Filtern
Dokumenttyp
- Beitrag zu einem Tagungsband (8)
- Zeitschriftenartikel (6)
- Vortrag (6)
- Posterpräsentation (6)
Schlagworte
- GMR (10)
- Neutron diffraction (5)
- Residual stress (5)
- Metal magnetic memory (4)
- Baustahl (3)
- GMR-Sensorik (3)
- Magnetic stray fields (3)
- Plastic deformation (3)
- Eigenspannungen (2)
- Low carbon steel (2)
Organisationseinheit der BAM
- 8 Zerstörungsfreie Prüfung (4)
- 8.4 Akustische und elektromagnetische Verfahren (4)
- 5 Werkstofftechnik (3)
- 5.2 Metallische Hochtemperaturwerkstoffe (3)
- 9 Komponentensicherheit (2)
- 5.1 Mikrostruktur Design und Degradation (1)
- 7 Bauwerkssicherheit (1)
- 7.1 Baustoffe (1)
- 8.5 Röntgenbildgebung (1)
- 9.2 Versuchsanlagen und Prüftechnik (1)
Eingeladener Vortrag
- nein (6)
Sicherheitsrelevante und zyklisch hoch belastete Bauteile erfordern zur Vermeidung von kostenintensiven Ausfällen besonders stabile Prozessparameter. Bereits sehr kleine Randzonenfehler können unter zyklischer Bauteilbelastung zu Risswachstum und letztendlich zum Bauteilversagen führen. Die frühzeitige Erkennung von Randzonenfehler in Hochleistungsbauteilen wie z.B. Zahnräder, Ritzelwellen und Kurbelwellen erfordert daher eine leistungsfähige zerstörungsfreie Oberflächenrissprüfung, die es ermöglicht in den hochbeanspruchten Funktionsflächen auch Härterisse, Schleifrisse oder Zundereinschlüsse zu detektieren.
Hierzu sind in den letzten Jahren einige neue, innovative Oberflächenprüfverfahren wie die laserangeregte Thermografie und die Streuflussprüfung mit hochauflösenden GMR-Sensoren oder magnetooptischen Verfahren entwickelt worden. Zusätzlich zur hohen Empfindlichkeit zeichnen sich diese innovativen Verfahren durch einen schnellen und teils auch berührungslosen Einsatz aus. Da die noch relativ neu-en Verfahren naturgemäß noch nicht normativ verankert sind, wurden auch bereits erste Validierungen durchgeführt. Um die Leistungsfähigkeit der Verfahren eingehend zu untersuchen, erfolgten Testreihen an verschiedenen Testkörpern in Bezug auf Ortsauflösung, Empfindlichkeit, Automatisierung und Bewertung der Messsig-nale.
Neben den neuen Verfahren und ihren ersten Schritten hin zur Validierung kamen als Referenz auch die „klassischen“ Verfahren der Magnetpulver- und Wirbelstromprüfung zum Einsatz, deren Leistungsfähigkeit durch angepasste Sondenentwicklung auch für sehr kleine Oberflächendefekte nochmals unter Beweis gestellt wurde. Zusätzlich wurde an einigen Testkörpern eine hochauflösende CT durchgeführt. Die Ergebnisse dieses Vergleiches werden vorgestellt und Möglichkeiten sowie Grenzen der einzelnen Verfahren herausgearbeitet.
Magneto-resistive (MR) sensor arrays are suited for high resolution eddy current testing (ET) of aerospace components due to two significant advantages compared to conventional coil systems. First, to obtain high spatial resolution they can be manufactured down to the µm-regime without losing their outstanding field sensitivity. Secondly, MR technology has a relatively frequency-independent sensitivity in the range of common ET-frequencies thus providing a benefit for low frequency applications.
This paper presents measurements using MR array probes consisting of 32 TMR-elements (tunnel magneto resistance), an ASIC, and subsequent readout components. A source for generating the eddy currents inside the material under test is also implemented onboard of the PCB. These probes were developed in the IMAGIC-project* for detection and imaging of surface breaking defects.
The performance of the new sensor system has been investigated for several mock-ups, Aluminum and Titanium plate specimens having small adjacent boreholes with diameter of 0.44 mm and micro notches in the µm-range, respectively. To compare our results we used conventional eddy current probes. The MR sensor elements have a length of around 60 µm leading to a nearly 'point like' measurement. Neighbouring boreholes (depth 0.25 mm) with a separation of 0.6 mm between their centres could be resolved with a good SNR, and more important, the boreholes could be confidently distinguished using the TMR-probes. In case of conventional probes a reliable separation was not possible. In this paper we present the MR-ET-probes of the IMAGIC consortium and a comparison with conventional techniques.
*The IMAGIC-project ('Integrated Magnetic imagery based on spIntronics Components', 2011 – 2014, project reference: 288381) was funded by the European Commission, Seventh Framework Programme. Further partners involved in the consortium beside BAM and CEA were INESC-ID and INESC-MN (Portugal), Sensitec GmbH (Germany), Tecnatom S.A. (Spain), and Airbus Group (France).
Magneto resistive (MR) sensors are suited for a wide range of different applications. Especially due to their small sizes and their frequency-independent behaviour, they are eligible candidates for non-destructive testing methods where high spatial resolution is required. The use of specialized magnetic field probes enables not only a defect evaluation, but also a localized characterization of ferromagnetic materials.
