Filtern
Dokumenttyp
- Beitrag zu einem Sammelband (2)
- Beitrag zu einem Tagungsband (1)
- Vortrag (1)
- Posterpräsentation (1)
- Preprint (1)
Referierte Publikation
- nein (6) (entfernen)
Schlagworte
- Beton (2)
- Betonangriff (2)
- Dauerhaftigkeit (2)
- Nanophotonics (2)
- Piezoelectricity (2)
- Semiconductor nanostructures (2)
- Spontaneous polarization (2)
- Säureangriff (2)
- EBSD (1)
- Heat treatment (1)
Organisationseinheit der BAM
Eingeladener Vortrag
- nein (1)
The quenching and partitioning (Q&P) heat treatment enables a higher deformability of high strength martensitic steels. The Q&P heat treatment was applied on the martensitic stainless steel 1.4034 (X46Cr13) to study the influence of partitioning time. Therefore, extensive characterizations of the mechanical properties, focussing on the materials behaviour under different mechanical load scenarios, were performed. A comprehensive analysis of the microstructural evolution was per-formed for different heat treatment and mechanical loading states. A complete solution of chromium carbides was detected to be a first requirement for successful Q&P heat treatment. The comparison of common quenching and tempering with the Q&P heat treatment verifies the extensively enhanced materials strength whereat the formability is still acceptable. The microstructural reason was detected to be an increasing aus-tenite fraction due to austenite reversion at subgrain boundaries of martensite besides the stabilising of retained austenite. Further a distinctive strength differential effect was observed.
Chemischer Angriff auf Betonbauwerke - Bewertung des Angriffsgrads und geeignete Schutzprinzipien
(2014)
In verschiedenen Bereichen des Betonbaus ist Beton einem chemischen Angriff von außen ausgesetzt, der die Dauerhaftigkeit des betreffenden Bauteils bzw. des gesamten Bauwerks beeinträchtigen kann. Für einen chemischen Angriff in natürlichen Böden und Grundwässern bestehen normative Vorgaben in DIN 4030-1 [R10] bzw. DIN 1045-2 [R19], um den Angriffsgrad anhand der Art und Konzentration der angreifenden Stoffe in Expositionsklassen XA1 (schwach angreifend) bis XA3 (stark angreifend) einzustufen. Hinsichtlich weiterer maßgeblicher Einflussfaktoren wird an dieser Stelle nicht näher differenziert, ob und inwieweit die Regelungen für Böden und Grundwässer auch auf andere Bereiche mit chemischem Angriff auf Beton zu übertragen sind, ist stets im Einzelfall zu überprüfen. Ebenfalls sind die zu treffenden Maßnahmen über die Vorgaben der DIN EN 206-1/DIN 1045-2 [R19] hinaus anwendungsspezifisch festzulegen. Der Hauptausschuss Baustofftechnik (HABT) des DBV hat daher den Arbeitskreis "Chemischer Angriff auf Beton" beauftragt, dieses Merkblatt zu erarbeiten, das Hilfestellung bei der Bewertung einer projektspezifischen chemischen Angriffssituation auf Beton sowie bei der Planung und Ausführung von Schutzprinzipien leisten soll.
ln den letzten Jahren wurden diverse Prüfverfahren und Methoden entwickelt, um die Leistungsfähigkeit von Beton bzw. Bindemittel hinsichtlich des Widerstands gegenüber betonaggressiven Einwirkungen beurteilen zu können. Ein wesentliches Ziel von Prüfverfahren zur Beurteilung der Dauerhaftigkeit von Baustoffen ist, die im Laufe der Nutzungsdauer zu erwartenden Einwirkungen auf den Baustoff realitätsnah abzubilden. Dazu sind die Prüfparameter auf die im jeweiligen Anwendungsbereich vorherrschenden Umgebungs- und Randbedingungen anzupassen. Daneben sind auch die Bewertungskriterien individuell unter Berücksichtigung der im Einzelfall geforderten Nutzungsdauer eines Bauwerks festzulegen. Eine systematische Zuordnung von adäquaten Prüfverfahren bzw. Prüfparametem und Bewertungskriterien für die verschiedenen Anwendungsbereiche im Betonbau, in denen betonaggressive Einwirkungen auftreten, ist mit Ausnahme von Einzelfällen bislang nicht vorhanden. Daneben stellt sich in der Praxis immer wieder das Problem, das Angriffspotenzial der Umgebung eines Bauwerks (prüftechnisch) zu erfassen und zu bewerten.
