Filtern
Erscheinungsjahr
Dokumenttyp
Schlagworte
- Brominated flame retardant (3)
- Extraction (3)
- Chiral separation (2)
- HPLC-MS/MS (2)
- Mass spectrometry (2)
- Volatilome (2)
- A549 (1)
- APCI (1)
- Absolute configuration (1)
- Adsorption (1)
Organisationseinheit der BAM
- 1 Analytische Chemie; Referenzmaterialien (3)
- 1.7 Organische Spuren- und Lebensmittelanalytik (3)
- 4 Material und Umwelt (2)
- 1.1 Anorganische Spurenanalytik (1)
- 1.4 Prozessanalytik (1)
- 1.8 Umweltanalytik (1)
- 4.0 Abteilungsleitung und andere (1)
- 4.1 Biologische Materialschädigung und Referenzorganismen (1)
- 4.2 Material-Mikrobiom Wechselwirkungen (1)
- 4.3 Schadstofftransfer und Umwelttechnologien (1)
A method for the determination of the novel brominated flame retardant tetrabromobisphenol A bis(2,3-dibromopropylether), 1,1'-(isopropylidene)bis[3,5-dibromo-4-(2,3-dibromo-propoxy)-benzene] (TBBPA-dbpe), was developed. Technical TBBPA-dbpe was purified and the results of a thorough physical characterisation are reported. The application of APCI-MS is discussed and the fragmentation patterns are described. Quantification of TBBPA-dbpe was done by HPLC-DAD using external calibration. The validation of the method was accomplished using sediment and sewage sludge samples spiked with defined amounts of authentic TBBPA-dbpe. The average recovery rates of TBBPA-dbpe from spiked samples ranged from 35 to 91% (sediment) and from 57 to 98% (sewage sludge) depending on the respective extraction method. Pressurised fluid extraction (PFE) and fluidised bed extraction were superior to classical Soxhlet and sonication procedures and yielded recovery rates between 90 and 98% with relative standard deviations of 2%. The limits of detection (DTC), identification (ID) and determination (DTM) using HPLC-DAD were 10, 21 and 30 ng g-1 in sediment and 22, 44 and 72 ng g-1 in sewage sludge, respectively.
1,2,5,6,9,10-Hexabromocyclododecane (HBCD) is a widely used flame retardant, which tends to persist in the environment and accumulates in biota. The six stereoisomers (three racemates named α-, β-, and γ-HBCD) of the technical mixture were isolated with high-performance liquid chromatography (HPLC). Direct separations were performed on a chiral stationary phase containing permethylated -cyclodextrin (NUCLEODEX -PM column) and the pure enantiomers of α-, β-, and γ-HBCD were physically characterized for the first time. The absolute configurations of all six isomers were determined by anomalous dispersion using single crystal X-ray crystallography. Optical rotations αD in tetrahydrofuran were +4.2/-4.0 (α-HBCD), +26.1/-27.5 (β-HBCD), and +68.0/-66.3 (γ-HBCD). The sense of rotation could be correlated with the absolute configurations of α-, β-, and γ-HBCD enantiomers and their order of elution on a chiral permethylated β-cyclodextrin-bonded stationary phase. The diastereomers α-, β-, and γ-HBCD displayed distinctly different melting points as well as 1H-, 13C NMR, and IR spectra.
The interconversion of the stereoisomers contained in technical 1,2,5,6,9,10-hexabromocyclododecane, a major brominated flame retardant increasingly found in the environment and in biota, was investigated at elevated temperatures. The application of pure enantiomers of the three constituents α-, β-, and γ-HBCD enabled the unambiguous elucidation of the individual isomerisation reactions as well as the quantification of all respective rate constants. At 160 °C the rate constants range over two orders of magnitude from 1.50 × 10-3 to 1.88 × 10-5 mol(%) s-1. A preliminary mechanistic explanation for the differences of the rate constants which govern the composition of HBCD diastereomers at equilibrium is given.
1,2,5,6,9,10-hexabromocyclododecane (HBCD), a widely used flame retardant, is an ubiquitous contaminant in
the environment. Still, only little is known about the distribution and behavior in the environment such as
bioaccumulation or biotransformation of HBCD stereoisomers. In order to investigate enrichment and possible
bioisomerization of HBCD stereoisomers, Mirror Carps were exposed to pure (+)- and (-)-γ-HBCD, randomly
sampled after a predefined specific period and subjected to enantiomer-specific determination of α-, β-, and γ-
HBCD. No evidence for the isomerization of HBCD stereoisomers was observed in Mirror Carp fillets.
