Filtern
Erscheinungsjahr
Dokumenttyp
Schlagworte
- Brominated flame retardant (4)
- Chiral separation (3)
- Extraction (3)
- Gas chromatography (3)
- HPLC-MS/MS (3)
- Analysis (2)
- Breath (2)
- Diastereomers (2)
- Flame retardant (2)
- GC-MS (2)
Organisationseinheit der BAM
A Proof of Concept: Are Detection Dogs a Useful Tool to Verify Potential Biomarkers for Lung Cancer?
(2018)
Early and reliable diagnostic test is essential for effective therapy of lung cancer. Volatile organic compounds that are characteristic for cancer could serve as valuable biomarkers in cancer diagnosis. Both trace analytical and detection dog approaches give some evidence for the existence of such biomarkers. In this proof of concept, study dogs and trace analysis were implemented in combination to gain more information concerning cancer biomarkers. Two dogs were trained to distinguish between absorbed breath samples of lung cancer patients and healthy persons and succeeded with correct identification of patients with 9/9 and 8/9 and correct negative indications from of 8/10 and 4/10 samples from healthy individuals. A recent observational study found that breath samples from lung cancer patients showed an increase in 1-butanol, 2-butanone, 2-pentanone, and hexanal. Synthetic air samples were therefore fortified with these compounds and adsorbed to a fleece. Tested against breath samples from healthy probands, on presentation to the dogs these synthetic samples provoked an indication in three out of four samples. We were able to demonstrate that a combination of the natural nose of a dog and a trace analytic technique can be a valuable concept in the search for cancer biomarkers.
Fuel contamination of soils display complex and variable hydrocarbon mixtures with different volatility and toxicity characteristics. A recently suggested headspace procedure for the structure-based quantification of volatile hydrocarbons is evaluated regarding repeatability, reproducibility, and practical robustness. Three aliphatic and three aromatic fractions covering the boiling range between 69 and 216°C were defined as summation parameters by their respective equivalent carbon number ranges. A standard mixture of 35 aliphatic and aromatic hydrocarbons was used for calibration on basis of selected mass fragments specific for the aliphatics and aromatics, respectively. Two standard soils were fortified with the standard mixture or different fuels, respectively, and submitted to the analytical procedure. Limit of detection (LOD) and limit of quantification (LOQ) were for all fractions lower than 0.1 and 0.3 mg/kg, respectively. Analyte recovery was linear up to between 20 and 110 mg hydrocarbons/kg soil depending on the fraction. Hydrocarbon recovery ranged between 80% and 110% depending on the fraction and the repeatability was typically better than 10%. Finally, the impact of extraction solvent variation, column solid-phase polarity, and alternative summation of fractions were investigated. The procedure was applied to liner samples taken from a site contaminated with aviation fuel and its practicability is discussed.
Odor Perception by Dogs: Evaluating Two Training Approaches for Odor Learning of Sniffer Dogs
(2017)
In this study, a standardized experimental set-up with various combinations of herbs as odor sources was designed. Two training approaches for sniffer dogs were compared; first, Training with a pure reference odor, and second, training with a variety of odor mixtures with the target odor as a common denominator. The ability of the dogs to identify the target odor in a new context was tested. Six different herbs (basil, St. John’s wort, dandelion, marjoram, parsley, ribwort) were chosen to produce reference materials in various mixtures with (positive) and without (negative)chamomile as the target odor source. The dogs were trained to show 1 of 2 different behaviors, 1 for the positive, and 1 for the negative sample as a yes/no task. Tests were double blind with one sample presented at a time. In both training approaches, dogs were able to detect chamomile as the target odor in any presented mixture with an average sensitivity of 72% and a specificity of 84%. Dogs trained with odor mixture containing the target odor had more correct indications in the transfer task.
