Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (86)
- Posterpräsentation (23)
- Vortrag (19)
- Beitrag zu einem Tagungsband (18)
- Sonstiges (8)
- Beitrag zu einem Sammelband (3)
- Forschungsbericht (3)
Schlagworte
- Boden (12)
- Eignungsprüfung (9)
- Interlaboratory comparison (9)
- MKW (9)
- Soil (9)
- Proficiency testing (8)
- Gesamtcyanid (7)
- PAK (7)
- Spurenelemente (7)
- PAH (6)
Organisationseinheit der BAM
- 1 Analytische Chemie; Referenzmaterialien (23)
- 1.7 Organische Spuren- und Lebensmittelanalytik (23)
- 6 Materialchemie (6)
- 4 Material und Umwelt (5)
- 6.6 Physik und chemische Analytik der Polymere (4)
- 5 Werkstofftechnik (3)
- 6.3 Strukturanalytik (3)
- 1.4 Prozessanalytik (2)
- 1.6 Anorganische Referenzmaterialien (2)
- 4.0 Abteilungsleitung und andere (2)
- 4.3 Schadstofftransfer und Umwelttechnologien (2)
- 5.3 Polymere Verbundwerkstoffe (2)
- 1.1 Anorganische Spurenanalytik (1)
- 1.2 Biophotonik (1)
- 1.8 Umweltanalytik (1)
- 4.1 Biologische Materialschädigung und Referenzorganismen (1)
- 4.2 Material-Mikrobiom Wechselwirkungen (1)
- 4.4 Thermochemische Reststoffbehandlung und Wertstoffrückgewinnung (1)
- 5.6 Glas (1)
- 7 Bauwerkssicherheit (1)
- 7.5 Technische Eigenschaften von Polymerwerkstoffen (1)
- VP Vizepräsident (1)
- VP.1 eScience (1)
Paper des Monats
- ja (1)
Eingeladener Vortrag
- nein (19)
Gegenstand der vorzustellenden Arbeiten ist die Prüfung der Umwelt-beständigkeit und -verträglichkeit von Materialien und Produkten hinsichtlich der Emission von potenziellen Schadstoffen in die Umwelt. Hierzu werden chemisch-physikalische Einflüsse (Bewitterung) und mikrobielle Beanspruchungen an Modellmaterialien evaluiert. So werden die Freisetzungsraten von Schadstoffen in Abhängigkeit der Beanspruchung beschrieben. Als Modellmaterialien kommen die Polymere Polystyrol (PS) und Polypropylen (PP) zum Einsatz. Synergistische Effekte der Bewitterungsparameter und der mikrobiologischen Beanspruchung sollen dabei ebenso betrachtet werden, wie die gezielte Alterung. Auch findet eine Beschreibung des Verhaltens der ausgetragenen Schadstoffe in den Umweltkompartimenten Boden oder Wasser statt. Hier sind mit Hilfe der zu entwickelnden Screening- und non-Target-Analyseverfahren die Transformation und der Metabolismus durch Mikroorganismen zu beschreiben. Aus den Ergebnissen sollen Korrelationen zwischen den künstlichen Alterungsverfahren und realen Szenarien abgeleitet werden.
Wie viele Forschergruppen, haben auch wir uns das langfristige Ziel gesetzt, einen Beitrag bei der Beantwortung der Frage zu leisten, was Hunde riechen, wenn sie Krebs erschnüffeln.
Dabei sollen die Hunde nicht nur anzeigen, ob eine Atemluftprobe positiv oder negativ ist, sondern sie sollen auch aktiv eingebunden werden in den systematischen Suchprozess nach detektierbaren Biomarkern. So ist geplant, dass mittels eines präparativen Fraktionssammlers definierte Schnitte des Gaschromatogramms einzeln oder in möglichen Kombinationen auf das Adsorbervlies gebracht werden, um im Hundetraining eingesetzt zu werden. In analoger Weise könnte auch mit spezifischen Kandidatensubstanzen verfahren werden.
