Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (87) (entfernen)
Schlagworte
- Interlaboratory comparison (9)
- Gas chromatography (6)
- Extraction (5)
- Analysis (4)
- Boden (4)
- Brominated flame retardant (4)
- Groundwater (4)
- HPLC-MS/MS (4)
- Breath (3)
- Chiral separation (3)
- Mass spectrometry (3)
- Microplastics (3)
- Proficiency testing (3)
- Ringversuch (3)
- VOC (3)
- Volatile organic compounds (3)
- Volatilome (3)
- A549 (2)
- Alcohol marker (2)
- Aniline (2)
- Certification (2)
- Certified reference materials (2)
- Chloroanilines (2)
- Crystal structure (2)
- Degradation (2)
- Diastereomers (2)
- Ethyl glucuronide (2)
- Flame retardant (2)
- Food (2)
- Fortification (2)
- GC-FID (2)
- GC-MS (2)
- HBCD (2)
- Hydroxylation (2)
- Kinetics (2)
- Liquid chromatography (2)
- Long term stability (2)
- Lung cancer (2)
- Methylanilines (2)
- Micropulverization (2)
- Mikroplastik (2)
- Molecular dynamics (2)
- Organic pollutants (2)
- Phenols (2)
- Reference materials (2)
- Sampling (2)
- Sewage sludge (2)
- Soil (2)
- Solid phase microextraction (2)
- Summation parameter (2)
- AOX (1)
- APCI (1)
- Abfall (1)
- Absolute configuration (1)
- Abwasser (1)
- Acrylamid (1)
- Active sampling (1)
- Adsorption (1)
- Akkreditierung (1)
- Analysis and identification (1)
- Analytik (1)
- Anomalous dispersion (1)
- Anomeric configuration (1)
- Antioxidant properties (1)
- Arrhenius model (1)
- Artificial weathering (1)
- BFR (1)
- BPA (1)
- BTEX (1)
- Bacteria (1)
- Benzenes (1)
- Beta-cyclodextrin (1)
- Binding affinity (1)
- Bio test battery (1)
- Bioaccumulation (1)
- Biochar (1)
- Biofouling (1)
- Bioisomerization (1)
- Biomarkers (1)
- Bleaching (1)
- Bromierte Falmmschutzmittel (1)
- Brominated flame retardants (1)
- CEC-L-103 (1)
- CRM (1)
- Calibration (1)
- Calix[4]resorcinarenes (1)
- Cancer (1)
- Chemical analysis (1)
- Chemometrics (1)
- Collaborative trial (1)
- Combustion (1)
- Conformational chirality (1)
- Contaminated site (1)
- Contamination (1)
- Crosslinking (1)
- Crystal structures (1)
- Cysteic acid (1)
- Cytochrom (1)
- Cytochrome P450 (1)
- Cytochromes (1)
- D-Glucuronic acid derivates (1)
- DEHP (1)
- DFA (1)
- Data-to-parameter ratio = 20.4 (1)
- Degradation of refrigerants (1)
- Derivatisation (1)
- Derivatisierung (1)
- Derivatization (1)
- Detection dog (1)
- Diffusionsprobe (1)
- Dithiocarbamate (1)
- Dithiopercarbamate (1)
- ERM (1)
- Einfluß (1)
- Eingnugsprüfung (1)
- Elution order (1)
- Enantiomer fraction (1)
- Enantiomer-specific bioaccumulation (1)
- Enantiomer-specific determination (1)
- Enantiomeric fraction (1)
- Enantiomers (1)
- Equivalence (1)
- Equivalent carbon number (1)
- European Reference Material (1)
- European reference material (1)
- European waste list (1)
- External quality management (1)
- FTIR imaging (1)
- Fish feeding experiment (1)
- Flame ionization detection (1)
- Flame retardants (1)
- Fluoroacetic acid (1)
- Fuel (1)
- Fungi (1)
- Furfurals (1)
- GC (1)
- GC-AED (1)
- GC/MS (1)
- GC/MS-MS (1)
- GCMS (1)
- Gaschromatographie (1)
- Gasoline (1)
- Ground water (1)
- Groundwater monitoring (1)
- Grundwasser (1)
- HBCDs (1)
- HPLC (1)
- HPLC-DAD (1)
- HPLC-ESI-MS/MS (1)
- HPLCMS/MS (1)
- Hair (1)
- Hair testing (1)
- Hexabromcyclododecan (1)
- High resolution NMR (1)
- High-throughput analysis (1)
- Homogeneity (1)
- Honey bees (1)
- Hydrocarbons (1)
- Hydrochar (1)
- Hydrogen bonded molecular capsule (1)
- ICP-MS (1)
- ICP-OES (1)
- IR spectrometry (1)
- Indoor air (1)
- Intercomparison (1)