The design and operation of an observational study on the profiles of volatile organic compounds (VOC) in the breath of 37 lung cancer patients and 23 healthy controls of similar age is outlined. The necessity to quantify each VOC considered as potential disease marker on basis of individual calibration is elaborated and the quality control measures required to maintain reproducibility in breath sampling and subsequent instrumental trace VOC analysis using SPME-GC-MS over a study period of 14 months are described. 24 VOC were quantified on basis of their previously suggested potential as cancer markers. The breath concentration levels of aromatic compounds was expectedly increased in smokers while lung cancer patients displayed significantly increased levels of oxygenated VOC such as aldehydes, 2-butanone and 1-butanol. Though sets of selected oxygenated VOC displayed sensitivities and specificities between 80 and 90% using linear discriminant analysis with leave-one-out cross validation the effective selectivity of the breath VOC approach with regard to cancer detection is clearly limited. Results were discussed against the background of the literature on volatile cancer marker investigations and the prospects to link increased VOC levels in patients’ breath with approaches to employ sniffer dogs. Experiences from this study and the literature suggest that the current state of breath VOC based discrimination between cancer patients and healthy controls is hardly improvable. Observational studies tend to observe significant differences mostly in levels of certain oxygenated VOC but without resolution required for practical application. Any step towards practicable exploitation of VOC profile differences for illness detection would have to solve current restrictions set by the low and variable VOC concentrations. Further challenges are the technical complexity of studies involving breath sampling and possibly the limited capability of current analytical procedures to detect instable marker candidates.
Wie viele Forschergruppen, haben auch wir uns das langfristige Ziel gesetzt, einen Beitrag bei der Beantwortung der Frage zu leisten, was Hunde riechen, wenn sie Krebs erschnüffeln.
Dabei sollen die Hunde nicht nur anzeigen, ob eine Atemluftprobe positiv oder negativ ist, sondern sie sollen auch aktiv eingebunden werden in den systematischen Suchprozess nach detektierbaren Biomarkern. So ist geplant, dass mittels eines präparativen Fraktionssammlers definierte Schnitte des Gaschromatogramms einzeln oder in möglichen Kombinationen auf das Adsorbervlies gebracht werden, um im Hundetraining eingesetzt zu werden. In analoger Weise könnte auch mit spezifischen Kandidatensubstanzen verfahren werden.
In vitro cultured lung cancer cells are not suitable for animal-based breath biomarker detection
(2015)
In vitro cultured lung cancer cell lines were investigated regarding the possible identification of volatile organic compounds as potential biomarkers. Gas samples from the headspace of pure culture medium and from the cultures of human lung adenocarcinoma cell lines A549 and Lu7466 were exposed to polypropylene fleece in order to absorb odour components. Sniffer dogs were trained with loaded fleeces of both cell lines, and honey bees were trained with fleeces exposed to A549. Afterwards, their ability to distinguish between cell-free culture medium odour and lung cancer cell odour was tested. Neither bees nor dogs were able to discriminate between odours from the cancer cell cultures and the pure culture medium. Solid phase micro extraction followed by gas chromatography with mass selective detection produced profiles of volatiles from the headspace offered to the animals. The profiles from the cell lines were largely similar; distinct differences were based on the decrease of volatile culture medium components due to the cells' metabolic activity. In summary, cultured lung cancer cell lines do not produce any biomarkers recognizable by animals or gas chromatographic analysis.
This article describes a simple and quick in silico method for the prediction of cytochrome P450 (CYP)-mediated hydroxylation of drug-like compounds. Testosterone and progesterone, two known substrates of CYP3A4, are used to test the method. Further, we apply the procedure to predict sites of hydroxylation of isomers of the flame retardant hexabromocyclododecane by CYP3A4. Within the method, the compound is rotated in the binding pocket of the cytochrome, so that each hydrogen under consideration is placed near the active centre. Afterwards, short molecular dynamics simulations are provided for each step of the rotation. All steps of the simulation are compared concerning the distances between the hydrogens and the active centre and the corresponding energies. The computational results correlate well with experimental results.
Two different hair reference materials, one produced from authentic hair displaying an ethyl glucuronide (EtG) content of about 25 pg/mg and one obtained by fortification of blank hair to an EtG level of 85 pg/mg were submitted to accelerated aging between 4 degrees C and 60 degrees C for periods between one and 24 months. Subsequently, the EtG content was determined in the aged samples and untreated reference samples stored at -22 degrees C under repeatability conditions following the so-called isochronous approach. The EtG content remained stable even at 40 degrees C for 24 months and at 60 degrees C over six months. This is in contrast to many organic analytes contained in trace concentrations in diverse matrices. A slight but significant increase of the recovered EtG in case of authentic hair samples having been exposed for 24 months between 4 degrees C and 60 degrees C may be due to a temperature-driven process that allows increased recoveries of the physiologically embedded EtG.
