Wind turbines on offshore sites (OWECs) are subjected to combined loads from wind and waves. These dynamic loads, with a frequency content within the range of the natural frequencies of the structures, cause fatigue-effective stresses in the substructures of wind turbines. Therefore, the examination of natural frequencies is an important part within the design process of wind turbines. The quality of the numerical models for such calculations is of great importance, since the certification guidelines permit only small uncertainties in modal analysis results. The accuracy of the parameters of the numerical model can only be achieved through a comparison of simulation results with corresponding test results. Therefore, it is necessary to measure the dynamic behaviour of all components of the wind turbines simultaneously. This is true not only for the design verification, but also for monitoring the OWECs in operation. The potential of integrated systems for monitoring-based maintenance optimisation should thus be used.
This paper establishes the model basis regarding the ultimate limit state consisting of structural, loading, and probabilistic models of the support structure of offshore wind energy converters together with a sensitivity study. The model basis is part of a risk based assessment and monitoring framework and will be applied for establishing the 'as designed and constructed' reliability as prior information for the assessment and as a basis for designing a monitoring system. The model basis is derived considering the constitutive physical equations and the methodology of solving these which then in combination with the ultimate limit state requirements leads to the specific constitutive relations. As a result finite element models based on shell elements incorporating a structural and a loading model are introduced and described in detail. Applying these models the ultimate capacity of the support structure and the tripod structure are determined with a geometrically and materially nonlinear finite element analysis. The observed failure mechanisms are the basis for the definition of the ultimate limit state responses. A probabilistic model accounting for the uncertainties involved is derived on the basis of literature review and measurement data from a prototype Multibrid M5000 support structure. In combination with the developed structural and loading models, sensitivity analyses in regard to the responses are performed to enhance the understanding and to refine the developed models. To this end, as the developed models necessitate substantial numerical efforts for the probabilistic response analysis predetermined designs of numerical experiments are applied for the calculation of the sensitivities using the Spearman rank correlation coefficient. With this quantification of the sensitivity of the random variables on the responses including nonlinearity the refinement of the model is performed on a quantitative basis.
The fatigue deterioration modeling for welded steel structures subjected to high cycle fatigue is presented in the current document. The aim of this paper is to formulate approaches based on actual Research results for the phases fatigue crack initiation, fatigue propagation and fatigue failure. The physical characteristics of the approaches are discussed in combination with the associated uncertainties and the probabilistic modeling of this time variant reliability problem. The fatigue deterioration modeling documented here serve as a basis for a reliability-based approach to inspection planning.
A reliability-based approach to inspection planning for welded steel structures subjected to high cycle fatigue is presented in the current document. Inspections are an effective means to control the Progress of fatigue deterioration and the presented approach allows to determine the minimum required inspection effort so that the considered structure complies with the given risk acceptance criteria in terms of target reliability throughout its service life.
Fatigue and serviceability limit state model basis for assessment of offshore wind energy converters
(2012)
This paper develops the models for the structural performance of the loading and probabilistic characterization for the fatigue and the serviceability limit states for the support structure of offshore wind energy converters. These models and a sensitivity study are part of a risk based assessment and monitoring framework and will be applied for establishing the 'as designed and constructed' reliability as prior information for the assessment and the design of monitoring systems. The constitutive physical equations are introduced in combination with the fatigue and serviceability limit state requirements as the starting point for the development of the structural performance and loading models. With these models introduced in detail, several modeling aspects for both limit states are analyzed. This includes analyses of the influence on the hot spot stresses by applying a contact formulation for the pile guide brace connection and the application of a finite element formulation using solid elements. Further, the comparison of the natural frequencies of a discrete rotor model with a continuous rotor model is documented. To account for uncertainties associated with the structural and loading models, a probabilistic model is derived on the basis of literature review and measurement data from a prototype Multibrid M5000 support structure. The sensitivity study is based on the calculation of a nonlinear coefficient of correlation in conjunction with predetermined designs of experiments. This is conducted by a systematic analysis of the influence of the random variables on limit state responses and hence on the structural reliability. Integrating the analyses and sensitivity studies of the fatigue and serviceability limit state models developed in this paper as well as the ultimate limit state models in Thöns et al. ('Ultimate Limit State Model Basis for Assessment of Offshore Wind Energy Converters,' ASME J. Offshore Mech. Arct. Eng.), the model basis for the assessment is completed. The process of establishing and analyzing such a model basis contributes to a detailed understanding of the deterministic and probabilistic characteristics of the structure and provides valuable insights in regard to the significance of available data.
A prototype of wind turbines in 5 megawatt dass was built and tested at the first German offshore wind energy test fteld in the North Sea. In order to investigate dynamic behaviors under a complex state of loads, a continuous dynamic monitoring System was implemented by Federal Institute for Material Research and Testing (BAM). It recorded structural responses and environmental/operational variables from November 2007 to October 2009.
This paper presents significant resonance phenomenon due to the interaction in the tower-nacelle System under operational conditions. Modal parameters are automatically estimated by the poly reference Least Square Complex Frequency domain (p-LSCF) method. Campbell plot demonstrates that a three-blade passage frequency and its multiples f3n match with the natural frequencies of the wind turbine System in several modal Orders. The damping estimates decrease and the Vibration amplitude increase significantly. A control System is necessary to minimize the excessive vibrations.
Vibration-based structural health monitoring of a wind turbine system. Part I: Resonance phenomenon
(2015)
This paper is focused on a resonance phenomenon of a wind turbine system in 5 MW class, on the basis of dynamic signals acquired continuously from the tubular tower under normal operational conditions during two years.
Firstly, technique specifications of the wind turbine system are introduced and a finite element model is developed to characterize the structural dynamic properties. The following part describes the continuous dynamic monitoring system integrated with an automated operational modal analysis procedure using the poly-reference Least Squares Complex Frequency domain (p-LSCF) method. Subsequently, variations and mutual relationships of environmental/operational factors such as vibration amplitude, temperature, wind speed, rotation speed of blades, pitch angle and nacelle direction are also presented. Finally, significant resonance is observed due to the fundamental frequency of the tower matching with the harmonic frequency induced by the rotation of three blades. As the rotation speed of rotor approaches to 8 rpm, the vibration amplitude of the tower increases significantly and the corresponding damping value decreases. With the further rising wind velocity, the rotation speed of blades stops increasing and the input energy just contribute to accumulate the vibration amplitude of tower. Such observation indicates the Sommerfeld effect that aggravates the resonance phenomenon. A vibration control device is necessary to minimize the excessive structural responses.
A companion paper will further discuss the environmental/operational effects on dynamic properties of the wind turbine system under the operational conditions.