Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (26)
- Beitrag zu einem Tagungsband (14)
- Beitrag zu einem Sammelband (2)
- Corrigendum (1)
- Posterpräsentation (1)
Schlagworte
- Ringversuch (7)
- Gefahrgut (5)
- Gefahrstoff (5)
- Prüfmethode (5)
- Qualitätssicherung (5)
- Interface (4)
- Validierung (4)
- Adhäsion (3)
- Dangerous goods (3)
- Haftung (3)
Organisationseinheit der BAM
- 2 Prozess- und Anlagensicherheit (6)
- 2.0 Abteilungsleitung und andere (6)
- 1 Analytische Chemie; Referenzmaterialien (2)
- 1.2 Biophotonik (2)
- 6 Materialchemie (2)
- 6.6 Physik und chemische Analytik der Polymere (2)
- 2.1 Sicherheit von Energieträgern (1)
- 2.2 Prozesssimulation (1)
- 5 Werkstofftechnik (1)
- 5.4 Multimateriale Fertigungsprozesse (1)
Polyethylene foils, used as greenhouse foils stabilized with various types of sterically hindered amine light stabilizers (HALS), showed an extraordinary prolonged lifetime on exposure to natural or artificial weathering if a gas-phase fluorination under low-pressure conditions was applied. The fluorination was performed using F2/N2 mixtures and provided ca. 50 F/100 C (fluorination degree ap25%). The lifetimes of fluorinated PE foils on exposure to artificial or natural weathering were increased at least by a factor of 2-4 as measured in terms of tensile strength and elongation at break.
An advanced equipment for single-fibre pull-out test designed to monitor the fracture process
(1995)
Pull-out of Single Fibres
(1994)
Atmospheric-plasma fluorination was used to introduce fluorine functionalities onto the surface of carbon fibers without affecting their bulk properties. The interfacial adhesion between atmospheric-plasma-fluorinated carbon fibers and poly(vinylidene fluoride) (PVDF) was studied by means of direct wetting measurements and single fiber pullout tests. Measured contact angles of PVDF melt droplets on modified carbon fibers show that short exposure times of carbon fibers to atmospheric-plasma fluorination (corresponding to a degree of surface fluorination of F/C = 0.01 (1.1%)) leads to improved wettability of the fibers by PVDF melts. The apparent interfacial shear strength as a measure of practical adhesion, determined by the single-fiber pullout test, increases by 65% under optimal treatment conditions. The improved practical adhesion is not due to the formation of transcrystalline regions around the fibers or a change of the bulk matrix crystallinity or to an increased surface roughness; it seems to be due to the compatibilization of the interface caused of the atmospheric-plasma fluorination of the carbon fibers.
A novel coordination oligo/polymer is synthesized by metal-directed self-assembly from equimolar amounts of the (dppp)M(OTf)2 precursor complexes (dppp = bis-(diphenylphosphino)-propane, OTf = triflate; M = PdII or M = PtII) and banana-shaped bidentate dipyridyl ligands. The assemblies were characterized by ESI mass spectrometry and NMR spectroscopy. The analysis of the cloudy suspension prepared by dissolving the coordination polymer in aqueous methanol solutions indicates nanosized spherical objects to form. Evidence for vesicle formation from these metallo-supramolecular oligomers comes from (cryogenic) transmission electron microscopy (TEM, cryo-TEM). Atomic force microscopy revealed stable nanospheres on hydrophilic mica and monolayer formation on hydrophobic highly oriented pyrolitic graphite (HOPG) substrates. On mica, also torus-shaped object were observed, which are rationalized by vesicles that opened during the drying procedure and released the internal solvent. Elemental analysis of the nanoassemblies by X-ray photoelectron spectroscopy (XPS) indicates uncoordinated and coordinated pyridines in the coordination polymers that form the nanospheres. Various control experiments using different metal centers and modified ligands support the conclusions.
