Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (40)
- Beitrag zu einem Tagungsband (14)
- Forschungsbericht (6)
- Sonstiges (3)
- Beitrag zu einem Sammelband (2)
- Buchkapitel (1)
- Vortrag (1)
Schlagworte
- Brückenbeläge (4)
- Fahrbahnübergänge (4)
- Asphaltbauweisen (3)
- ELISA (3)
- Ethinylestradiol (3)
- Baustoffe (2)
- CZE (2)
- LCA (2)
- LCC (2)
- LCWE (2)
Organisationseinheit der BAM
- 1 Analytische Chemie; Referenzmaterialien (8)
- 1.8 Umweltanalytik (7)
- 7 Bauwerkssicherheit (7)
- 6 Materialchemie (5)
- 6.7 Materialsynthese und Design (4)
- 7.1 Baustoffe (4)
- 4 Material und Umwelt (3)
- 1.5 Proteinanalytik (2)
- 4.1 Biologische Materialschädigung und Referenzorganismen (2)
- 7.2 Ingenieurbau (2)
Paper des Monats
- ja (1)
Eingeladener Vortrag
- nein (1)
MoS2 is a suitable solid lubricant for environments free of oxygen or water vapor (i.e. vacuum). Humid air degrades film properties due to oxidation accompanied by high wear and increasing coefficients of friction. The present study aims at the further development of sputtered pure MoS2 coatings, extending their applicability to varying environmental conditions by increasing the resistance against humidity. The systematic coating development process is supported by using an experimental Box–Behnken design with variations of the deposition parameters cathode voltage, target/substrate distance, temperature and argon gas pressure. In contrast to common one-factor-at-a-time (OFAT) studies, this approach enables a determination of interactions between deposition process parameters and tribological–mechanical MoS2 film properties. The tribological improvement focuses on a maximization of wear resistance in air and vacuum measured in ball-on-disk experiments. The evaluated mechanical properties are hardness, elastic modulus and residual stresses. These stresses were determined by the substrate curvature method. The study reveals that the residual stress state in the films and the hardness-to-modulus ratio are crucial for their tribological performance in humid air and vacuum environments. After a detailed determination of the relationships between deposition conditions and film properties, some selected microstructural analyses are presented which show that a substantially basal orientation of the lattice has positive effects on wear but also causes anisotropic film properties which result in fissile fracture of the coating if strong shock or point loads occur.
Der Festschmierstoff Molybdändisulfid ist insbesondere für Extremanwendungen ein gerne eingesetzter Werkstoff, problematisch ist jedoch der negative Einfluss von Feuchtigkeit. Bei mittels PVD-Verfahren abgeschiedenen MoS2-Schichten ergibt sich jedoch die Möglichkeit, durch Anpassung der Beschichtungsparameter vorwiegend basal ausgerichtete Schichten herzustellen, die auch an Luft ein verbessertes tribologisches Verhalten zeigen.
Under the auspices of the Protein Analysis Working Group (PAWG) of the Comité Consultatif pour la Quantité de Matière (CCQM) a pilot study, CCQM-P216, was coordinated by the Chinese National Institute of Metrology (NIM), National Research Council of Canada (NRC) and the Bureau International des Poids et Mesures (BIPM). Eleven Metrology Institutes or Designated Institutes and the BIPM participated in the first phase of the pilot study (Part 1). The purpose of this pilot study was to develop measurement capabilities for larger proteins using a recombinant humanized IgG monoclonal antibody against Spike glycoprotein of SARS-CoV-2 (Anti-S IgG mAb) in solution. The first phase of the study was designed to employ established methods that had been previously studies by the CCQM Protein Analysis Working Group, involving the digestion of protein down to the peptide or amino acid level. The global coronavirus pandemic has also led to increased focus on antibody quantitation methods. IgG are among the immunoglobulins produced by the immune system to provide protection against SARS-CoV-2. Anti-SARS-CoV-2 IgG can therefore be detected in samples from affected patients. Antibody tests can show whether a person has been exposed to the SARS-CoV-2, and whether or not they potentially show lasting immunity to the disease. With the constant spread of the virus and the high pressure of re-opening economies, antibody testing plays a critical role in the fight against COVID-19 by helping healthcare professionals to identify individuals who have developed an immune response, either via vaccination or exposure to the virus. Many countries have launched large-scale antibody testing for COVID-19. The development of measurement standards for the antibody detection of SARS-CoV-2 is critically important to deal with the challenges of the COVID-19 pandemic. In this study, the SARS-CoV-2 monoclonal antibody is being used as a model system to build capacity in methods that can be used in antibody quantification. Amino acid reference values with corresponding expanded uncertainty of 36.10 ± 1.55 mg/kg, 38.75 ± 1.45 mg/kg, 18.46 ± 0.78 mg/kg, 16.20 ± 0.67 mg/kg and 30.61 ± 1.30 mg/kg have been established for leucine, valine, phenylalanine, isoleucine and proline, respectively. Agreement between nearly all laboratories was achieved for the amino acid analysis within 2 to 2.5 %, with one participant achieving markedly higher results due to a technical issue found in their procedure; this result was thus excluded from the reference value calculations. The relatively good agreement within a laboratory between different amino acids was not dissimilar to previous results for peptides or small proteins, indicating that factors such as hydrolysis conditions and calibration procedures could be the largest sources of variability. Peptide reference values with corresponding expanded uncertainty of 4.99 ± 0.28 mg/kg and 6.83 ± 0.65 mg/kg have been established for ALPAPIEK and GPSVFPLAPSSK, respectively. Not surprisingly due to prior knowledge from previous studies on peptide quantitation, agreement between laboratories for the peptide-based analysis was slightly poorer at 3 to 5 %, with one laboratory's result excluded for the peptide GPSVFPLAPSSK. Again, this level of agreement was not significantly poorer than that achieved in previous studies with smaller or less complex proteins. To reach the main text of this paper, click on Final Report.
