Filtern
Erscheinungsjahr
Dokumenttyp
- Beitrag zu einem Tagungsband (33) (entfernen)
Schlagworte
- Friction (7)
- Wear (7)
- Temperature (5)
- Ceramics (3)
- Diamond like carbon (2)
- Fretting (2)
- Reibung (2)
- Schwingungsverschleiß (2)
- Sliding speed (2)
- Stick-slip (2)
- Abrasion (1)
- Abriebverhalten (1)
- Activation energy (1)
- Alcaline earth fluorides (1)
- Alumina (1)
- Apha-alumina (1)
- Bearbeitbarkeit (1)
- Beschichtung (1)
- Binder (1)
- CNx Schichten (1)
- Ceramic (1)
- Colloidal processing (1)
- Composites (1)
- Composits (1)
- Contact geometry crossed cylinders (1)
- DLC (1)
- Dentalkeramik (1)
- Fibers (1)
- Gas pressure sintering (1)
- HIP-Simulation (1)
- Hardness (1)
- Hochleistungskeramik (1)
- Hot steam (1)
- Humidity (1)
- Keramik (1)
- Lubricated sliding (1)
- Magnetronsputtern (1)
- Meßverfahren (1)
- Micro positioning (1)
- Movable cellular automata (MCA) (1)
- NbC (1)
- Ni (1)
- Niobium carbide (1)
- Oscillating sliding (1)
- Partial slip (1)
- Performance test (1)
- Piezoelectric actuator (1)
- Polyetherimide (1)
- Polymer (1)
- Polymers (1)
- Relative humidity (1)
- Silicon carbide (1)
- Silicon nitride (1)
- Simulation (1)
- Solid lubricant (1)
- Steam (1)
- Stick slip (1)
- Surface temperature (1)
- Test bed (1)
- TiC (1)
- Tribologie (1)
- Tribology (1)
- Verschleiß (1)
- Wear infiltration (1)
- Wear resistance (1)
- Zeta Potenzial (1)
- Zirconia (1)
Organisationseinheit der BAM
The interaction of nanosecond laser pulses in the ultraviolet wavelength range and femtosecond laser pulses in the near-infrared region with the direct semiconductor SiC and the composite compound SiC-TiC-TiB2 was investigated in respect to resulting physicochemical processes. Surface analytical techniques, such as XPS, µ-Raman, and EDX were used to identify the chemical changes between untreated and laser-treated areas. Single-pulse irradiation led to material
modifications in the condensed state in most instances. Multi-pulse results differed depending on the pulse duration. In the nanosecond case, melting of the surface and redeposited material (debris) were observed. With femtosecond pulses instead, only negligible melting and few debris could be detected. Additionally, periodic structures (ripples) appeared, with parallel orientation and in most cases two different periodicities for a particular material. Laser ablation of all the studied compound materials exhibited preferential ablation of the lighter component elements. Crystal structure changes of the irradiated surface were observed as a consequence of laser-induced melting and resolidification. An oxidation process interfered with all this processes so that unstoichiometric oxides were formed.
The gelcasting process was used for manufacturing porous ceramic bodies from nano sized powders. 3 different powders with specific surface areas between 12 and 30 m²/g were used. Solid content of the corresponding slurries was dependent on the milling procedure and the use of a suitable dispersant. For bimodal GradeA powder solid content was as high as 58 vol%. For sintering temperatures between 1250 and 1600°C the porosity varied between 45 and 20%, whereas the pore radii varied between 50 and 91nm. The grain size of crystallites in the sintered microstructures was about 1um. The reflection ratio for visible light increased in comparison to a reference sample made from conventional powder from 0.8 to 0.95 in the wavelenght range around 400nm.
Im Vortrag wird neben der apparativen Prüftechnik das allgemeine methodische Vorgehen für Modell-Verschleißuntersuchungen im Bereich des partial slip vorgestellt. Im Detail wird für Dental-Implantat-Werkstoffe eine Rangfolge aufgestellt, die vergleichend die Verschleißresistenz unterschiedlicher Ti-basierter Werkstoffe zeigt. Wird durch die Kaubewegung eine mehrachsige Beanspruchung in die Kontaktflächen der Schraubverbindung eingeleitet, kann durch partial slip im Randbereich dieser Kontaktfläche ein Verschleißprozess initiiert werden, der die Lockerung des Implantats begünstigt. Eine gute Verschleißresistenz verhindert oder schiebt die vorzeitige Lockerung hinaus.
Um das Werkstoffverhalten in Bezug auf eine vorzeitige Lockerung der Implantatkrone bei geschraubten zweiteiligen Implantaten zu charakterisieren, wurden zylindrische Probekörper unter partial slip Fretting-Bedingungen mit Zyklenzahlen bis n = 200 000 beansprucht. Die Frequenz der aufgebrachten Tangentialkraft betrug 2 Hz, um die Kaubewegung zu simulieren.
Die tribologischen Untersuchungen wurden auf einem Eigenbau-Tribometer mit der Kontaktgeometrie „gekreuzte Zylinder“ durchgeführt. Die zylindrischen Proben wurden aus den Werkstoffen Titan Grade 4 und der Ti-Legierung Ti6AI4V gefertigt. Ein Teil dieser Ti-basierten Proben wurde oberflächengehärtet. Die bisher erzielten Ergebnisse zeigen, dass die oberflächenbehandelten Proben dazu neigen, unter der Belastung die Kontaktfläche zu vergrößern. Dies deutet auf einen Effekt bekannt als „junction growth“ und damit auf eine erhöhte Versetzungsbeweglichkeit der randschichtgehärteten Proben hin. Einen Einfluss der Zwischenstoffe konnte nicht nachgewiesen werden.