The molecular mobility of a MOF-5 metal–organic framework was investigated by broadband dielectric spectroscopy. Three relaxation processes were revealed. The temperature dependence of their relaxation rates follows an Arrhenius law. The process observed at lower temperatures is attributed to bending fluctuations of the edges of the cages involving the Zn–O clusters. The processes ('region II') at higher temperatures were assigned to fluctuations of phenyl rings in agreement with the NMR data found by Gould et al. (J. Am. Chem. Soc. 2008, 130, 3246). The carboxylate groups might also be involved. The rotational fluctuations of the phenyl rings leading to the low frequency part of relaxation region II might be hindered either by some solvent molecules entrapped in the cages or by an interpenetrated structure and have a broad distribution of activation energies. The high frequency part of region II corresponds nearly to a Debye-like process: This is explained by a well-defined structure of empty pores.
Laboratory test results are of vital importance for correctly classifying and labelling chemicals as “hazardous” as defined in the UN Globally Harmonized System (GHS) / EC CLP Regulation or as “dangerous goods” as defined in the UN Recommendations on the Transport of Dangerous Goods. Interlaboratory tests play a decisive role in assessing the reliability of laboratory test results. Interlaboratory tests performed over the last 10 years have examined different laboratory test methods. After analysing the results of these interlaboratory tests, the following conclusions can be drawn:
1. There is a need for improvement and validation for all laboratory test methods examined.
2. To avoid any discrepancy concerning the classification and labelling of chemicals, the use of validated laboratory test methods should be state of the art, with the results accompanied by the measurement uncertainty and (if applicable) the probability of incorrect classification.
This paper addresses the probability of correct/incorrect classification (for example, as dangerous goods) on the basis of the measurement deviation obtained from interlaboratory tests performed by the Centre for quality assurance for testing of dangerous goods and hazardous substances (CEQAT-DGHS) to validate laboratory test methods. This paper outlines typical results (e.g. so-called “Shark profiles” – the probability of incorrect classification as a function of the true value estimated from interlaboratory test data) as well as general conclusions and steps to be taken to guarantee that laboratory test results are fit for purpose and of high quality.
Novel approaches of tunable devices for millimeter wave applications based on liquid crystal (LC) are presented. In the first part of the paper, a novel concept of a tunable LC phase shifter realized in Low Temperature Cofired Ceramics technology is shown while the second part of the paper deals with a tunable high-gain antenna based on an LC tunable reflectarray. The reflectarray features continuously beam scanning in between ±25°. Also first investigations on radiation hardness of LCs are carried out, indicating that LCs might be suitable for space applications.
Bei der Bewertung der Verlässlichkeit der im Labor gewonnenen Prüfergebnisse spielen Ringversuche eine entscheidende Rolle. Die Bundesanstalt für Materialforschung und -prüfung (BAM) unterstützt deshalb den weiteren Ausbau des Ringversuchsprogramms des im Jahr 2007 gegründeten Kompetenzzentrums zur Qualitätssicherung für Prüfungen von Gefahrgütern und Gefahrstoffen auf physikalische Gefahren (Centre for quality assurance for testing of dangerous goods and hazardous substances, CEQAT-DGHS).
Bei allen bisher untersuchten Prüfmethoden besteht ein Verbesserungsbedarf. Die RV müssen daher zunächst auf die Methodenentwicklung, -verbesserung und -validierung abzielen und nicht auf Leistungstests.
Bei der Bewertung der Verlässlichkeit der im Labor gewonnenen Prüfergebnisse spielen Ringversuche eine entscheidende Rolle. Die Bundesanstalt für Materialforschung und –prüfung (BAM) unterstützt deshalb den weiteren Ausbau des Ringversuchsprogramms des im Jahr 2007 gegründeten Kompetenzzentrums zur Qualitätssicherung für Prüfungen von Gefahrgütern und Gefahrstoffen auf physikalische Gefahren (Centre for quality assurance for testing of dangerous goods and hazardous substances, CEQAT-DGHS).
Bei allen bisher untersuchten Prüfmethoden besteht ein Verbesserungsbedarf. Die RV müssen daher zunächst auf die Methodenentwicklung, -verbesserung und -validierung und auf die Bestimmung der Messunsicherheit der jeweiligen Prüfmethode abzielen und nicht auf Leistungstests.