- Interlaboratory study (1)
- International intercomparison (1)
- Ion chromatography (1)
- Isoleucin (1)
- Isomerisation (1)
- Kalibrierstand (1)
- Kompetenzbewertung (1)
- LC-MS (1)
- LC/MS-MS (1)
- LHKW (1)
- Lung cancer cell culture (1)
- MKW (1)
- MOSH/MOAH (1)
- Marker (1)
- Markov process (1)
- Measurement uncertainty (1)
- Metabolism of HBCD (1)
- Metaboliten (1)
- Metal-organic complexes (1)
- Methane (1)
- Method development (1)
- Method validation (1)
- Metrology (1)
- Micropulverized extraction (1)
- Mineral oil (1)
- Mineral oil hydrocarobons (1)
- Mineralölkohlenwasserstoff (1)
- Mineralölkohlenwasserstoffe (1)
- Minor isomers (1)
- Moisture (1)
- Molecular simulation (1)
- Municipal sludge (1)
- NPE (1)
- Nation metrology institutes (1)
- Near Infrared Spectroscopy (1)
- Network (1)
- Odour discrimination task (1)
- Optical rotation (1)
- Organohalogen compounds (1)
- Oxidation (1)
- PAH (1)
- PCB (1)
- PDB (1)
- PLS-DA (1)
- Passive sampling (1)
- Pentachlorophenol (1)
- Pflanzenwachstum (1)
- Phase I metabolism (1)
- Phosphous recovery (1)
- Photometric P determination (1)
- Polybrominated biphenyls (PBBs) (1)
- Polybrominated diphenyl ethers (PBDEs) (1)
- Polycyclic aromatic hydrocarbons (1)
- Polymer (1)
- Polypropylene (1)
- Polystyrene (1)
- Polyurethane (1)
- Polyurethanes (1)
- Predicting sites of metabolism (1)
- Probe (1)
- Probenahme (1)
- Process water (1)
- Proficiency Testing (1)
- Proficiency test (1)
- Pulverization (1)
- Pumpprobe (1)
- Pyrolysis (1)
- QM (1)
- Quality assurance (1)
- Qualitätsmanagement (1)
- Qualitätssicherung (1)
- R factor = 0.043 (1)
- Rainwater (1)
- Raman imaging (1)
- Rate matrix (1)
- Rearrangement (1)
- Reference material (1)
- Reference organisms (1)
- Referenzmaterial (1)
- Referenzmaterialien (1)
- Regulation (1)
- Remediation (1)
- Reproducibility (1)
- Ring test (1)
- Ring test structure (1)
- SEC (1)
- SPME (1)
- Safety (1)
- Sample (1)
- Sediment (1)
- Shelf life (1)
- Simulation (1)
- Single-crystal X-ray study (1)
- Sniffer dogs (1)
- Society of hair testing (1)
- Software (1)
- Sonication (1)
- Sorption (1)
- Stabilisation (1)
- Stability (1)
- Stakeholders (1)
- Standardisation (1)
- Standardization (1)
- Static headspace (1)
- Statistical thermodynamics (1)
- Statistics (1)
- Support vector machines (1)
- Suspended organic matter (1)
- Synthesis (1)
- Synthetic air (1)
- T = 273 K (1)
- TBBPA-dbpe (1)
- TED-GC-MS (1)
- TFA (1)
- Thermal degradation (1)
- Thermo-desorption (1)
- Total organic carbon (1)
- Total petroleum hydrocarbons (1)
- Trace elements (1)
- Traceability (1)
- Trichloroethene (1)
- Umweltanalytik (1)
- Urine (1)
- Vinyl chloride (1)
- Waste (1)
- Waste ecotoxicity (1)
- Waste legislation (1)
- Waste wood (1)
- Wastewater (1)
- X-ray (1)
- X-ray analysis (1)
- X-ray structure analyses (1)
- Zinc (1)
- dog training (1)
- herbs (1)
- reference materials, (1)
- scent dog (1)
- smell (1)
- training model (1)
- wR factor = 0.121 (1)
Organisationseinheit der BAM
- 1 Analytische Chemie; Referenzmaterialien (19)
- 1.7 Organische Spuren- und Lebensmittelanalytik (19)
- 4 Material und Umwelt (4)
- 6 Materialchemie (4)
- 5 Werkstofftechnik (3)
- 6.3 Strukturanalytik (3)
- 4.3 Schadstofftransfer und Umwelttechnologien (2)
- 5.3 Polymere Verbundwerkstoffe (2)
- 6.6 Physik und chemische Analytik der Polymere (2)
- 1.2 Biophotonik (1)
Paper des Monats
- ja (1)
