rissbildung kann es passieren, dass Betonschwellen ihre Nutzungsdauer nicht erreichen.