Filtern
Dokumenttyp
- Beitrag zu einem Tagungsband (28)
- Posterpräsentation (20)
- Zeitschriftenartikel (14)
- Vortrag (8)
Sprache
- Englisch (61)
- Deutsch (8)
- Mehrsprachig (1)
Schlagworte
- Structural health monitoring (18)
- RFID sensors (13)
- Smart structures (12)
- Embedded sensors (10)
- Passive RFID (9)
- Sensors in concrete (9)
- Smart sensors (9)
- Drop test (7)
- RFID-based sensors (7)
- VOC (7)
Organisationseinheit der BAM
- 8 Zerstörungsfreie Prüfung (35)
- 8.1 Sensorik, mess- und prüftechnische Verfahren (34)
- 8.2 Zerstörungsfreie Prüfmethoden für das Bauwesen (14)
- 3 Gefahrgutumschließungen; Energiespeicher (6)
- 3.1 Sicherheit von Gefahrgutverpackungen und Batterien (6)
- 1 Analytische Chemie; Referenzmaterialien (4)
- 1.9 Chemische und optische Sensorik (4)
- 7 Bauwerkssicherheit (4)
- 7.4 Baustofftechnologie (4)
- 8.6 Faseroptische Sensorik (4)
Paper des Monats
- ja (3)
Eingeladener Vortrag (wissenschaftliche Konferenzen)
- nein (8)
The mechanical and geometrical properties of impact targets greatly influence the outcome of a drop test. The International Agreement concerning the International Carriage of Dangerous Goods by Road (ADR) as well as ISO 2248 describe the characteristics of impact targets for drop tests of dangerous goods packagings.
According to these regulations, the impact target’s surface needs to be unyielding, under testing conditions non-deformable, flat, and integral with a mass at least 50 times that of the heaviest packaging to be tested. The problem is that many production facilities, especially manufacturers of corrugated fibreboard boxes, do not have their own testing device with the required 50 times mass ratio of the impact target for a regulation compliant drop test during series production. Furthermore, at UN level it is considered necessary to revise these requirements.
In the present paper, the impact target requirements are examined in detail and compared with those in other technical areas (e.g., impact target for container for the transport of radioactive materials). A research method is being developed to investigate the dependency between the mass ratio of the packaging and the target as well as the damage resistance of a drop tested package in relation to specific design characteristics. The results are of high relevance for industry purposes and intended to ensure a uniform level of safety assessment for the mechanical testing of dangerous goods packagings.
For dangerous goods packagings, drop testing onto an essential unyielding target can be used to assess the mechanical resistance to impact loads. Adopted regulations like ADR/RID require that the impact surface provided shall be integral with a mass at least 50 times than that of the heaviest package to be tested. The problem is that many manufacturers do not possess impact targets that satisfy the required 50 times mass ratio for regulative drop tests during series production. The objective of this work is to verify existing and define improved criteria for impact target structures based on systematic investigations. Previous evidence highlights the relevance of other parameters in addition to the mass ratio. Therefore, in this research, a variation of drop test parameters was carried out experimentally. Furthermore, numerical vibration analysis was applied to investigate the deformability of the impact surface. The results conclude that the mass ratio of 1:50 cannot be defined as a decisive criterion. In order to determine the influence of further drop test parameters, the research findings were used to validate a parametric model which assesses impact target deflection. An approximation quality of over 90 % was achieved. As a result, new evaluation criteria are proposed. Firstly, a method for identifying critical impact target designs is provided. Secondly, a new comprehensive formula compares the approximated maximum deflection of a real impact target to the respective theoretical threshold derived from a worst-case assumption. In practice, this leads to great advantages in the evaluation of already installed impact targets for dangerous goods packagings.
For dangerous goods packagings, drop testing onto an essential unyielding target can be used to assess the mechanical resistance to impact loads. Adopted regulations like ADR/RID require that the impact surface provided shall be integral with a mass at least 50 times than that of the heaviest package to be tested. The problem is that many manufacturers do not possess impact targets that satisfy the required 50 times mass ratio for regulative drop tests during series production. The objective of this work is to verify existing and define improved criteria for impact target structures based on systematic investigations. Previous evidence highlights the relevance of other parameters in addition to the mass ratio. Therefore, in this research, a variation of drop test parameters was carried out experimentally. Furthermore, numerical vibration analysis was applied to investigate the deformability of the impact surface. The results conclude that the mass ratio of 1:50 cannot be defined as a decisive criterion. In order to determine the influence of further drop test parameters, the research findings were used to validate a parametric model which assesses impact target deflection. An approximation quality of over 90 % was achieved. As a result, new evaluation criteria are proposed. Firstly, a method for identifying critical impact target designs is provided. Secondly, a new comprehensive formula compares the approximated maximum deflection of a real impact target to the respective theoretical threshold derived from a worst-case assumption. In practice, this leads to great advantages in the evaluation of already installed impact targets for dangerous goods packagings.
Packagings for the transport of dangerous goods need to meet special requirements to get an approval. This includes free fall drop testing onto an essentially unyielding surface as a means to assess a package’s resistance to mechanical damage. A main requirement for drop tests is that the impact target’s mass shall be at least 50 times that of the heaviest package to be tested. Nevertheless, many manufacturers do not possess foundation structures with the required mass ratio. Previous evidence highlights that the mass ratio is not a decisive criterion on its own. Parameters such as the impact target foundation’s connection and the impulse experienced by the impacting object are essential as well. However, these factors are not easily verifiable since experimental measurements are not possible at most facilities. The objective of this work is to provide a detailed analysis on the interaction between impact target foundation and subgrade in dynamic impact testing using validated finite-element (FE) models. This research is highly beneficial for industrial application since it allows manufacturers to make informed predictions about the mechanical response of installed impact target foundations.
