This project addresses the application of safe and healthy workplaces in offices, chemical laboratories and other workplaces where indoor air quality plays an important role. The LoRaWAN (Long Range Wide Area Network) is used as a communication interface to make sensor data globally accessible.
The objectives of the project are to create a sensor node and an online and offline system that collects the data from the sensor nodes and stores it on a local server, in a cloud, and also locally on the node to prevent communication failures. An important point in this project is the development of the sensor nodes and the placement of these in the premises, thus no development work is involved in Building the infrastructure.
One of the more difficult tasks for structural health monitoring is the continuous evaluation of the stability and load capacity of the building materials. This knowledge can be won, e.g., by taking material samples at the examining place with the drawback of partly destroying the structure. To avoid this, modern sensor and communication technologies offer promising methods for non-destructive testing. To address the tasks for monitoring of concrete structures, in the presented study, different sensors were combined with RFID transponders and embedded in concrete components.
This paper deals with the development and investi-gation of a volatile organic compound (VOC) system for differ-ent scenarios. The integrated multi-sensor unit can detect dif-ferent gases through the integrated 3-fold VOC sensor, where-by a continuous measurement takes place. The system-integrated flow control, with pump and flow sensor, allows the gas molecules to be transported directly to the VOC sensor. The entire measurement is permanently stored on an integrat-ed Secure Digital (SD) card. If the previously determined limit range is exceeded, an alarm is generated. Due to the combina-tion of different components, numerous applications are possi-ble. The system is the first step or a tool towards further devel-opments in the field of gas sensors and is primarily used for the validation of chemically based gas sensors, and it is still largely extended by application-specific influences.
For dangerous goods packagings, drop testing onto an essential unyielding target can be used to assess the mechanical resistance to impact loads. Adopted regulations like ADR/RID require that the impact surface provided shall be integral with a mass at least 50 times than that of the heaviest package to be tested. The problem is that many manufacturers do not possess impact targets that satisfy the required 50 times mass ratio for regulative drop tests during series production. The objective of this work is to verify existing and define improved criteria for impact target structures based on systematic investigations. Previous evidence highlights the relevance of other parameters in addition to the mass ratio. Therefore, in this research, a variation of drop test parameters was carried out experimentally. Furthermore, numerical vibration analysis was applied to investigate the deformability of the impact surface. The results conclude that the mass ratio of 1:50 cannot be defined as a decisive criterion. In order to determine the influence of further drop test parameters, the research findings were used to validate a parametric model which assesses impact target deflection. An approximation quality of over 90 % was achieved. As a result, new evaluation criteria are proposed. Firstly, a method for identifying critical impact target designs is provided. Secondly, a new comprehensive formula compares the approximated maximum deflection of a real impact target to the respective theoretical threshold derived from a worst-case assumption. In practice, this leads to great advantages in the evaluation of already installed impact targets for dangerous goods packagings.