This paper presents some NDT (non-destructive testing) examples concerning magnetic flux leakage applications (MFL) and eddy current testing (ET). For MFL-testing we used an NDT-adapted GMR (Giant MR) sensor array for the detection of small inclusions in thin steel sheets. We also investigated the effects of microstructure on magnetic properties using GMR sensors. The ET-example describes an MR array probe consisting of 32 MR-elements, an ASIC, subsequent readout components and a one-wire excitation to generate eddy currents inside the material (developed in the EU-funded IMAGIC-project, 2011-2014, 7th Framework Programme). Using this MR-probe we achieved results with a better spatial resolved defect detection of neighbouring boreholes compared to “conventional” ET-probes.
Magneto resistance sensors like GMR (giant magneto resistance) or TMR (tunnel magneto resistance) are widely used in industrial applications, examples are position measurement and read heads of hard disk drives. However, in case of non-destructive testing (NDT) applications these sensors, although their properties are outstanding like high spatial resolution, high field sensitivity, low cost and low energy consumption, never reached a technical transfer to an application beyond sci-entific scope.
This paper deals with benefits of GMR/TMR sensors in terms of high spatial resolution testing for different NDT applica-tions. The first example demonstrates the preeminent advantages of MR-elements compared with conventional coils used in eddy current testing (ET). The probe comprises one-wire excitation with an array of MR elements. This led to a better spatial resolution in terms of neighboring defects.
The second section concentrates on MFL-testing (magnetic flux leakage) with active field excitation during and before test-ing. The latter illustrated the capability of highly resolved crack detection of a crossed notch. This example is best suited to show the ability of tiny magnetic field sensors for magnetic material characterization of a sample surface. Another example is based on characterization of samples after tensile test. Here, no external field is applied. The magnetization is only changed due to external load and magnetostriction leading to a field signature which GMR sensors can resolve. This gives access to internal changes of the magnetization state of the sample under test.
Austenitic stainless steels provide a beneficial combination of chemical and mechanical properties and have been used in a wide field of applications for over 100 years. Further improvement of the chemical and mechanical properties was achieved by alloying nitrogen. But the solubility of N within the melt is limited and can be increased in substituting Ni by Mn and melting under increased pressure. In order to avoid melting under pressure and decrease production costs, a part of N can also be substituted by C. This leads to austenitic high interstitial steels (AHIS). Within the solution annealed state strength and ductility of AHIS is comparable or even higher of those of AHNS and can be further improved by cold working. Unfortunately the endurance limit does not follow this trend as it is known from cold-worked austenitic CrNi steels. This is due to the differences of the slip behavior which is governed by the stacking fault energy as well as other near field effects. Construction components operating under cyclic loads over long periods of time cannot be considered being free of voids or even cracks. Thus the crack propagation behavior is of strong interest as well. This contribution presents the tensile, fatigue, crack propagation and fracture toughness properties of AHNS and AHIS in comparison to those of CrNi-steels. The differences are discussed in relation to microstructural characteristic as well as their alterations under cyclic loading.
Giant magneto-resistive (GMR) sensor based metal magnetic memory (MMM) technique is proposed for mapping of deformation-induced self-magnetic leakage fields (SMLFs) in carbon steel. The specimens were subjected to different amounts of tensile deformation and the deformation-induced SMLFs were measured using a GMR sensor after unloading the specimens. 3D-nonlinear finite element modeling was performed to predict stress–strain state in a steel specimen under tensile load. The experimentally obtained SMLF images were correlated with the finite element model predicted stress–strain states. Studies reveal that the MMM technique can detect the plastic deformation with signal-to-noise ratio better than 20 dB. The technique enables the mapping of plastic deformation in carbon steels for the evaluation of the severity of deformation. The study also reveals that deformation-induced SMLF is influenced by the presence of initial surface residual stress, introduced by shot peening. The intensity of SMLF signal is found to increase with increase in tensile load and decrease with shot peening.
It is widely accepted that the magnetic state of a ferromagnetic material may be irreversibly altered by mechanical loading due to magnetoelastic effects. A novel standardized nondestructive testing (NDT) technique uses weak magnetic stray fields, which are assumed to arise from inhomogeneous deformation, for structural health monitoring (i.e., for detection and assessment of damage). However, the mechanical and microstructural complexity of damage has hitherto only been insufficiently considered. The aim of this study is to discuss the phenomenon of inhomogeneous “self-magnetization” of a polycrystalline ferromagnetic material under inhomogeneous deformation experimentally and with stronger material-mechanical focus. To this end, notched specimens were elastically and plastically deformed. Surface magnetic states were measured by a three-axis giant magnetoresistant (GMR) sensor and were compared with strain field (digital image correlation) and optical topography measurements. It is demonstrated that the stray fields do not solely form due to magnetoelastic effects. Instead, inhomogeneous plastic deformation causes topography, which is one of the main origins for the magnetic stray field formation. Additionally, if not considered, topography may falsify the magnetic signals due to variable lift-off values. The correlation of magnetic vector components with mechanical tensors, particularly for multiaxial stress/strain states and inhomogeneous elastic-plastic deformations remains an issue.