Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (26)
- Beitrag zu einem Tagungsband (14)
- Beitrag zu einem Sammelband (2)
- Corrigendum (1)
- Posterpräsentation (1)
Schlagworte
- Ringversuch (7)
- Gefahrgut (5)
- Gefahrstoff (5)
- Prüfmethode (5)
- Qualitätssicherung (5)
- Interface (4)
- Validierung (4)
- Adhäsion (3)
- Dangerous goods (3)
- Haftung (3)
- Hazardous substances (3)
- Quality assurance (3)
- Reibung (3)
- Spurenverunreinigungen (3)
- Test method (3)
- Validation (3)
- Verbundwerkstoffe (3)
- Cell proliferation (2)
- Exocytosis (2)
- Femtosecond laser ablation (2)
- Gold nanoparticles (2)
- Incorrect classification (2)
- Interlaboratory test (2)
- Measurement uncertainty (2)
- NEXAFS (2)
- NO2 (2)
- Quantum dots (2)
- Thermoplast (2)
- Uptake studies (2)
- Verstärkungsfaser (2)
- 1,3,4-Oxadiazole (1)
- Adhesion (1)
- Azodicarbonamid (1)
- CCS (1)
- CO2-storage (1)
- Calcium cobaltite (1)
- Carbon (1)
- Carbon capture and storage (1)
- Carbon fibers (1)
- Carbon fibres (1)
- Carbon nanotube CNT (1)
- Coating (1)
- Coherent scattering (1)
- Contact angle (1)
- Coordination polymers (1)
- Corrosion (1)
- Crystal structure (1)
- DLS (1)
- Deflagrationen (1)
- Deflagrationsgeschwindigkeit (1)
- Discotic liquid crystals (1)
- Druckanstiegsrate (1)
- Electron microscopy (1)
- FT-IR-Spektroskopie (1)
- Fiber properties (1)
- Fibre - matrix bond (1)
- Fluorescence (1)
- Fluorescence labeling (1)
- Fluorination (1)
- Fluorination kinetics (1)
- Free electron lasers (1)
- Functionalized Au nanoparticles (1)
- Gas phase fluorination of PE (1)
- Gaschromatographie (1)
- Geschlossenes System (1)
- Heat treatment (1)
- Hydrogen bonds (1)
- IR (1)
- Interfacial strength (1)
- Interlaboratory comparison (1)
- LTCC (1)
- Laser-induced periodic surface structures (1)
- Layer-by-layer deposition (1)
- Liquid Crystals (1)
- Liquid crystal (1)
- Messmethode (1)
- Metal matrix (1)
- Metallo-supramolecular chemistry (1)
- Methan (1)
- Methodenvalidierung (1)
- Meßverfahren (1)
- Molecular conformation (1)
- Molecular dynamics simulation (1)
- Molecular-dynamics (1)
- Multilayer (1)
- Nano-materials (1)
- New and emerging technologies and materials (1)
- OMBD (1)
- Oxygen-containing functionalities (1)
- Passive components and circuits (1)
- Phase shifter (1)
- Photoelectron spectroscopy (XPS) (1)
- Pipeline (1)
- Polymer matrix (1)
- Pressure-assisted sintering (1)
- Pull-out (1)
- Pull-out test (1)
- Purification (1)
- Raman imaging (1)
- Raman spectroscopy (1)
- Reinforced composites (1)
- Round robin test (1)
- SEM (1)
- Scherfestigkeit (1)
- Schubfestigkeit (1)
- Self-assembly (1)
- Semiconductor (1)
- Shark profile (1)
- Shark profiles (1)
- Shear strength (1)
- Silicon (1)
- Simulation (1)
- Steel (1)
- Structural characterization (1)
- Surface area (1)
- Surface functional groups (1)
- TEM (1)
- Tensile test inside a TEM (1)
- Thermoelectric oxide (1)
- Thermoplaste (1)
- Time-resolved coherent XUV scattering (1)
- ToF-SIMS (1)
- Tunable antenna (1)
- UV-vis (1)
- Verifizierung (1)
- Vesicles (1)
- Weathering (1)
- X-ray Absorption Spectroscopy (1)
- XPS (1)
Organisationseinheit der BAM
- 2 Prozess- und Anlagensicherheit (6)
- 2.0 Abteilungsleitung und andere (6)
- 1 Analytische Chemie; Referenzmaterialien (2)
- 1.2 Biophotonik (2)
- 6 Materialchemie (2)
- 6.6 Physik und chemische Analytik der Polymere (2)
- 2.1 Sicherheit von Energieträgern (1)
- 2.2 Prozesssimulation (1)
- 5 Werkstofftechnik (1)
- 5.4 Multimateriale Fertigungsprozesse (1)
Laboratory test results are of vital importance for correctly classifying and labelling chemicals as “hazardous” as defined in the UN Globally Harmonized System (GHS) / EC CLP Regulation or as “dangerous goods” as defined in the UN Recommendations on the Transport of Dangerous Goods. Interlaboratory tests play a decisive role in assessing the reliability of laboratory test results. Interlaboratory tests performed over the last 10 years have examined different laboratory test methods. After analysing the results of these interlaboratory tests, the following conclusions can be drawn:
