Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (18)
- Beitrag zu einem Sammelband (7)
- Beitrag zu einem Tagungsband (2)
- Vortrag (1)
- Sonstiges (1)
Schlagworte
- Plasma polymerization (4)
- Electrospray deposition (3)
- Plasma (3)
- ESCA/XPS (2)
- NEXAFS (2)
- Surface functionalization (2)
- Underwater plasma (2)
- Adhesion promoting interlayers (1)
- Adhesion-promoting layers (1)
- Aggregation (1)
Eingeladener Vortrag
- nein (1)
XPS and NEXAFS spectroscopy were used for the chemical characterization of pulsed plasma-deposited ethylene films before and after exposure to ambient air. The influence of external plasma parameters on the spectroscopic results was investigated. Information on the chemical character of the plasma-polymerized films, such as the regularity of the primary structure, the amount of long-living radicals, and branching or cross-linking or both was derived from this data. Irregularity and radical concentration for post-plasma reactions of the plasma-deposited films increased with the duty cycle or power. A decreased level of monomer fragmentation and, consequently, an increase in regularity is partially concluded from the experimental data when the monomer pressure is increased. The concentration of surface radicals available for post-plasma reactions also increased with monomer pressure. The correlation found between the degree of the post-plasma oxygen incorporation and the variation of the various external parameters agreed with earlier ToF-SSIMS findings.
Introduction of irregularities into plasma polymers by radiative and auto-oxidative processes
(2005)
Dünne, mit einem gepulsten Plasma hergestellte Polymerschichten wurden untersucht. Diese Plasmapolymere sollten eine chemisch besser definierte Struktur haben, weil der Anteil an rein chemisch polymerisiertem Produkt während der Plasma-aus-Zeit steigen sollte, während der Anteil an Schichtbildung, der innerhalb der kurzen Plasmapulse durch Monomerfragmentierung und statistische Polyrekombination erzeugt wird, zurückgedrängt wird. Der Monomerfragmentierungsprozeß ist im kontinuierlich brennenden Plasma (cw-Mode) demgegenüber der Hauptprozeß. Neben der Anwendung der klassischen Element- und Bindungsanalysentechnik XPS (X-ray Photoelectron Spectroscopy) wurden hier die Schichten auch mittels Thermolumineszenz untersucht. Defekte und Strukturanomalitäten in Polymeren sollten mit dieser Methode charakterisiert werden können. Untersuchungsobjekte waren funktionalgruppentragende Plasmapolymerschichten, die biosensorische oder biokompatible Funktionen besitzen oder als Haftvermittler in Metall-Polymercompositen eingesetzt werden.
Translated Abstract
Characterization of Plasmapolymers by Thermoluminescence
Thin plasma polymer films were deposited using the pulsed plasma (pp) mode. These plasma polymers should possess a more chemically regular structure because of the lower monomer fragmentation during the short plasma pulses and the chemical chain propagation during the plasma-less periods than those produced by the conventional continuous-wave (cw) mode. In addition to the use of the classic thin film characterization method XPS the method of thermoluminescence was applied to characterize defects and structural specifics in the polymer films produced by pp or cw-plasma mode. The thermoluminescence method was applied to functional groups-carrying plasma polymer layers, which are used in medical technology for forming biocompatible and bioactive coatings or in metal-polymer composites as adhesion-promoting interlayers.
Chemical properties of plasma-polymerized styrene films can be effectively controlled by the appropriate choice of external plasma parameters, such as duty cycle, power and monomer pressure. Chemical properties here are the regularity of the primary structure, the amount of long living radicals and branching or cross-linking or both in plasma polymerized styrene films, which can be indirectly monitored by X-ray photoelectron spectroscopy (XPS) and near edge X-ray absorption fine structure (NEXAFS) spectroscopy. Principally, XPS and NEXAFS spectra of plasma-polymerized styrene show all the spectroscopic fingerprints characteristic of atactic polystyrene indicating an inherent similarity of the respective primary chemical structures. There is an increase in irregularity and radical concentration for the plasma deposited films with increasing duty cycle or power. With an increase in monomer pressure, a decreased level of monomer fragmentation and, consequently, an increase in regularity must be concluded from the experimental data. The applied power regulates the fragmentation of the monomers as monitored by spectroscopic signals correlated to the aromatic rings. A trend in the extent of the post-plasma oxygen incorporation according to the variation of the various external plasma parameters was deduced, which agrees with earlier ToF-SIMS findings
The production of chemically-defined plasma polymers and the introduction of monotype functional groups onto polymer surfaces are described. One method is to lower the energetic level of low-pressure plasmas. Pressure- and plasma-pulsed plasmas were successfully tested for the production of chemically-defined plasma polymers by increasing the monomer supply during the plasma-off period. Well-defined ultra-thin polymer films with regular structure were deposited from atmospheric plasmas by electrospray techniques. Post-plasma wet-chemical processing was also applied, as were gas/liquid-based aerosols and underwater plasmas.