In this paper, we investigate the interconversion processes of the major flame retardant - 1,2,5,6,9,10-hexabromocyclododecane (HBCD) - by the means of statistical thermodynamics based on classical force-fields. Three ideas will be presented. First, the application of classical hybrid Monte-Carlo simulations for quantum mechanical processes will be justified. Second, the problem of insufficient convergence properties of hybrid Monte-Carlo methods for the generation of low temperature canonical ensembles will be solved by an interpolation approach. Furthermore, it will be shown how free energy differences can be used for a rate matrix computation. The results of our numerical simulations will be compared to experimental results.
On-line coupled high performance liquid chromatography-gas chromatography-flame ionisation detection (HPLC-GC-FID) was used to compare the effect of hydrogen, helium and nitrogen as carrier gases on the chromatographic characteristics for the quantification of mineral oil hydrocarbon (MOH) traces in food related matrices. After optimisation of chromatographic parameters nitrogen carrier gas exhibited characteristics equivalent to hydrogen and helium regarding requirements set by current guidelines and standardisation such as linear range, quantification limit and carry over. Though nitrogen expectedly led to greater peak widths, all required separations of standard compounds were sufficient and humps of saturated mineral oil hydrocarbons (MOSH) and aromatic mineral oil hydrocarbons (MOAH) were appropriate to enable quantitation similar to situations where hydrogen or helium had been used. Slightly increased peak widths of individual hump components did not affect shapes and widths of the MOSH and MOAH humps were not significantly affected by the use of nitrogen as carrier gas. Notably, nitrogen carrier gas led to less solvent peak tailing and smaller baseline offset. Overall, nitrogen may be regarded as viable alternative to hydrogen or helium and may even extend the range of quantifiable compounds to highly volatile hydrocarbon eluting directly after the solvent peak.
In recent years, an increasing trend towards investigating and monitoring the contamination of the environment by microplastics (MP) (plastic pieces < 5 mm) has been observed worldwide. Nonetheless, a reliable methodology that would facilitate and automate the monitoring of MP is still lacking. With the goal of selecting practical and standardized methods, and considering the challenges in microplastics detection, we present here a critical evaluation of two vibrational spectroscopies, Raman and Fourier transform infrared (FTIR) spectroscopy, and two extraction methods: thermal extraction desorption gas chromatography mass spectrometry (TED-GC-MS) and liquid extraction with subsequent size exclusion chromatography (SEC) using a soil with known contents of PE, PP, PS and PET as reference material. The obtained results were compared in terms of measurement time, technique handling, detection limits and requirements for sample preparation. The results showed that in designing and selecting the right methodology, the scientific question that determines what needs to be understood is significant, and should be considered carefully prior to analysis. Depending on whether the object of interest is quantification of the MP particles in the sample, or merely a quick estimate of sample contamination with plastics, the appropriate method must be selected. To obtain overall information about MP in environmental samples, the combination of several parallel approaches should be considered.