The existence of microbial activity hotspots in temperate regions of Earth is driven by soil heterogeneities, especially the temporal and spatial availability of nutrients. Here we investigate whether microbial activity hotspots also exist in lithic microhabitats in one of the most arid regions of the world, the Atacama Desert in Chile. While previous studies evaluated the total DNA fraction to elucidate the microbial communities, we here for the first time use a DNA separation approach on lithic microhabitats, together with metagenomics and other analysis methods (i.e., ATP, PLFA, and metabolite analysis) to specifically gain insights on the living and potentially active microbial community. Our results show that hypolith colonized rocks are microbial hotspots in the desert environment. In contrast, our data do not support such a conclusion for gypsum crust and salt rock environments, because only limited microbial activity could be observed. The hypolith community is dominated by phototrophs, mostly Cyanobacteria and Chloroflexi, at both study sites. The gypsum crusts are dominated by methylotrophs and heterotrophic phototrophs, mostly Chloroflexi, and the salt rocks (halite nodules) by phototrophic and halotolerant endoliths, mostly Cyanobacteria and Archaea. The major environmental constraints in the organic-poor arid and hyperarid Atacama Desert are water availability and UV irradiation, allowing phototrophs and other extremophiles to play a key role in desert ecology.
Im Vorhaben SNELLIUS wurden in enger Zusammenarbeit der BAM mit den Firmen Accurion und SENTECH Instruments aufbauend auf der Norm DIN 50989-1 „Ellipsometrie - Teil 1: Grundlagen; Ellipsometry – Part 1: Principles“ insgesamt fünf Normenentwürfe erarbeitet, die fünf Modell-basierten Anwendungsfällen der Ellipsometrie entsprechen. Unter Berücksichtigung des neuartigen Modell-basierten Normungskonzepts wurde in den Normenentwürfen erstmals eine GUM- und DIN EN ISO/IEC 17025:2018 konforme Bestimmung bzw. Abschätzung der Messunsicherheit umgesetzt. Dies erforderte neben der textlichen Erstellung auch umfangreiche experimentelle Arbeiten bei den Firmen, Vergleichsversuche und komplementäre Modell- und Datenevaluierungen, da sowohl die verwendete ellipsometrische Hardware (unterschiedliche ellipsometrische Funktionsprinzipien) als auch die ellipsometrische Software (Modell-Randbedingungen, Fitalgorithmus) firmenspezifisch zum Teil sehr unterschiedlich sind. Hierbei mussten in einem Konsensprozess Lösungen gefunden werden, die die beiden deutschen Ellipsometer-Anbieter Accurion (Imaging-Ellipsometrie) und SENTECH Instruments (Mapping Ellipsometrie) gleichermaßen akzeptieren konnten und die zudem einen Transfer auf die Internationale Ebene (ISO Norm) ermöglichen, also vom Grundsatz her auch auf weitere Ellipsometerhersteller wie (J. A. Woollam Co., USA; SEMILAB, Ungarn; HORIBA, Japan) mit wieder anderen ellipsometrischen Funktionsprinzipien, Hard- und Softwarelösungen anwendbar sind. Die weitgehende Unabhängigkeit von ellipsometrischen Funktionsprinzipien, Hard- und Softwarelösungen wurde dadurch erreicht, dass normativ festgelegt wurde, dass die ellipsometrischen Größen PSI und DELTA im Sinne von DIN ENISO/IEC 17025 als Rohdaten fungieren.
The solid lubricant molybdenum disulfide is a well known material for extreme conditions where conventional oil or grease lubrication is not feasible (vacuum, high pressures). However, under reactive environments e.g. high humidity or hydrogen MoS2 is prone to premature failure. By using a PVD process, deposition parameters can be optimized to gain coatings with a more textured structure orienting the basal planes parallel to the Substrate surface, A similar concept has been used by Koch et al. for coatings developed to withstand the extreme operational conditions of the WENDELSTEIN W7-X fusion experiment. Therefore, an improved tribological behavior even under adverse conditions can be achieved.