1. There is a need for improvement and validation for all laboratory test methods examined.
2. To avoid any discrepancy concerning the classification and labelling of chemicals, the use of validated laboratory test methods should be state of the art, with the results accompanied by the measurement uncertainty and (if applicable) the probability of incorrect classification.
This paper addresses the probability of correct/incorrect classification (for example, as dangerous goods) on the basis of the measurement deviation obtained from interlaboratory tests performed by the Centre for quality assurance for testing of dangerous goods and hazardous substances (CEQAT-DGHS) to validate laboratory test methods. This paper outlines typical results (e.g. so-called “Shark profiles” – the probability of incorrect classification as a function of the true value estimated from interlaboratory test data) as well as general conclusions and steps to be taken to guarantee that laboratory test results are fit for purpose and of high quality.
In order to understand the role of dipolar interactions vs. H-bonding, a series of hydrazones were synthesised from 4-alkoxy-, 3,4-dialkoxy- or 3,4,5-trialkoxybenzaldehydes and phenyl, bromo- or nitrophenylhydrazine, respectively. Their mesomorphic properties were investigated by differential scanning calorimetry (DSC), polarising optical microscopy (POM), X-ray diffraction (WAXS, SAXS) and compared with known members. Only those hydrazones derived from 3,4,5-trisalkoxybenzaldehyde and either meta, meta-dinitro- or ortho, para-dinitrophenylhydrazine displayed hexagonal columnar mesophases. All other derivatives were non-mesomorphic, even when H-bonds were present. Dipole moments of the various nitro-substituted hydrazones were experimentally determined by dielectric measurements and supported by theoretical DFT calculations, which indicated that the mesophase formation is mostly governed by strong dipole moment and further enforced by intramolecular H-bonding.
A simple method of creating defined PMMA and poly (MMA-co-Cz) electrocoatings on carbon fibres is described. The electrodeposition of poly methylmethacrylate (PMMA) onto unsized, unmodified carbon fibres was performed by simple constant current electrolyses of methylmethacrylate (MMA) monomer in dimethylformamide (DMF) solutions and the pure liquid monomer using sodium nitrate and lithium perchlorate as supporting electrolytes. The presence of polymeric coatings successfully attached to the carbon fibres was verified by scanning electron microscopy and photoelectron spectroscopy (XPS).
Performing the electrolysis in dilute MMA in DMF solutions ([MMA] < 5 M) results in the deposition of powder-like polymer on the carbon fibre electrodes. Increasing the MMA concentration in the DMF solution results in a homogeneous PMMA coating of the carbon fibres. The degree of grafting or coating increases with increasing MMA concentration, except when pure MMA is used without solvent.
The adhesive strength between the electrocoated carbon fibres and a PMMA matrix was determined using the single fibre pull-out test. It was found that the interfacial fracture behaviour of all carbon fibre/PMMA model composites is rather brittle. The adhesion strength between the unmodified carbon fibres and the PMMA matrix was equal to the cohesive strength of the polymer matrix itself. Nevertheless, the electrodeposition of thin and homogeneous PMMA coatings resulted in much improved adhesion strengths.