Due to the high damping mechanical properties of fiberboard materials, corrugated fiberboard boxes are widely used as transport packagings of dangerous goods. Since there is risk of vertical impact within the distribution system, drop tests are performed as design type tests to assess a package’s ability to withstand damage. In this context, however, little is known regarding the transient mechanical response of a filled fiberboard box. The reason is that the nature of the packaging material presents challenges in identifying the deformation mechanisms experimentally. The aim of this work is to provide a framework for predicting the damage resistance of complete, filled corrugated fiberboard boxes which are ready for transportation. Therein, drop test finite-element simulations are used and validated by experimental results. These numerical calculation models are a valuable tool for virtual product development and contribute to the optimization of the design cycle.
In the approval process of dangerous goods packagings, drop tests onto a flat, essentially unyielding surface are used to assess resistance against mechanical damage. International adopted regulations like ADR and RID define filling good dependent drop heights and filling degrees whilst the user needs to define the maximum gross mass to be tested and approved. Maximum packaging gross mass is defined conservatively and not reached in practice. To meet the defined gross mass in testing, using additives is permitted. However, in some cases, additives are not desirable due to packaging design or filling substance properties. This leads to deviations from the initial gross mass definition. Hence, a certain drop height adjustment is necessary to achieve the required impact loading. Laboratories frequently adjust drop height assuming a perfectly elastic collision that is inaccurate. Appropriate adjustment is not trivial due to energy conversion processes, for example, plastic deformation. In this work, a test stand
In den letzten Jahrzehnten hat sich das Bauwerksmonitoring (engl. „Structural Health Monitoring“, SHM) zu einer nützlichen Ergänzung routinemäßiger Inspektionen entwickelt. SHM ermöglicht die frühzeitige Erkennung von Schäden an Bauwerken und dadurch die frühe, und somit kostengünstige, Durchführung von Reparatur- und Wartungsarbeiten. Mit dem Aufkommen drahtloser Technologien und Fortschritten in der Informations- und Kommunikationstechnologie werden Bauwerke zunehmend mit drahtlosen Sensorknoten ausgestattet, um für SHM relevante Bauwerksdaten zu erfassen, zu analysieren und zu übertragen. Eine vielversprechende Methode für SHM ist die direkte Einbettung von Sensoren in den Beton. In diesem Beitrag wird ein Sensorsystem zur Einbettung in Beton vorgestellt, das in der Lage ist, die im Beton aufgenommenen Bauwerksdaten auszuwerten. Die Sensoren werden bei Bedarf von vierbeinigen Robotern mittels Radio Frequency Identification (RFID) ausgelesen und mit Energie versorgt, was einen automatisierten und effizienten Prozess ermöglicht. Der prototypische Prozess zur automatischen Erfassung von Bauwerksdaten mit eingebetteter Sensorik und vierbeinigen Robotern wird durch Tests in einer Büroumgebung validiert. Die Ergebnisse der Tests bestätigen die automatische und effiziente Erfassung von Bauwerksdaten, die eine frühzeitige Erkennung von Bauwerksschäden, auch von nicht sichtbaren Schäden, ermöglicht, und eine folgerichtige Weiterentwicklung des
modernen Bauwerksmonitorings repräsentiert.
Piezoresistive accelerometers use a strainsensing element, generally made of semiconductor material, e.g., silicon to convert the mechanical motion into an electrical signal. This element is usually designed in form of a cantilever beam loaded with a mass. Acceleration causes bending
of the beam, which produces a change of electrical resistance proportional to the applied acceleration.
Main advantages of piezoresistive accelerometers in comparison to other types, e.g., piezoelectric and capacitive, is their robust and highly dynamic behavior, which qualifies them for application in high impact shock applications. Mechanical damping is typically implemented with silicon oil in a way that the output signal is undistorted over a wide frequency range. These characteristics principally qualify them for the application in drop tests carried out at BAM, for which they are calibrated over the frequency range from 1 to 4 kHz. However, using silicon oil for damping, has the drawback of temperature dependent change of its viscosity, leading to temperature dependent deviation of the accelerometer’s sensitivity. This study presents experimental results of the temperature behavior of a piezoresistive accelerometer with a dynamic range up to ±5000 g.
This type of accelerometer is applied for drop tests which are partially performed at temperatures of -40 or +100 °C.
This paper deals with the development and investi-gation of a volatile organic compound (VOC) system for differ-ent scenarios. The integrated multi-sensor unit can detect dif-ferent gases through the integrated 3-fold VOC sensor, where-by a continuous measurement takes place. The system-integrated flow control, with pump and flow sensor, allows the gas molecules to be transported directly to the VOC sensor. The entire measurement is permanently stored on an integrat-ed Secure Digital (SD) card. If the previously determined limit range is exceeded, an alarm is generated. Due to the combina-tion of different components, numerous applications are possi-ble. The system is the first step or a tool towards further devel-opments in the field of gas sensors and is primarily used for the validation of chemically based gas sensors, and it is still largely extended by application-specific influences.
This paper deals with the development and investi-gation of a volatile organic compound (VOC) system for differ-ent scenarios. The integrated multi-sensor unit can detect dif-ferent gases through the integrated 3-fold VOC sensor, where-by a continuous measurement takes place. The system-integrated flow control, with pump and flow sensor, allows the gas molecules to be transported directly to the VOC sensor. The entire measurement is permanently stored on an integrat-ed Secure Digital (SD) card. If the previously determined limit range is exceeded, an alarm is generated. Due to the combina-tion of different components, numerous applications are possi-ble. The system is the first step or a tool towards further devel-opments in the field of gas sensors and is primarily used for the validation of chemically based gas sensors, and it is still largely extended by application-specific influences.