Three chromatographic procedures were investigated regarding their potential for the quantification of aniline and 19 of its methylated and chlorinated derivatives in groundwater. These methods were based on liquid-liquid-extraction in combination with gas chromatography and single quadrupole mass spectrometry (GC/MS) according to German standard DIN 38407-16:1999 and its extension using tandem mass spectrometry (GC/MS-MS), both following liquid-liquid extraction, and as third alternative the direct injection of the water sample into a liquid chromatograph coupled to tandem mass spectrometry (LC/MS-MS). Results were compared using fortified water and real-world contaminated groundwater used in an interlaboratory comparison. It could be shown that GC/MS and GC/MS-MS yielded results deviating less than 10% from each other while all three procedure displayed quantification results deviating less than 15% from the intercomparison reference values in case of each analyte in the concentration range between 1 and 45 µg L-1. Though GC/MS-MS displays a ten-fold higher sensitivity than single quadrupole GC/MS, the precision of both methods in the concentration range was similar. LC/MS-MS has the advantage of no further sample preparation due to the direct injection and leads for methylanilines and meta-, para- substituted chloroanilines to results sufficiently equivalent to the standardised GC/MS method. However, LC/MS-MS is not suitable for ortho-chloroaniline derivates due to significantly lower ion yields than meta- and para-substituted chloroanilines.
The design and operation of an observational study on the profiles of volatile organic compounds (VOC) in the breath of 37 lung cancer patients and 23 healthy controls of similar age is outlined. The necessity to quantify each VOC considered as potential disease marker on basis of individual calibration is elaborated and the quality control measures required to maintain reproducibility in breath sampling and subsequent instrumental trace VOC analysis using SPME-GC-MS over a study period of 14 months are described. 24 VOC were quantified on basis of their previously suggested potential as cancer markers. The breath concentration levels of aromatic compounds was expectedly increased in smokers while lung cancer patients displayed significantly increased levels of oxygenated VOC such as aldehydes, 2-butanone and 1-butanol. Though sets of selected oxygenated VOC displayed sensitivities and specificities between 80 and 90% using linear discriminant analysis with leave-one-out cross validation the effective selectivity of the breath VOC approach with regard to cancer detection is clearly limited. Results were discussed against the background of the literature on volatile cancer marker investigations and the prospects to link increased VOC levels in patients’ breath with approaches to employ sniffer dogs. Experiences from this study and the literature suggest that the current state of breath VOC based discrimination between cancer patients and healthy controls is hardly improvable. Observational studies tend to observe significant differences mostly in levels of certain oxygenated VOC but without resolution required for practical application. Any step towards practicable exploitation of VOC profile differences for illness detection would have to solve current restrictions set by the low and variable VOC concentrations. Further challenges are the technical complexity of studies involving breath sampling and possibly the limited capability of current analytical procedures to detect instable marker candidates.
Decabromodiphenylethane
(2007)
Decabromodiphenylethane [systematic name: 1,1'-ethane-1,2-diylbis(pentabromobenzene)], C14H4Br10 (DBDPE), was crystallized from toluene. The molecule shows crystallographic inversion symmetry. The CBr distances are in the range 1.873 (7)1.891 (6) Å; intermolecular BrBr contacts contribute to the formation of ribbons.
The assessment of quantification results of the alcohol abuse marker ethyl glucuronide (EtG) in hair in comparison to the cut-off values for the drinking behavior may be complicated by cosmetic hair bleaching. Thus, the impact of increasing exposure to hydrogen peroxide on the EtG content of hair was investigated. Simultaneously, the change of absorbance in the range of 1000–1100 cm-1 indicative for the oxidation of cystine was investigated non-destructively by attenuated total reflectance Fourier transform infrared spectroscopy (ATR-FTIR) using pulverized portions of the respective hair samples. Hair samples treated with hydrogen peroxide consistently displayed a significantly increased absorbance at 1040 cm-1 associated with the formation of cysteic acid. The EtG content decreased significantly if the hair was treated with alkaline hydrogen peroxide as during cosmetic bleaching. It could be shown that ATR-FTIR is capable of detecting an exposure to hydrogen peroxide when still no brightening was visible and already before the EtG content deteriorated significantly. Thus, hair samples suspected of having been exposed to oxidative treatment may be checked non-destructively by a readily available technique. This assay is also possible retrospectively after EtG extraction and using archived samples.