Der Hauptausschuss Baustofftechnik des DBV hat daher den Arbeitskreis „Chemischer Angriff auf Beton“ beauftragt, dieses Merkblatt zu erarbeiten, das auf Basis von einschlägigen Erfahrungen der Baupraxis und wissenschaftlichen Erkenntnissen Grundsätze und bewährte Methoden zur Beurteilung der Einwirkungs- und Widerstandsseite beim chemischen Angriff auf Beton aufzeigt und diesbezüglich Hinweise für verschiedene Anwendungsbereiche im Betonbau liefert.
Recently, we suggested an unconventional approach [the so-called Internal-Field-Guarded-Active-Region Design (IFGARD)] for the elimination of the crystal polarization field induced quantum confined Stark effect (QCSE) in polar semiconductor heterostructures. And in this work, we demonstrate by means of micro-photoluminescence techniques the successful tuning as well as the elimination of the QCSE in strongly polar [000-1] wurtzite GaN/AlN nanodiscs while reducing the exciton life times by more than two orders of magnitude. The IFGARD based elimination of the QCSE is independent of any specific crystal growth procedures. Furthermore, the cone-shaped geometry of the utilized nanowires (which embeds the investigated IFGARD nanodiscs) facilitates the experimental differentiation between quantum confinement- and QCSE-induced emission energy shifts. Due to the IFGARD, both effects become independently adaptable.
One of the most significant limitations for the quantum efficiency of group III-nitride based light emitters is the spatial electron-hole separation due to the quantum-confined Stark effect (QCSE). To overcome this problem, Hönig et al. [1] proposed a novel concept, the Internal-Field-Guarded-Active-Region Design (IFGARD), which suppresses the QCSE for wurtzite crystals in the [0001] direction. Here, we show how encapsulating the active region by additional guard layers results in a strong reduction of the built-in electric field in c-plane wurtzite nanostructures. Even more importantly, we demonstrate the first experimental evidence for the successful realization of an IFGARD structure based on GaN/AlN heterostructures embedded in GaN nanowires. By means of power-dependent and time-resolved µ-photoluminescence (µ-PL) we experimentally proof the validity of the unconventional IFGARD structure. We managed to tune the emission of 4-nm-thick GaN nano-discs up to 3.32 eV at low excitation powers, which is just 150 meV below the bulk GaN bandgap. Our results demonstrate an almost complete elimination of the QCSE in comparison to conventional structures which show approximately 1 eV red-shifted emission. The suppression of the QCSE results in a significant increase of the radiative exciton decay rates by orders of magnitude and demonstrates the potential of IFGARD structures for future light sources based on polar heterostructures.
[1] Hönig et al., Phys. Rev. Applied 7, 024004 (2017)
The lack of traceability to meter of X-ray Computed Tomography (CT) measurements still hinders a more extensive acceptance of CT in coordinate metrology and industry. To ensure traceable, reliable, and accurate measurements, the determination of the task-specific measurement uncertainty is necessary. The German guideline VDI/VDE 2630 part 2.1 describes a procedure to determine the measurement uncertainty for CT experimentally by conducting several repeated measurements with a calibrated test specimen. However, this experimental procedure is cost and effort intensive. Therefore, the simulation of dimensional measurement tasks conducted with X-ray computed tomography can close these drawbacks. Additionally, recent developments towards a resource and cost-efficient production (“smart factory”) motivate the need for a corresponding numerical model of a CT system (“digital twin”) as well. As there is no standardized procedure to determine the measurement uncertainty of a CT system by simulation at the moment, the project series CTSimU was initiated, aiming at this gap. Concretely, the goal is the development of a procedure to determine the measurement uncertainty numerically by radiographic simulation. The first project (2019-2022), "Radiographic Computed Tomography Simulation for Measurement Uncertainty Evaluation - CTSimU" developed a framework to qualify a radiographic simulation software concerning the correct simulation of physical laws and functionalities. The most important outcome was a draft for a new guideline VDI/VDE 2630 part 2.2, which is currently under discussion in the VDI/VDE committee. The follow-up project CTSimU2 "Realistic Simulation of real CT systems with a basic-qualified Simulation Software" will deal with building and characterizing a digital replica of a specific real-world CT system. The two main targets of this project will be a toolbox including methods and procedures to configure a realistic CT system simulation and to develop tests to check if this replica is sufficient enough. The result will be a draft for a follow-up VDI/VDE guideline proposing standardized procedures to determine a CT system's corresponding characteristics and test the simulation (copy) of a real-world CT system which we call a "digital twin".