1,2,5,6,9,10-hexabromocyclododecane (HBCD), a widely used flame retardant, is an ubiquitous contaminant in
the environment. Still, only little is known about the distribution and behavior in the environment such as
bioaccumulation or biotransformation of HBCD stereoisomers. In order to investigate enrichment and possible
bioisomerization of HBCD stereoisomers, Mirror Carps were exposed to pure (+)- and (-)-γ-HBCD, randomly
sampled after a predefined specific period and subjected to enantiomer-specific determination of α-, β-, and γ-
HBCD. No evidence for the isomerization of HBCD stereoisomers was observed in Mirror Carp fillets.
The key comparison CCQM-K102: Polybrominated diphenyl ethers in sediment was coordinated by the JRC, Directorate F - Health, Consumers & Reference Materials, Geel (Belgium) under the auspices of the Organic Analysis Working Group (OAWG) of the Comité Consultatif pour la Quantité de Matière (CCQM). Thirteen National Metrology institutes or Designated Institutes and the JRC participated. Participants were requested to report the mass fraction (on a dry mass basis) of BDE 47, 99 and 153 in the freshwater sediment study material. The sediment originated from a river in Belgium and contained PBDEs (and other pollutants) at levels commonly found in environmental samples. The comparison was designed to demonstrate participants' capability of analysing non-polar organic molecules in abiotic dried matrices (approximate range of molecular weights: 100 to 800 g/mol, polarity corresponding to pKow < −2, range of mass fraction: 1–1000 μg/kg). All participants (except one using ultrasonic extraction) applied Pressurised Liquid Extraction or Soxhlet, while the instrumental analysis was performed with GC-MS/MS, GC-MS or GC-HRMS. Isotope Dilution Mass Spectrometry approach was used for quantification (except in one case). The assigned Key Comparison Reference Values (KCRVs) were the medians of thirteen results for BDE 47 and eleven results for BDE 99 and 153, respectively. BDE 47 was assigned a KCRV of 15.60 μg/kg with a combined standard uncertainty of 0.41 μg/kg, BDE 99 was assigned a KCRV of 33.69 μg/kg with a combined standard uncertainty of 0.81 μg/kg and BDE 153 was assigned a KCRV of 6.28 μg/kg with a combined standard uncertainty of 0.28 μg/kg. The k-factor for the estimation of the expanded uncertainty of the KCRVs was chosen as k = 2.
The resource-saving utilisation of recovered
waste wood is a matter of growing concern. In several
European countries, this utilisation is governed by regulations
and is dependent on the contents of certain trace
elements and organic compounds. Thus, for decisionmaking
with respect to waste wood management (recycling
or combustion), reliable analytical data are needed and, due
to their great economic and environmental impact, must be
assured by appropriate quality control. To support the
improvement in quality assurance in waste wood analysis,
for the first time, a wood reference material was certified
for its mass fractions of arsenic, cadmium, chromium,
copper, lead, mercury, and pentachlorophenol (PCP).
These analytes were selected because they represent typical
constituents of wood preservatives most widely used in the
past. Material preparation and testing of homogeneity and
stability were carried out by BAM Federal Institute for
Materials Research and Testing. The certification measurements
were performed involving selected laboratories
with documented expertise in the field of waste wood
analysis. The certified values and their corresponding
uncertainties were assigned in full compliance with the
requirements of ISO Guide 35. The certified mass fractions
and their expanded uncertainties (k/i> = 2) are as follows:
(3.1 ± 0.5) mg/kg for As, (3.02 ± 0.24) mg/kg for Cd,
(36.4 ± 2.6) mg/kg for Cr, (22.9 ± 1.7) mg/kg for Cu,
(0.60 ± 0.14) mg/kg for Hg, (39 ± 4) mg/kg for Pb, and
(7.9 ± 0.6) mg/kg for PCP. The certified material is
available as European Reference Material ERM®-CD100.
Certified reference materials for organic contaminants in sewage sludge - a feasibility study
(2008)
As an answer to the re-evaluation of the European sludge directive, two novel reference materials for organic components in municipal sludge have been produced and test certified for AOX (absorbable organic halogens), PAH (polycyclic aromatic hydrocarbons), NPE (nonylphenol and nonylphenolethoxylates), DEHP (di(2-ethylhexyl)phthalate), bisphenol A, and BFR (brominated flame retardants). The materials were prepared from raw sludge without spiking or mixing of different sludges. The study demonstrated that the technique for the preparation of a suitable reference material, sufficiently homogenous and stable, and with concentration levels that answer the needs of the laboratories and the relevant authorities, can now be presented in detail. The results, furthermore, show there is a need for method validation and standardisation of the measurements of NPEs and certain BFR congeners, and that the development of the laboratory structure in Europe, with fewer and more specialised laboratories, might become a major obstacle when trying to find a sufficient number of laboratories being appropriately proficient for this kind of study in the future.
