Filtern
Erscheinungsjahr
Dokumenttyp
Sprache
- Englisch (22)
- Deutsch (9)
- Mehrsprachig (1)
Schlagworte
- VOC (12)
- Emissionen (7)
- Emission test chamber (6)
- SVOC (6)
- Bauprodukte (5)
- Emissionsmesskammern (4)
- Interlaboratory study (4)
- VOC emission (4)
- AgBB (3)
- Chamber test (3)
Organisationseinheit der BAM
Paper des Monats
- ja (1)
The European biocides directive (98/8/EG) demand the control of emissions into the envi-ronment like soil, water and air. In this study a method for measuring the input of biocides into the indoor air from materials should be developed. The emission of two products containing biocides (plastic foil, wool carpet) and six different types of biocide containing formulations applied on wood or ceramic tiles were investigated in 20 or 23 l glass emission chambers. Each chamber test was performed over a period of 100 up to 200 days. SVOC show totally different emission curves in chamber tests compared to volatile organic com-pounds (VOC). They reach their maximum value after some days or weeks. Thus a period of 3 months is sometimes necessary for exact measurements. Area specific emission rates (SERa in µg/m²h) for permethrin (0.006), propiconazole (0.2), dichlofluanid (1.5), tolylfluanid (1.2), octylisothiazolinone (2.5) and for iodpropinylbutyl-carbamat (1.7) were determined.
The emission levels of high boiling brominated (BFR) and phosphoric (POC) flame retardants (FR) in different materials were examined. For the determination of the emission rate the tests were done in different emission test chambers and cells under standard conditions (23 C, 50% RH and fixed area specific air flow rates). Selected products, e.g. printed circuit boards, were investigated at elevated temperature (e.g. 60 C) to simulate working conditions. Applied analytical techniques for the air samples adsorbed on polyurethane foam (PUF) are soxhlet and ultrasonic extraction. Different conditions were used to analyse the FR via GC-MS. Based on the first results it could be demonstrated that the emission depends on material density and surface condition. The concentrations over time obtained for tris(3-chloropropyl)-phosphate, e.g., from emission test chamber and cell show a good correlation, partly the measured concentration are different. Sampling at elevated temperature gives higher concentrations.
Do particleboards produced with recycled wood contribute to indoor air pollution with biocides?
(2003)
Vor dem Hintergrund der notwendigen Revision der Kriterien zur Vergabe des Gütezeichens "Blauer Engel" für Laserdrucker, Kopierer und Multifunktionsgeräte mussten auch die Prüfmethoden angepasst werden, da die alten Verfahren nicht mehr die heutigen Anforderungen der Emissionsmessung erfüllen. In diesem Zusammenhang wurde auch das unterschiedliche Emissionsverhalten von Hardcopy-Geräten auf Grund der verschiedenen und nicht miteinander vergleichbaren Prüfverfahren heftig diskutiert. Aus diesen Gründen wurde ein neues Prüfverfahren entwickelt, mit dem eine verlässliche und reproduzierbare Prüfung der Emissionsraten von Staub, Ozon und flüchtiger organischer Verbindungen auf der Basis des ECMA (European Computer Manufacturer Association) Standards 328 möglich ist. Dazu wurden neun verschiedene Geräte unter verschiedenen Bedingungen untersucht. Als ein Ergebnis dieser Studie wurden neue Kriterien zur Vergabe des "Blauen Engels" für Kopierer, Drucker und Multifunktionsgeräte festgelegt.