The sintering behavior and the thermoelectric performance of Ca3Co4O9 multilayer laminates were studied, and a multilayer thermoelectric generator was fabricated. Compacts and multilayer samples with anisotropic microstructure and residual porosity were obtained after conventional sintering at 920 °C, whereas dense and isotropic multilayer samples were prepared by firing at 1200 °C and reoxidation at 900 °C. A hot-pressed sample has a dense and anisotropic microstructure. Samples sintered at 920 °C exhibit low electrical conductivity due to the low density, whereas the Seebeck coefficient is not sensitive to preparation conditions. However, thermal conductivity of multilayers is very low, and, hence acceptable ZT values are obtained. A ransversal multilayer thermoelectric generator (TMLTEG) was fabricated by stacking layers of Ca3Co4O9 green tapes, AgPd conductor printing, and co-firing at 920 °C. The TMLTEG has a power output of 3 mW at ΔT =200 K in the temperature interval of 25 °C to 300 °C.
Continuously tuneable liquid crystal based stripline phase shifter realised in LTCC technology
(2015)
This work presents the design, fabrication and measurements of a low temperature cofired ceramic (LTCC) integrated liquid crystal (LC) phase shifter. The effective permittivity of the phase shifter and therefore its differential phase shift can be tuned continuously by orienting the LC directors with electric fields. The phase-shift demonstrator is designed for Ka-band frequencies around 30 GHz and represents a stripline filled with LC, embedded inside an LTCC multilayer structure, which provides a space-qualified and hermetically-sealed LC cavity within an RF-capable material system. The total length of the device is 37 mm while the phase shifting LC section has a length of 14.6 mm. At 30 GHz it exhibits a differential phase shift of 60° with an insertion loss around 6 dB, resulting in a figure of merit around 10°/dB. An advantage is that the insertion loss is nearly independent of the tuning state of the LC. The response time of the phase shifter, depending on the desired LC orientation, is between 62 ms and 37 s.
Reliability study of a tunable ka-band SIW-phase shifter based on liquid crystal in LTCC-technology
(2014)
A tunable substrate-integrated waveguide phase shifter using low-temperature co-fired ceramic (LTCC)-technology is presented in this paper. By changing the effective permittivity in the liquid crystal (LC)-filled waveguide, the differential phase can be tuned continuously. This is achieved by means of an analog signal applied to the electrodes, surrounding the LC. The design allows for precise tuning of the differential phase, which is proven with a Monte Carlo measurement resulting in phase errors of less than 3° at 28 GHz. Besides that, the ambient temperature dependency of the module is shown. The phase shifter has a high integration level and can be included into a complete and lightweight single-phased array antenna module. The phase shifter is realized with a high level of integration which is available through the multilayer process of the LTCC. It has a length of 50 and provides a differential phase shift of more than 360° at 28 GHz. The figure of merit for tunable phase shifters is >40°/dB.
In order to understand the role of dipolar interactions vs. H-bonding, a series of hydrazones were synthesised from 4-alkoxy-, 3,4-dialkoxy- or 3,4,5-trialkoxybenzaldehydes and phenyl, bromo- or nitrophenylhydrazine, respectively. Their mesomorphic properties were investigated by differential scanning calorimetry (DSC), polarising optical microscopy (POM), X-ray diffraction (WAXS, SAXS) and compared with known members. Only those hydrazones derived from 3,4,5-trisalkoxybenzaldehyde and either meta, meta-dinitro- or ortho, para-dinitrophenylhydrazine displayed hexagonal columnar mesophases. All other derivatives were non-mesomorphic, even when H-bonds were present. Dipole moments of the various nitro-substituted hydrazones were experimentally determined by dielectric measurements and supported by theoretical DFT calculations, which indicated that the mesophase formation is mostly governed by strong dipole moment and further enforced by intramolecular H-bonding.
Bei der Bewertung der Verlässlichkeit der im Labor gewonnenen Prüfergebnisse spielen Ringversuche eine entscheidende Rolle. Die Bundesanstalt für Materialforschung und –prüfung (BAM) unterstützt deshalb den weiteren Ausbau des Ringversuchsprogramms des im Jahr 2007 gegründeten Kompetenzzentrums zur Qualitätssicherung für Prüfungen von Gefahrgütern und Gefahrstoffen auf physikalische Gefahren (Centre for quality assurance for testing of dangerous goods and hazardous substances, CEQAT-DGHS).
