Structural Health Monitoring (SHM) systems are designed for assisting owners and operators with information and forecasts concerning the fitness for purpose of structures and building systems. The benefit associated with the implementation of SHM may in some cases be intuitively anticipated or proven by past experiences but in general there appears to be no rational or systematic approach for assessing the value of SHM systems a-priory to their implementation. The present paper addresses the assessment of the value of SHM with basis in structural risk assessments and the Bayesian pre-posterior decision analysis. The quantification of the value of SHM builds upon the quantification of the value of information (VoI) or rather the benefit of monitoring. The suggested approach involves a probabilistic representation of the loads and environmental conditions acting on structures as well as their responses and performances over their life-cycle. In addition, the quality of monitoring and the performance of possible remedial actions triggered by monitoring results are modeled probabilistically.The consequences accounted for, in principle include all consequences associated with the performance of the structure over its life-cycle as well as the costs associated with monitoring and possible remedial actions. The suggested approach is illustrated through two case studies concerning the monitoring of welded details in steel structures subjected to fatigue loading. The case studies address the effect of the uncertainty associated with the performance of SHM on the value of SHM. Moreover, in order to illustrate the potential of the application of approach for monitoring of structural systems an optimal strategy for SHM is determined for a system comprised of three welded details.
As more offshore wind parks are commissioned, the focus will inevitably shift from a planning, construction, and warranty focus to an operation, maintenance, and investment payback focus. In this latter case, both short-term risks associated with wind turbine component assemblies, and long-term risks related to integrity of the support structure, are highly important. This research focuses on the role of condition monitoring to lower costs and risks associated with short-term reliability and long-term asset integrity. This enables comparative estimates of the life cycle costs and reduction in uncertainty, both of which are of value to investors.
This paper addresses the quantification of the value of damage detection system and algorithm information on the basis of Value of Information (VoI) analysis to enhance the benefit of damage detection information by providing the basis for its optimization before it is performed and implemented. The approach of the quantification the value of damage detection information builds upon the Bayesian decision theory facilitating the utilization of damage detection performance models, which describe the information and its precision on structural system level, facilitating actions to ensure the structural integrity and facilitating to describe the structural system performance and its functionality throughout the service life. The structural system performance is described with its functionality, its deterioration and its behavior under extreme loading. The structural system reliability given the damage detection information is determined utilizing Bayesian updating. The damage detection performance is described with the probability of indication for different component and system damage states taking into account type 1 and type 2 errors. The value of damage detection information is then calculated as the difference between the expected benefits and risks utilizing the damage detection information or not. With an application example of the developed approach based on a deteriorating Pratt truss system, the value of damage detection information is determined,demonstrating the potential of risk reduction and expected cost reduction.
Reclassification of bridges, i.e., a change in load rating, using reliability-based methods and a direct update with proof load information has been presented by many authors. However, bridge reclassification has hardly been studied from a decision analytic perspective, i.e., with quantification of the risks and benefits of different classification choices, and the expected benefit gain from proof loading. We derive, explain and exemplify a decision analytic approach for bridge reclassification along with models for (1) elastic and ultimate capacity and their adaptation with proof load information, (2) proof load information with classification outcomes accounting for target reliabilities and, (3) utilities including socio-economic benefits from reclassification. The approach and models are exemplified with a case study based on reclassification of bridges with a low existing classification. Decision rules, for practical use by a highway authority to find the optimal classification, are identified and documented based on: (1) the measurement of the capacity at elastic limit by proof loading, (2) the bridge reclassification benefits, and, (3) the required annual reliability level. From a Value of Information analysis, it is concluded that the proof load information is highly valuable for reclassification in cases of high socio-economic benefits and high reliability requirements.
Proof load testing may be performed to confirm the reliability of the bridge for an existing classification or to prove the reliability for a higher classification. In this paper, a probabilistic decision analysis approach is applied to the scenario for the evaluation of target proof load in the situation where information on the bridge resistance model is lacking. In this case, the resistance model is established by proof loading and taking very basic prior knowledge into account. The decision scenario is modelled in the context of the proof load test planner who shall choose the required load level for assessment of a bridge. The choice of the load level depends on the risks due to the testing and the expected benefit gain from the test. Information acquired about the loading response from monitoring during the proof load testing is modelled by taking basis in the model uncertainty formulation. The optimal proof load level for classification of a single lane, simply supported bridge of 8m span subjected to live load from very heavy (gross weight > 80 tons) transport vehicles was calculated. The optimal proof load level was identified as leading to a positive expected benefit gain to the decision maker while also satisfying target reliability criteria for remaining service life. The analysis was performed for the evaluation of bridge performance with respect to five classifications of very heavy transport vehicles with different vehicle weights and configurations.
To ensure a high operational reliability of future generations of offshore wind conversion systems (OWEC) with economically acceptable repair and maintenance efforts, comprehensive diagnosis and supervision concepts are required. Automatic monitoring systems will be an essential part of such concepts. Because of the fact, that during operation there will be static and dynamic interaction between the components 'structure', 'machinery' and 'blades' it is necessary to develop the monitoring techniques in an overall concept. These monitoring systems are supposed to be applied for the design and testing as well as for the operation and maintenance phases. The used methods are focused on the design requirements for the structure, which are stated in the respective standards and certification guidelines. For the validation of the design, methods are specified which would be also applicable for SHM in the operating condition, e.g. for the evaluation of the structural conditon possibly after the occurrence of damages or changes. The further task consists in the realization of condition monitoring for all components, aiming at early damage detection and the observation of the damage development and its evaluation. Here the task consists of determining with assessment procedures the optimum time for maintenance actions to be carried out.
A method to determine the influencing parameters of a structural and damage detection system is proposed based on the value of Information analysis. The value of information analysis utilizes the Bayesian pre-posterior decision theory to quantify the value of damage detection system for the structural integrity management during service life. First, the influencing parameters of the structural system, such as deterioration type and rate are introduced for the performance of the prior probabilistic system model. Then the influencing parameters on the damage detection system performance, including number of sensors, sensor locations, measurement noise, and the Type-I error are investigated. The preposterior probabilistic model is computed utilizing the Bayes’ theorem to update the prior system model with the damage indication information. Finally, the value of damage detection system is quantified as the difference between the maximum utility obtained in pre-posterior and prior analysis based on the decision tree analysis, comprising structural probabilistic models, consequences, as well as benefit and costs analysis associated with and without monitoring. With the developed approach, a case study on a statically determinate Pratt truss bridge girder is carried out to validate the method. The analysis shows that the deterioration rate is the most sensitive parameter on the effect of relative value of information over the whole service life. Furthermore, it shows that more sensors do not necessarily lead to a higher relative value of information; only specific sensor locations near the highest utilized components lead to a high relative value of information; measurement noise and the Type-I error should be controlled and be as small as possible. An optimal sensor employment with highest relative value of information is found. Moreover, it is found that the proposed method can be a powerful tool to develop optimal service life maintenance strategies—before implementation—for similar bridges and to optimize the damage detection system settings and sensor configuration for minimum expected Costs and risks.