The knowledge about energy release and transient behaviour of flash lamps, used as short-term energy source in flash thermography investigations, is essential for a quantitative analysis of the results as well as for simulations regarding such experiments. Usually, only a rectangular pulse shape of a typical duration of a few milliseconds is regarded when flash lamps pulses are described. This note considers the afterglow period of a flash lamp explicitly and shows that negligence of this afterglow effect leads to a systematic underestimation of the pulse length and the related total energy release. In the reported case, the intensity transient recorded by a Silicon photo diode was transformed into a temperature transient, allowing the study of the real energy release. It turns out that approximately only 50% of the entire pulse energy were released during the usually regarded period of 2.8 ms, while the other half was released within a period of 20 ms with an exponential decay.
As groundwork for thickness determination of polymeric surface protection systems for concrete, we present a method for measuring the thickness of isolated semitransparent solids using pulse thermography both in Transmission and reflection geometry. Since standard models do not capture semitransparency, an advanced analytical model by Salazar et al. is applied. Physical material parameters are deduced by fitting experimental data from samples of well-known
thickness. Using those, the thickness of samples of the material can be obtained by fitting, as demonstrated for different semitransparent polymer materials.
Flash lamps are widely used excitation sources in the field of non-destructive testing with active thermography. Though the realized energy density in front of the investigated object is a significant factor with regard to detection sensitivity, only few data concerning this issue have been published so far. It is shown here that local energy densities can be estimated by means of a simple metal plate, which exhibits a certain temperature increase after flash excitation. After discussing the underlying calorimetric principle the sensor concept is reviewed using constant blackbody radiation and short laser pulses, since both kinds of sources generate known energy densities. The relative uncertainty of measurements of the energy density is found to be in the range of 10%. The last part of the present paper describes an application for characterizing the radiation of a usual 6 kJ flash lamp. The energy conversion efficiency was found to be only about 11%.
Comparison of concepts for a point-shaped energy density detector after flash lamp excitation
(2016)
The paper describes investigations and Research work in order to develop a simple sensor for the quantification of spectral broadband energy Dissipation of flash lamps at any point in space. Such Flash lamps are often used as energy source during active thermography testing (TT). Here, the temperature transient of the sensor surface has to be recorded by the infrared camera that is already present. During the following data evaluation, the energy input into the investigated specimen can be determined. Two opposite concepts were considered: thermal thick and thermal thin probes. The direct comparison shows advantages for thermal thick probes based on the physics of thermal balance processes.
Cooling-down of thermal thick probes after flash excitation - A measure for the real energy density?
(2015)
Though flash lamps are one of the most applied heat sources in the field of Thermographic Testing (TT) using active thermography, only little is known about the actually achieved energy input into test objects. In this paper, an easy to realize sensor concept is proposed and experimentally evaluated. The concept is based on the measurement of the surface temperature of a thermal thick probe after flash excitation. After considering the sensor concept with FEM simulations the experimental investigation of four materials (two polymer and two building materials) is described. It will be shown that a suited coating is essential for the realization of the sensor concept. The experimental results prove the suitability of black rigid PVC as the most promising material. Using a coated PVC sample the energy density of short laser pulses, similar to flashes of flash lamps, could be determined exactly with an estimated relative uncertainty of only a few percent.
Pulse and flash thermography are experimental techniques which are widely used in the field of non-destructive testing for materials characterization and defect detection. We recently showed that it is possible to determine quantitatively the thickness of semitransparent polymeric solids by fitting of results of an analytical model to experimental flash thermography data, for both transmission and reflection configuration. However, depending on the chosen experimental configuration, different effective optical absorption coefficients had to be used in the model to properly fit the respective experimental data, although the material was always the same. Here, we show that this effect can be explained by the wavelength dependency of the absorption coefficient of the sample material if a polychromatic light source, such as a flash lamp, is used. We present an extension of the analytical model to describe the decay of the heating irradiance by two instead of only one effective absorption coefficient, greatly extending its applicability. We show that using this extended model, the experimental results from both measurement configurations and for different sample thicknesses can be fitted by a single set of parameters. Additionally, the deviations between experimental and modeled surface temperatures are reduced compared to a single optimized effective absorption coefficient.
Flash thermography is widely used in non-destructive testing and materials characterisation. The use of analytical modelling utilizing the Laplace transform allows one to calculate the temperature transients of flash-heated samples and therefore characterize them by fitting of the results of model calculations to experimental data. However, for samples with high thermal diffusivity or very thin samples, the temperature transient is strongly influenced by the temporal shape of the heating pulse, especially in reflection configuration. To incorporate this into the model, the temporal shape of the heating pulse and its Laplace transform have to be known. Here we present a close phenomenological approximation of the temporal shape of pulses of Xe-flash lamps. It is a non-stitched solution, has a simple Laplace transform and is suitable for different lamps and energy settings. As an example for a practical application of the pulse shape approximation, we use it to determine the thickness of polymer samples with thicknesses down to 80 µm by means of flash thermography, both in transmission and reflection configuration. Using a rectangular pulse shape or a delayed Dirac pulse shape, the thickness results are very sensitive to the start time of the fit and an additional calibration is needed.
Impact damages and delaminations in fibre-reinforced composites (FRC) might not be visible at the surface, but could have an influence on the resistance and on the long-term behaviour of the component. Therefore, and especially for safety relevant structures, non-destructive methods are required for the assessment of such damages.
Active thermography methods are suitable to characterize damages after loading using different kind of excitation techniques and various configurations of infrared (IR) camera and heating sources. Here, flash lamps, impulse excitation with infrared radiator and lock-in technique with halogen lamps or widened laser beams are suited. In addition, non-optical sources like sonotrodes (requiring direct contact to the structure) or induction generators (only suited for carbon fibre reinforced polymer (CFRP) structures) could be applied as well. For the investigation of the evolution of the damage during the impact, passive thermography can be applied in-situ. Elastic and plastic deformations alter the temperature of the structure and thus the temperature on the surface.
In this contribution, at first the general principles of quantitative defect characterisation in FRC using active thermography with flash, impulse and lock-in excitation are described. Optical and thermal properties of the FRC material and its anisotropy are considered. Results of phase differences obtained at flat bottom holes with flash and lock-in thermography are compared for qualifying both methods for quantitative defect characterization. Secondly, the damage evolution of CFRP and GFRP structures under impact load and static tensile loading is described. The spatial and temporal evolution of the surface temperature enables us to distinguish matrix cracks or fibre-matrix separation from delaminations between the layers. Afterwards, all results for loading defects, obtained by passive and active thermography, are compared with each other. Fig. 1 and 2 show the difference of passive and flash thermography obtained at impact and tensile loaded CFRP plates, respectively. As one purpose of these investigations is the development of standards within national (DIN) and European (CEN) standardisation bodies, new draft and final standards are presented and further needs are discussed at the end of the presentation.