An international intercomparison involving eight national metrology institutes (NMIs) was conducted to establish their current measurement capabilities for determining five selected congeners from the brominated flame retardant classes polybrominated diphenyl ethers and polybrominated biphenyls. A candidate reference material consisting of polypropylene fortified with technical mixtures of penta-, octa- and decabromo diphenyl ether and decabromo biphenyl, which was thoroughly assessed for material homogeneity and stability, was used as study material. The analytical procedures applied by the participants differed with regard to sample pre-treatment, extraction, clean-up, employed calibrants and type of calibration procedure as well as regarding analytical methods used for separation, identification and quantification of the flame retardant congeners (gas chromatography coupled to an electron capture detector (GC-ECD), gas chromatography-mass spectrometry in the electron ionisation mode (GC-EI-MS), gas chromatography-mass spectrometry in the electron capture negative ionisation mode (GC-ECNI-MS), and liquid chromatography-inductive coupled plasma-mass spectrometry (LC-ICP-MS)). The laboratory means agreed well with relative standard deviations of the mean of means of 1.9%, 4.8%, 5.5% and 5.4% for brominated diphenyl ether (BDE) 47, 183 and 209 and for the brominated biphenyl (BB) congener 209, respectively. For BDE 206, a relative standard deviation of 28.5% was obtained. For all five congeners, within-laboratory relative standard deviations of six measurements obtained under intermediate precision conditions were between 1% and 10%, and reported expanded measurements uncertainties typically ranged from 4% to 10% (8% to 14% for BDE 206). Furthermore, the results are in good agreement with those obtained in the characterization exercise for determining certified values for the flame retardant congeners in the same material. The results demonstrate the state-of-the-art measurement capabilities of NMIs for quantifying representative BDE congeners and BB 209 in a polymer. The outcome of this intercomparison (pilot study) in conjunction with possible improvements for employing exclusively calibrants with thoroughly assessed purity suggests that a key comparison aiming at underpinning calibration and measurement capability (CMC) claims of NMIs can be conducted.
Time courses of HBCD levels and enantiomeric signatures in herring gull eggs from the German coast
(2010)
The design and operation of an observational study on the profiles of volatile organic compounds (VOC) in the breath of 37 lung cancer patients and 23 healthy controls of similar age is outlined. The necessity to quantify each VOC considered as potential disease marker on basis of individual calibration is elaborated and the quality control measures required to maintain reproducibility in breath sampling and subsequent instrumental trace VOC analysis using SPME-GC-MS over a study period of 14 months are described. 24 VOC were quantified on basis of their previously suggested potential as cancer markers. The breath concentration levels of aromatic compounds was expectedly increased in smokers while lung cancer patients displayed significantly increased levels of oxygenated VOC such as aldehydes, 2-butanone and 1-butanol. Though sets of selected oxygenated VOC displayed sensitivities and specificities between 80 and 90% using linear discriminant analysis with leave-one-out cross validation the effective selectivity of the breath VOC approach with regard to cancer detection is clearly limited. Results were discussed against the background of the literature on volatile cancer marker investigations and the prospects to link increased VOC levels in patients’ breath with approaches to employ sniffer dogs. Experiences from this study and the literature suggest that the current state of breath VOC based discrimination between cancer patients and healthy controls is hardly improvable. Observational studies tend to observe significant differences mostly in levels of certain oxygenated VOC but without resolution required for practical application. Any step towards practicable exploitation of VOC profile differences for illness detection would have to solve current restrictions set by the low and variable VOC concentrations. Further challenges are the technical complexity of studies involving breath sampling and possibly the limited capability of current analytical procedures to detect instable marker candidates.
The validation of a robust quantification procedure for EtG in hair using GC–NCI–MS is presented. Aqueous extraction is followed by complete lyophylization of the extract and derivatization with pentafluoropropionic anhydride (PFPA) under controlled temperature and duration. Clean-up of extracts was dispensable and standard single quadrupole MS displayed sufficient selectivity and sensitivity. The method displayed a wide linearity range and enabled LOD of 0.68 pg/mg, LOQ of 2.4 pg/mg, and precision below 8.12%. Since EtG was seen to display prolonged stability in the aqueous extracts and after derivatization with PFPA this straightforward procedure allows a routine throughput of large quantities of samples with little proneness to procedural scatter of results. The method was applied to demonstrate the homogeneity of two hair reference materials with mean EtG contents of 8.48 pg/mg and 22.0 pg/mg. Aside from the application in homogeneity studies of hair reference materials predominantly in the concentration range of 10–50 pg/mg the method was also designed for daily routine quantification of real-world sample with regard to drinking behavior assessment.