In this paper, we investigate the interconversion processes of the major flame retardant - 1,2,5,6,9,10-hexabromocyclododecane (HBCD) - by the means of statistical thermodynamics based on classical force-fields. Three ideas will be presented. First, the application of classical hybrid Monte-Carlo simulations for quantum mechanical processes will be justified. Second, the problem of insufficient convergence properties of hybrid Monte-Carlo methods for the generation of low temperature canonical ensembles will be solved by an interpolation approach. Furthermore, it will be shown how free energy differences can be used for a rate matrix computation. The results of our numerical simulations will be compared to experimental results.
In recent years, an increasing trend towards investigating and monitoring the contamination of the environment by microplastics (MP) (plastic pieces < 5 mm) has been observed worldwide. Nonetheless, a reliable methodology that would facilitate and automate the monitoring of MP is still lacking. With the goal of selecting practical and standardized methods, and considering the challenges in microplastics detection, we present here a critical evaluation of two vibrational spectroscopies, Raman and Fourier transform infrared (FTIR) spectroscopy, and two extraction methods: thermal extraction desorption gas chromatography mass spectrometry (TED-GC-MS) and liquid extraction with subsequent size exclusion chromatography (SEC) using a soil with known contents of PE, PP, PS and PET as reference material. The obtained results were compared in terms of measurement time, technique handling, detection limits and requirements for sample preparation. The results showed that in designing and selecting the right methodology, the scientific question that determines what needs to be understood is significant, and should be considered carefully prior to analysis. Depending on whether the object of interest is quantification of the MP particles in the sample, or merely a quick estimate of sample contamination with plastics, the appropriate method must be selected. To obtain overall information about MP in environmental samples, the combination of several parallel approaches should be considered.
Three chromatographic procedures were investigated regarding their potential for the quantification of aniline and 19 of its methylated and chlorinated derivatives in groundwater. These methods were based on liquid-liquid-extraction in combination with gas chromatography and single quadrupole mass spectrometry (GC/MS) according to German standard DIN 38407-16:1999 and its extension using tandem mass spectrometry (GC/MS-MS), both following liquid-liquid extraction, and as third alternative the direct injection of the water sample into a liquid chromatograph coupled to tandem mass spectrometry (LC/MS-MS). Results were compared using fortified water and real-world contaminated groundwater used in an interlaboratory comparison. It could be shown that GC/MS and GC/MS-MS yielded results deviating less than 10% from each other while all three procedure displayed quantification results deviating less than 15% from the intercomparison reference values in case of each analyte in the concentration range between 1 and 45 µg L-1. Though GC/MS-MS displays a ten-fold higher sensitivity than single quadrupole GC/MS, the precision of both methods in the concentration range was similar. LC/MS-MS has the advantage of no further sample preparation due to the direct injection and leads for methylanilines and meta-, para- substituted chloroanilines to results sufficiently equivalent to the standardised GC/MS method. However, LC/MS-MS is not suitable for ortho-chloroaniline derivates due to significantly lower ion yields than meta- and para-substituted chloroanilines.
The design and operation of an observational study on the profiles of volatile organic compounds (VOC) in the breath of 37 lung cancer patients and 23 healthy controls of similar age is outlined. The necessity to quantify each VOC considered as potential disease marker on basis of individual calibration is elaborated and the quality control measures required to maintain reproducibility in breath sampling and subsequent instrumental trace VOC analysis using SPME-GC-MS over a study period of 14 months are described. 24 VOC were quantified on basis of their previously suggested potential as cancer markers. The breath concentration levels of aromatic compounds was expectedly increased in smokers while lung cancer patients displayed significantly increased levels of oxygenated VOC such as aldehydes, 2-butanone and 1-butanol. Though sets of selected oxygenated VOC displayed sensitivities and specificities between 80 and 90% using linear discriminant analysis with leave-one-out cross validation the effective selectivity of the breath VOC approach with regard to cancer detection is clearly limited. Results were discussed against the background of the literature on volatile cancer marker investigations and the prospects to link increased VOC levels in patients’ breath with approaches to employ sniffer dogs. Experiences from this study and the literature suggest that the current state of breath VOC based discrimination between cancer patients and healthy controls is hardly improvable. Observational studies tend to observe significant differences mostly in levels of certain oxygenated VOC but without resolution required for practical application. Any step towards practicable exploitation of VOC profile differences for illness detection would have to solve current restrictions set by the low and variable VOC concentrations. Further challenges are the technical complexity of studies involving breath sampling and possibly the limited capability of current analytical procedures to detect instable marker candidates.