Delta-Hexabromocyclododecane
(2007)
The X-ray crystallographic study of the macrocyclic tetrakis-N[N-2-hydroxyethyl-piperazino]calix[4]resorcinarene·3CH3CH2OH·H2O (3) reveals a self-assembled dimeric capsule-like complex held together by an array of intermolecular hydrogen bonds. Pairs of concave molecules associate directly in bowl-to-bowl fashion and enclose an accessible supramolecular cavity of Å3 hosting one water and three ethanol molecules. The supramolecular arrangement displays alternating layers of facing bowls and interlocking lower rim aliphatic moieties. The helical conformation of the 2-hydroxyethyl piperazinomethyl moieties displays chirality of a bimolecular capsule frozen in the solid state. 3 crystallises in the triclinic space group P-1 with two symmetry independent molecules in the asymmetric unit. Two enantiomeric capsules form a racemic pair in the unit cell.
A combination of simultaneous milling and extraction known as micropulverized extraction was developed for the quantification of the alcohol marker ethyl glucuronide (EtG) in hair samples using a homogeneous reference material and a mixer mill. Best extraction results from 50 mg of hair were obtained with 2-mL plastic tubes containing two steel balls (Ø = 5 mm), 0.5 mL of water and with an oscillating frequency of 30 s-1 over a period of 30 min. EtG was quantified employing a validated GC-MS procedure involving derivatization with pentafluoropropionic acid anhydride. This micropulverization procedure was compared with dry milling followed by separate aqueous extraction and with aqueous extraction after manual cutting to millimeter-size snippets. Micropulverization yielded 28.0±1.70 pg/mg and was seen to be superior to manually cutting (23.0±0.83 pg/mg) and equivalent to dry grinding (27.7±1.71 pg/mg) with regard to completeness of EtG extraction. The option to process up to 20 samples simultaneously makes micropulverization especially valuable for the high throughput of urgent samples.
Determination of pentachlorphenol (PCP) in waste wood - method comparison by a collaborative trial
(2002)
Two independently developed and validated procedures for the determination of pentachlorophenol (PCP) in waste wood were compared by means of a collaborative trial. Both methods foresee quantification of PCP by gas chromatography (GC-ECD) after acetylation and differ with regard to the use of methanol or toluene/sulphuric acid, respectively, as solvent in the sonication extraction step. Test samples with established analyte homogeneity were prepared from a ground real life starting material. A total of 23 participating laboratories with experience in wood preservative analysis were instructed to apply both methods to three levels of content in the range of 0.520 mg PCP/kg. In case of the toluene/sulphuric acid extraction, lower recoveries and higher interlaboratory dispersion of results at the higher PCP contents were observed. Seen against the background of the Horwitz equation a reproducibility standard deviation of not, vert, similar19% for the methanol extraction at the 4.5 mg/kg level meets the requirement for a sound analytical method. Thus, the sonication extraction procedure with methanol has been annexed as a reference method to the German waste wood regulation.
A practical method for the quantification of
total purgeable organic sulfur (POS) in highly contaminated
groundwater is described. Volatile organic sulfur
compounds (VOSC) are purged from the water samples by
a stream of oxygen and combusted. The emerging sulfur
dioxide is absorbed in H2O2 and converted to sulfate which
is quantified by ion chromatography and reported as mass
sulfur equivalent. The overall limit of quantification is
0.03 mg l1. The content of POS is balanced with the total
VOSC determined by GC-AED after liquidliquid extraction.
Separate determination of the non-volatile organic
sulfur compounds by direct combustion of the water sample
and adsorption to charcoal yielded a mass balance of
the total sulfur content. Semi-quantitative GC-MS after
purge & trap accumulation revealed that the VOSC mixture
is composed of C1C4 alkyl sulfides. The implementation
of the developed methodology for the quantification of
VOSC as potential catalyst poison in a cleaning plant
for groundwater contaminated with volatile haloorganics
(VOX) is presented.