Thin plasma polymer films were deposited using the pulsed plasma mode. These plasma polymers should possess a more regular structure than those produced by the conventional continuous-wave (cw) mode, because of lower monomer fragmentation caused by the plasma pulses and the chemical chain propagation during the plasmaless (free!) periods. The thermoluminescence method was applied to functional groups carrying plasma polymer layers which are used in medical technology. Examples are formation of biocompatible, biosensoric and bioactive coatings or in metal polymer composites such as adhesion-promoting interlayers.
In addition to the use of the conventional X-ray Photoelectron Spectroscopy for thin film characterization, the new method of thermoluminescence was applied to characterize undesired defects and structural specifics produced in the polymer films by pp or cw plasma mode. The main areas of focus were oxygen-containing groups produced by post-plasma oxygen introduction via auto-oxidation, oxidation of implemented unsaturations and trapped radical sites known as typical irregular structures in plasma polymers.
Polytetrafluoroethylene (PTFE) films have been deposited onto polycarbonate (PC) substrates from the products of PTFE evaporation, activated by a cloud of accelerated electrons. A 40.68 MHz glow discharge was used during the deposition process. The polymer films have been characterised by XPS, FTIR and AFM. The use of the low power plasma during film growth led to the formation of PTFE films with modified structure. Films are amorphous and contain more cross-links, but in general, the structure of their macromolecules is still linear. An increase of RF-power leads to the formation of films with large amount of double bonds and enhanced internal stresses.
Deposition of PTFE on PC without plasma treatment led to the formation of PTFE clusters up to 50 nm in diameter. The RMS roughness of the films, deposited without plasma, was about 4 nm, while the films deposited with plasma treatment had a roughness of 1.5 nm. The use of plasma has an additional effect if a PTFE coating is deposited on the PC substrate with submicrometer-sized steps. Without plasma the steps retain a rectangular shape. Deposited with the RF-discharge the PTFE layers resemble plasma-polymerised films. Under certain conditions the deposited films can fill trenches in the substrate like a wetting liquid, while under other conditions they avoid trenches and grow in between them.
Among new types of plasma processes, the underwater plasma is one of the most attractive methods for functionalization of polymer surfaces. The interesting features of plasma solution system are that the material surfaces to be modified remain in contact with the plasma-moderated solution. The role of plasma-moderated liquids, allows the reach of the reactive species through solution onto the geometrically hindered sites. The UV radiation produced in plasma formation helps in generating additional excited, ionized, and dissociated molecules and species in the reaction solution. An interesting feature of the technique is its flexibility to use a wide variety of additives as or in solution system. This allows us to create a selective or monotype functionalization of material surfaces. Such system was studied for the selective hydroxyl functionalization of polypropylene surface. The oxidation of polymer surfaces and the introduction of O-containing functional groups by underwater plasma was found to exceed concentrations typically achieved in oxygen low-pressure gas discharge plasmas up-to two-folds (maximal 56 O/100 C). The fraction of OH groups among all O-containing moieties amounts from 25 to 40% in comparison to that in the gas plasma of about 10% OH groups. Addition of hydrogen peroxide into this same system increases the fraction of C—O bonds up to 75% (27-OH/100 O). A study was focused to optimize the role of hydrogen peroxide on the efficiency of oxidation and selectivity with chemical derivatization with respect to the formation of mono-sort hydroxyl functionalities, calculated using a chemical derivatization technique.
Substrate-induced self-assembly of donor-acceptor type compounds with terminal thiocarbonyl groups
(2013)
Two types of conjugated thiocarbonyl-terminated compounds have been synthesized and their ability to be adsorbed on surfaces of the different nature, namely, glass, polytetrafluoroethylene (PTFE), and gold has been studied. Different morphology of the films prepared by thermal vacuum evaporation and drop-casting from solutions has been observed depending on the surface used. It has been found that gold surface has a unique property to influence self-assembly of both monolayer and larger aggregates or crystals of the compounds, in contrast to glass and PTFE substrates. It was found that thiocarbonyl group is able to be chemisorbed to the gold surface. However, it was concluded that in spite of the fact that the thiocarbonyl groups are important for the chemical interaction with the gold surface, physical adsorption on the substrate surface, compoundcompound and compound–solvent (when using solution) interactions are of great significance to drive self-assembly of the final film.