Filtern
Erscheinungsjahr
Dokumenttyp
- Beitrag zu einem Tagungsband (22)
- Beitrag zu einem Sammelband (2)
- Zeitschriftenartikel (1)
- Buchkapitel (1)
- Corrigendum (1)
- Dissertation (1)
Sprache
- Englisch (28) (entfernen)
Referierte Publikation
- nein (28) (entfernen)
Schlagworte
- Value of information (5)
- Integrated monitoring system (3)
- Offshore wind turbines (3)
- Structural reliability (3)
- Condition monitoring (2)
- Damage detection (2)
- Data management (2)
- Fatigue (2)
- Fire (2)
- Limit values (2)
Organisationseinheit der BAM
The Influence of brittle Daniels system characteristics on the value of load monitoring information
(2016)
This paper addresses the influence of deteriorating brittle Daniels system characteristics on the value of structural health monitoring (SHM). The value of SHM is quantified as the difference between the life cycle benefits with and without SHM. A value of SHM analysis is performed within the framework of the Bayesian pre-posterior decision theory and requires (1) structural performance modelling and prediction, (2) structural integrity management models, (3) the (pre-posterior) modelling of SHM and (4) the coupling of SHM and the structural performance models. The pre-posterior decision theoretical framework facilitates that the value of SHM can be quantified before the SHM system is quantified and before data are acquired. The results of this study support decisions to select structural systems for which the SHM strategy load monitoring is optimal.
As more offshore wind parks are commissioned, the focus will inevitably shift from a planning, construction, and warranty focus to an operation, maintenance, and investment payback focus. In this latter case, both short-term risks associated with wind turbine component assemblies, and long-term risks related to integrity of the support structure, are highly important. This research focuses on the role of condition monitoring to lower costs and risks associated with short-term reliability and long-term asset integrity. This enables comparative estimates of the life cycle costs and reduction in uncertainty, both of which are of value to investors.
This paper describes a structural reliability analysis utilizing monitoring data in the ultimate limit state with consideration of the uncertainties of the monitoring procedure. For this purpose the uncertainties of the monitoring data are modeled utilizing a new framework for the determination of measurement uncertainties. The approach is based on a process equation and Statistical models of observations for the derivation of a posterior measurement uncertainty by Bayesian updating. This facilitates the quantification of a measurement uncertainty using all available data of the measurement process. For the reliability analysis in the ultimate limit state, monitoring data can be utilized as a loading model Information and as proof loading, i.e. resistance model Information. Both approaches are discussed with generic examples and it is shown that the modeling of monitoring data in a reliability analysis can result in a reduction of uncertainties and as a consequence in the reduction of the probability of failure. Furthermore, the proof loading concept is developed further to account for the uncertain characteristic of proof loading due to the measurement uncertainties which is consistent with the framework for the determination of measurement uncertainties. These approaches and findings can be utilized for the assessment of structures for life cycle extension and the design of monitoring Systems.
Structural Health Monitoring (SHM) systems are designed for assisting owners and operators with information and forecasts concerning the fitness for purpose of structures and building systems. The benefit associated with the implementation of SHM may in some cases be intuitively anticipated or proven by past experiences but in general there appears to be no rational or systematic approach for assessing the value of SHM systems a-priory to their implementation. The present paper addresses the assessment of the value of SHM with basis in structural risk assessments and the Bayesian pre-posterior decision analysis. The quantification of the value of SHM builds upon the quantification of the value of information (VoI) or rather the benefit of monitoring. The suggested approach involves a probabilistic representation of the loads and environmental conditions acting on structures as well as their responses and performances over their life-cycle. In addition, the quality of monitoring and the performance of possible remedial actions triggered by monitoring results are modeled probabilistically.The consequences accounted for, in principle include all consequences associated with the performance of the structure over its life-cycle as well as the costs associated with monitoring and possible remedial actions. The suggested approach is illustrated through two case studies concerning the monitoring of welded details in steel structures subjected to fatigue loading. The case studies address the effect of the uncertainty associated with the performance of SHM on the value of SHM. Moreover, in order to illustrate the potential of the application of approach for monitoring of structural systems an optimal strategy for SHM is determined for a system comprised of three welded details.
Inspections are an efficient means of enhancing the reliability of redundant structural Systems subjected to fatigue. To investigate the effect of such inspections, we represent the deterioration state of a Daniels System by means of a probabilistic fatigue crack growth model of all elements, which considers stochastic dependence among element fatigue behavior. We include inspection results in the calculation of the System collapse probability through Bayesian updating of the System deterioration state. Based on this approach, we calculate the collapse probability of a deteriorating Daniels System conditional on different inspection strategies in terms of inspection coverage and inspection times. The acceptability of an inspection strategy is verified by comparing the calculated collapse probabilities with maximum acceptable System failure probabilities. This study is a Step towards identifying optimal inspection strategies for redundant structural Systems subjected to fatigue.