The statistical tool eCerto was developed for the evaluation of measurement data to assign property values and associated uncertainties of reference materials. The analysis is based on collaborative studies of expert laboratories and was implemented using the R software environment. Emphasis was put on comparability of eCerto with SoftCRM, a statistical tool based on the certification strategy of the former Community Bureau of Reference. Additionally, special attention was directed towards easy usability from data collection through processing, archiving, and reporting. While the effects of outlier removal can be flexibly explored, eCerto always retains the original data set and any manipulation such as outlier removal is (graphically and tabularly) documented adequately in the report. As a major reference materials producer, the Bundesanstalt für Materialforschung und -prüfung (BAM) developed and will maintain a tool to meet the needs of modern data processing, documentation requirements, and emerging fields of RM activity. The main features of eCerto are discussed using previously certified reference materials.
High-performance liquid chromatography tandem mass spectrometry (HPLC–MS/MS) was applied to sterospecifically quantify the content of α-, β-, and γ-hexabromocyclododecane (HBCD) in six fish species from the Norwegian Etnefjorden. A combination of a β-PM cyclodextrin and an achiral column enabled the paired chromatographic separation of the stereoisomers in the order (-)-α-, (+)-α-, (-)-β-, (+)-β-, (+)-γ- and, (-)-γ-HBCD. The limits of detection were in the range of 6–21 pg g-1 depending on the stereoisomer and the concentrations of α-, β-, and γ-HBCD in fillets ranged from <5.4 ng g-1 to 11.1 µg g-1 lipid weight. α-HBCD enantiomers were throughout dominating, and in most cases the accumulation of the respective first eluted enantiomers ((-)-α-, (-)-β- and (+)-γ-HBCD) was observed. Deviations from the racemic EF-value were considered to be significant if it was outside of the expanded uncertainty range for each of the racemic HBCD-ratios. The composition of HBCD isomers varied between the investigated fish species and the relative high values for the γ-HBCD concentrations for the bottom-dwellers flounder and thorny skate seems to echo the HBCD pattern of ocean sediments.
Enantiomerenspezifischer Vergleich von HBCD-Gehalten maritimer Lebewesen zweier norwegischer Fjorde
(2010)
1,2,5,6,9,10-Hexabromocyclododecane (HBCD) is a widely used flame retardant, which tends to persist in the environment and accumulates in biota. The six stereoisomers (three racemates named α-, β-, and γ-HBCD) of the technical mixture were isolated with high-performance liquid chromatography (HPLC). Direct separations were performed on a chiral stationary phase containing permethylated -cyclodextrin (NUCLEODEX -PM column) and the pure enantiomers of α-, β-, and γ-HBCD were physically characterized for the first time. The absolute configurations of all six isomers were determined by anomalous dispersion using single crystal X-ray crystallography. Optical rotations αD in tetrahydrofuran were +4.2/-4.0 (α-HBCD), +26.1/-27.5 (β-HBCD), and +68.0/-66.3 (γ-HBCD). The sense of rotation could be correlated with the absolute configurations of α-, β-, and γ-HBCD enantiomers and their order of elution on a chiral permethylated β-cyclodextrin-bonded stationary phase. The diastereomers α-, β-, and γ-HBCD displayed distinctly different melting points as well as 1H-, 13C NMR, and IR spectra.
The ecotoxicological characterization of waste is part of its assessment as hazardous or non-hazardous according to the European Waste List. For this classification 15 hazard criteria are derived from the Council Directive 91/689/EEC on hazardous waste. Some of the hazard criteria are based on the content of dangerous substances. The criterion H14 'ecotoxic' lacks of an assessment and testing strategy and no specific threshold values have been defined so far. Based on the recommendations of CEN guideline 14735 (2005), an international round robin test (ring test) was organized by the German Federal Environment Agency in order to define suitable test methods for the biological assessment of waste and waste eluates. A basic test battery, consisting of three aquatic and three terrestrial tests, was compiled. In addition, data were submitted for ten additional tests (five aquatic (including a genotoxicity test) and five terrestrial ones). The tests were performed with three representative waste types: an ash from an incineration plant, a soil containing high concentrations of organic contaminants (polycyclic aromatic hydrocarbons) and a preserved wood waste. The results of this ring test confirm that a combination of a battery of biological tests and chemical residual analysis is needed for an ecotoxicological characterization of wastes. With small modifications the basic test battery is considered to be well suitable for the hazard and risk assessment of wastes and waste eluates. All results and documents are accessible via a web-based data bank application.