Als Folge der industriellen Produktion und der vielfältigen industriellen Nutzung von organischen Lösungsmitteln sind eine Vielzahl von Edukten, Zwischen- und Endprodukten in die Umwelt eingetragen worden und führen zu massiven Verunreinigungen des Bodens und des Grundwassers. Die Untersuchung und Sanierung des Grundwassers stellt einen aktuellen Schwerpunkt in der Altlastenbearbeitung dar. Vielfach werden klassische pump & treat-Verfahren zur Grundwassersanierung verwendet. Diese aktiven Sicherungs- und Sanierungsmaßnahmen werden jedoch unter dem Gesichtspunkt der Verhältnismäßigkeit häufig als ineffizient eingeschätzt. Als Alternative sollen die natürlichen Abbauprozesse im Grundwasserleiter genutzt oder gezielt verstärkt werden, um auf diesem Weg eine in-situ-Sanierung des Grundwasserleiters zu erreichen. In den letzten Jahren haben sich verschiedene Sanierungsverfahren etabliert, bei denen durch die Zugabe von Hilfsstoffen die mikrobiologische Aktivität des Aquifers erhöht wird bzw. Stoffe zugeführt werden, die mit den Schadstoffen reagieren (in-situ chemische Oxidation bzw. Reduktion, ISCO). An ausgewählten Standorten ist auch die aktive Sanierung (pump & treat, on-site- Sanierung) mit biologischem Schadstoffabbau (Bio-Filter) kombiniert worden. Um den Sanierungsverlauf zu verfolgen und zu optimieren, ist die Beprobung von Grundwasser aus dem Grundwasserleiter oder aus laufenden Anlagen erforderlich. In Fällen der gesteigerten mikrobiologischen Aktivität des Grundwassers treten gehäuft Probleme bei der Stabilisierung der Wasserproben auf. Die forcierten Abbauprozesse der Schadstoffe gehen nach der Probenahme in der Probenflasche weiter, bis die Energiebasis der Mikrobiologie aufgebraucht ist. Durch eine geringe Temperaturerhöhung beschleunigen sich diese Prozesse zusätzlich. In der Folge können die Schadstoffgehalte teilweise innerhalb weniger Stunden stark reduziert werden. Im Analysenlabor wird dann ein Schadstoffgehalt nachgewiesen, der nicht mehr die Verhältnisse im Aquifer bzw. im Ablauf der Reinigungsstufen widerspiegelt. Eine Einschätzung des Sanierungsfortschritts oder der Reinigungsleistung ist unter diesen Bedingungen stark fehlerbehaftet und kann zu groben Fehlinterpretationen führen. Grundwasserproben, die einem Aquifer mit hoher natürlicher oder initiierter mikrobiologischer Abbauaktivität entstammen, müssen daher zusätzlich stabilisiert werden, um den Ist-Zustand zum Zeitpunkt der Probenahme zu erfassen. Die Konservierung von Wasserproben bei der Probenahme von Grundwasser ist in der Normung umfangreich beschrieben: Die EN ISO 5667-3 von 2004 ist im Normausschuss (NA 119-01-03-01-01) überarbeitet und 2012 als Norm verabschiedet worden (EN ISO 5667-3, 03.12, deutsche Fassung DIN EN ISO 5667-3, 03-2013) [1], In Einzelfällen hat sie sich nicht als ausreichend erwiesen, um die Stabilität der organischen Schadstoffe in den oben beschriebenen Wasserproben zu gewährleisten.
A combination of simultaneous milling and extraction known as micropulverized extraction was developed for the quantification of the alcohol marker ethyl glucuronide (EtG) in hair samples using a homogeneous reference material and a mixer mill. Best extraction results from 50 mg of hair were obtained with 2-mL plastic tubes containing two steel balls (Ø = 5 mm), 0.5 mL of water and with an oscillating frequency of 30 s-1 over a period of 30 min. EtG was quantified employing a validated GC-MS procedure involving derivatization with pentafluoropropionic acid anhydride. This micropulverization procedure was compared with dry milling followed by separate aqueous extraction and with aqueous extraction after manual cutting to millimeter-size snippets. Micropulverization yielded 28.0±1.70 pg/mg and was seen to be superior to manually cutting (23.0±0.83 pg/mg) and equivalent to dry grinding (27.7±1.71 pg/mg) with regard to completeness of EtG extraction. The option to process up to 20 samples simultaneously makes micropulverization especially valuable for the high throughput of urgent samples.