Als Folge der industriellen Produktion und der vielfältigen industriellen Nutzung von organischen Lösungsmitteln sind eine Vielzahl von Edukten, Zwischen- und Endprodukten in die Umwelt eingetragen worden und führen zu massiven Verunreinigungen des Bodens und des Grundwassers. Die Untersuchung und Sanierung des Grundwassers stellt einen aktuellen Schwerpunkt in der Altlastenbearbeitung dar. Vielfach werden klassische pump & treat-Verfahren zur Grundwassersanierung verwendet. Diese aktiven Sicherungs- und Sanierungsmaßnahmen werden jedoch unter dem Gesichtspunkt der Verhältnismäßigkeit häufig als ineffizient eingeschätzt. Als Alternative sollen die natürlichen Abbauprozesse im Grundwasserleiter genutzt oder gezielt verstärkt werden, um auf diesem Weg eine in-situ-Sanierung des Grundwasserleiters zu erreichen. In den letzten Jahren haben sich verschiedene Sanierungsverfahren etabliert, bei denen durch die Zugabe von Hilfsstoffen die mikrobiologische Aktivität des Aquifers erhöht wird bzw. Stoffe zugeführt werden, die mit den Schadstoffen reagieren (in-situ chemische Oxidation bzw. Reduktion, ISCO). An ausgewählten Standorten ist auch die aktive Sanierung (pump & treat, on-site- Sanierung) mit biologischem Schadstoffabbau (Bio-Filter) kombiniert worden. Um den Sanierungsverlauf zu verfolgen und zu optimieren, ist die Beprobung von Grundwasser aus dem Grundwasserleiter oder aus laufenden Anlagen erforderlich. In Fällen der gesteigerten mikrobiologischen Aktivität des Grundwassers treten gehäuft Probleme bei der Stabilisierung der Wasserproben auf. Die forcierten Abbauprozesse der Schadstoffe gehen nach der Probenahme in der Probenflasche weiter, bis die Energiebasis der Mikrobiologie aufgebraucht ist. Durch eine geringe Temperaturerhöhung beschleunigen sich diese Prozesse zusätzlich. In der Folge können die Schadstoffgehalte teilweise innerhalb weniger Stunden stark reduziert werden. Im Analysenlabor wird dann ein Schadstoffgehalt nachgewiesen, der nicht mehr die Verhältnisse im Aquifer bzw. im Ablauf der Reinigungsstufen widerspiegelt. Eine Einschätzung des Sanierungsfortschritts oder der Reinigungsleistung ist unter diesen Bedingungen stark fehlerbehaftet und kann zu groben Fehlinterpretationen führen. Grundwasserproben, die einem Aquifer mit hoher natürlicher oder initiierter mikrobiologischer Abbauaktivität entstammen, müssen daher zusätzlich stabilisiert werden, um den Ist-Zustand zum Zeitpunkt der Probenahme zu erfassen. Die Konservierung von Wasserproben bei der Probenahme von Grundwasser ist in der Normung umfangreich beschrieben: Die EN ISO 5667-3 von 2004 ist im Normausschuss (NA 119-01-03-01-01) überarbeitet und 2012 als Norm verabschiedet worden (EN ISO 5667-3, 03.12, deutsche Fassung DIN EN ISO 5667-3, 03-2013) [1], In Einzelfällen hat sie sich nicht als ausreichend erwiesen, um die Stabilität der organischen Schadstoffe in den oben beschriebenen Wasserproben zu gewährleisten.