Bei allen bisher untersuchten Prüfmethoden besteht ein Verbesserungsbedarf. Die RV müssen daher zunächst auf die Methodenentwicklung, -verbesserung und -validierung und auf die Bestimmung der Messunsicherheit der jeweiligen Prüfmethode abzielen und nicht auf Leistungstests.
Das Deflagrationsverhalten von Feststoffen unter atmosphärischen Bedingungen wurde in der Vergangenheit eingehend untersucht. Standardmäßig wird die Deflagrationsprüfung in einem offenen System durchgeführt. Aber auch in geschlossenen Systemen ist die Deflagrationsprüfung durchführbar und sie liefert Ergebnisse, die mit den Standardmethoden vergleichbar sind. Darüber hinaus bietet die Prüfung in einem geschlossenen System den Vorteil, nicht nur die Temperatur, sondern auch den Druck messen und für die Beschreibung des Deflagrationsverlaufs heranziehen zu können.
Auch für die Prüfung in geschlossenen Systemen liegt eine Reihe an experimentellen Ergebnissen vor. Von Klais wurde veröffentlicht, dass die Deflagrationsgeschwindigkeit, beschrieben anhand der Druckanstiegsrate, mit steigendem Druck ansteigt. Vor dem Hintergrund dieser experimentellen Beobachtung wurde interpretiert, dass die Steigerung der Geschwindigkeit ihre Ursache im steigenden Umgebungsdruck findet. Es wurde weiter versucht, einen funktionalen Zusammenhang zwischen Umgebungsdruck und Deflagrationsgeschwindigkeit, ausgedrückt durch die Druckanstiegsrate, herzustellen. Dabei wurde nicht beachtet, dass neben dem Umgebungsdruck noch andere Einflussfaktoren auf die Deflagrationsgeschwindigkeit gegeben sind. Wesentlich ist hierbei die für die Reaktion zur Verfügung stehende Oberfläche, die sich bei einer lokalen, punktförmigen Anzündung mit fortschreitender Reaktionszeit vergrößert.
In diesem Beitrag wird der Einfluss des Umgebungsdrucks auf die Deflagrationsgeschwindigkeit systematisch untersucht. Zu diesem Zweck wurden Experimente bei verschiedenen Ausgangsdrücken bis zu 50 bar (abs) durchgeführt. Der Anfangsdruck, also der Druck der vor Beginn eines Experiments im Reaktionsraum herrscht, wurde schrittweise von einem Experiment zum nächsten erhöht. Für die Versuchsreihen wurden zwei Substanzen verwendet: Azodicarbonamid und ein Imidazolderivat. Diese unterscheiden sich in ihrem Deflagrationsverhalten und hinsichtlich der Gasmengenentwicklung.
Die durchgeführten Experimente haben gezeigt, dass die Deflagrationsgeschwindigkeit mit steigendem Druck zunimmt. Sowohl die Druckanstiegsrate, als auch die lineare Ausbreitungsrate sind ein gutes Maß dafür. Zwischen den beiden Kenngrößen besteht ein linearer Zusammenhang. Für eine gegebene Geometrie lässt sich die eine Kenngröße aus der anderen berechnen.
Most studies about the interaction of nanoparticles (NPs) with cells have focused on how the physicochemical properties of NPs will influence their uptake by cells. However, much less is known about their potential excretion from cells. However, to control and manipulate the number of NPs in a cell, both cellular uptake and excretion must be studied quantitatively. Monitoring the intracellular and extracellular amount of NPs over time (after residual noninternalized NPs have been removed) enables one to disentangle the influences of cell proliferation and exocytosis, the major pathways for the reduction of NPs per cell. Proliferation depends on the type of cells, while exocytosis depends in addition on properties of the NPs, such as their size. Examples are given herein on the role of these two different processes for different cells and NPs.
