Filtern
Erscheinungsjahr
- 2018 (3) (entfernen)
Dokumenttyp
- Zeitschriftenartikel (3) (entfernen)
Sprache
- Englisch (3)
Referierte Publikation
- ja (3) (entfernen)
Schlagworte
- Antikörper (3) (entfernen)
Organisationseinheit der BAM
Studies on the development of antibodies for the highly hydrophobic plasticizers DINCH and DEHT
(2018)
Diisononylcyclohexane-1,2-dicarboxylate (DINCH) and di-2-ethylhexyl terephthalate (DEHT), two of the most important substitutes for phthalate plasticizers, are used for a wide range of applications. Consequently, an increasing occurrence in urine and environmental samples is reported. Reliable and fast analytical methods for the quantification of these plasticizers are needed. So far, mainly GC-MS or LC-MS methods are used. We aimed to develop the first antibodies and immunoassays allowing for high-throughput analysis of samples. We designed two DINCH hapten structures and one DEHT hapten structure and employed hapten-protein conjugates for the immunization of rabbits. Sensitive competitive enzyme-linked immunosorbent assays (ELISAs) against each hapten using the produced polyclonal antibodies were established. Yet, binding of DINCH to the respective antibodies was not observed in neither direct nor indirect assay formats, even when using protein conjugates with the heterologous haptens and different carrier proteins in the indirect format. The use of surfactants and solvents in the sample buffer did not result in recognition of the plasticizers. Also, no binding of DEHT in ELISA employing the respective antibodies was detected. We speculate that the production of antibodies against these highly hydrophobic molecules is not possible via our route, however a different hapten design could overcome this obstacle.
In this work we report a novel paper-based analytical device read-out via LED-induced fluorescence detection (FPAD) for the quantification of the emerging pollutant ethinylestradiol (EE2) in river water samples. The PAD was used as a reaction platform for a competitive enzyme immunoassay. For the PAD development, microzones of filter paper, printed by a wax printing method, were modified with amino-functionalized SBA-15 and subsequently, anti-EE2 specific antibodies were covalently immobilized. The determination of EE2 in water was
carried out by adding a fixed concentration of EE2 conjugated with the enzyme horseradish peroxidase (HRP) to samples and standards. Then, the FPAD were added and incubated for 10 min. Finally, the detection was performed by the reaction of 10-acetyl-3,7-dihydroxyphenoxazine (ADHP) whose oxidation is catalyzed by HRP in the presence of H2O2, obtaining the highly fluorescent resorufin (R). Resorufin was detected by LED excitation at 550 nm, observing emission at 585 nm. The EE2 concentration in the samples was inversely proportional to the relative fluorescence obtained from the enzymatic reaction products. The FPAD assay showed a detection Limit (LOD) of 0.05 ng L−1 and coefficients of variation (CV) below 4.5% within-assay and below 6.5% between-assay, respectively. The results obtained show the potential suitability of our FPAD for the selective and sensitive quantification of EE2 in river water samples. In addition, it has the PADs advantages of being disposable, easy to
apply and inexpensive.
The development of fast and cheap highthroughput platforms for the detection of environmental contaminants is of particular importance to understand the human-related impact on the environment. The application of DNA-directed immobilization (DDI) of IgG molecules is
currently limited to the clinical diagnostics scenario, possibly because of the high costs of production of such addressable platforms. We here describe the efficient and specific hybridization of an antibody−oligonucleotide conjugate to a short 12-mer capture probe. The specific antibody used is a monoclonal antibody against caffeine, a stimulant and important anthropogenic marker. With this work, we hope to contribute to broadening the application potential of DDI to environmental markers in order to develop cheaper and more stable high-throughput screening platforms for standard Routine analysis of pollutants in a variety of complex matrices.