To study the mechanical interface behavior of single-walled carbon nanotubes (CNTs) embedded in a noble metal, we performed CNT-metal pull-out tests with in situ scanning electron microscope experiments. Molecular dynamics (MD) simulations were conducted to predict force-displacement data during pull-out, providing critical forces for failure of the system. In MD simulations, we focused on the influence of carboxylic surface functional groups (SFGs) covalently linked to the CNT. Experimentally obtained maximum forces between 10 and 102 nN in palladium and gold matrices and simulated achievable pulling forces agree very well. The dominant failure mode in the experiment is CNT rupture, although several pull-out failures were also observed. We explain the huge scatter of experimental values with varying embedding length and SFG surface density. From simulation, we found that SFGs act as small anchors in the metal matrix and significantly enhance the maximum forces. This interface reinforcement can lead to tensile stresses sufficiently high to initiate CNT rupture. To qualify the existence of carboxylic SFGs on our CNT material, we performed analytical investigation by means of fluorescence labeling of surface species and discuss the results. With this contribution, we focus on a synergy between computational and experimental approaches involving MD simulations, nano scale testing, and analytics (1) to predict to a good degree of accuracy maximum pull-out forces of single-walled CNTs embedded in a noble metal matrix and (2) to provide valuable input to understand the underlying mechanisms of failure with focus on SFGs. This is of fundamental interest for the design of future mechanical sensors incorporating piezoresistive single-walled CNTs as the sensing element.
There is a high international priority attached to activities which reduce NOx in the atmosphere. The current level of permitted emissions is typically between 50 µmol/mol and 100 µmol/mol, but lower values are expected in the future. Currently, ambient air quality monitoring regulations also require the measurement of NOx mole fractions as low as 0.2 µmol/mol. The production of accurate standards at these levels of mole fractions requires either dilution of a stable higher concentration gas standard or production by a dynamic technique, for example one based on permeation tubes.
The CCQM-K74 key comparison was designed to evaluate the level of comparability of National Metrology Institutes' measurement capabilities and standards for nitrogen dioxide (NO2) at a nominal mole fraction of 10 µmol/mol.
The measurements of this key comparison took place from June 2009 to May 2010.
Seventeen laboratories took part in this comparison coordinated by the BIPM and VSL. The key comparison reference value was based on BIPM measurement results, and the standard measurement uncertainty of the reference value was 0.042 µmol/mol.
This key comparison demonstrated that the results of the majority of the participants agreed within limits of ±3% relative to the reference value. The results of only one laboratory lay significantly outside these limits. Likewise this comparison made clear that a full interpretation of the results of the comparison needed to take into account the presence of nitric acid (in the range 100 nmol/mol to 350 nmol/mol) in the cylinders circulated as part of the comparison, as well as the possible presence of nitric acid in the primary standards used by participating laboratories.
Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/.
The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).
DatesIssue 1A (Technical Supplement 2012)
A simple method of creating defined PMMA and poly (MMA-co-Cz) electrocoatings on carbon fibres is described. The electrodeposition of poly methylmethacrylate (PMMA) onto unsized, unmodified carbon fibres was performed by simple constant current electrolyses of methylmethacrylate (MMA) monomer in dimethylformamide (DMF) solutions and the pure liquid monomer using sodium nitrate and lithium perchlorate as supporting electrolytes. The presence of polymeric coatings successfully attached to the carbon fibres was verified by scanning electron microscopy and photoelectron spectroscopy (XPS).
Performing the electrolysis in dilute MMA in DMF solutions ([MMA] < 5 M) results in the deposition of powder-like polymer on the carbon fibre electrodes. Increasing the MMA concentration in the DMF solution results in a homogeneous PMMA coating of the carbon fibres. The degree of grafting or coating increases with increasing MMA concentration, except when pure MMA is used without solvent.
The adhesive strength between the electrocoated carbon fibres and a PMMA matrix was determined using the single fibre pull-out test. It was found that the interfacial fracture behaviour of all carbon fibre/PMMA model composites is rather brittle. The adhesion strength between the unmodified carbon fibres and the PMMA matrix was equal to the cohesive strength of the polymer matrix itself. Nevertheless, the electrodeposition of thin and homogeneous PMMA coatings resulted in much improved adhesion strengths.