Filtern
Erscheinungsjahr
Dokumenttyp
Schlagworte
- DNA (3)
- Mycoplasma (3)
- Explosives detection (2)
- Gated materials (2)
- Gesteuerte Materialien (2)
- Laser-induced periodic surface structures (LIPSS) (2)
- Mesoporous materials (2)
- Mesoporöse Träger (2)
- Niobium (2)
- Sensors (2)
Organisationseinheit der BAM
Living organisms constantly interact with their environment, including through the exchange of gases. Respiration and the release and uptake of volatile organic compounds (VOCs) create dynamic microenvironments in biological systems. Studying the kinetics of volatiles in biological systems requires expensive instruments, and data analysis is challenging. Therefore, we aimed to design a minimal analytical device for measuring the composition of gaseous mixtures in realtime.
We built the ‘Modular Biological Mass Spectrometer’ (MoBiMS) from 3D-printed parts and custom sensors to fit a wide array of experimental set-ups. We tested the chemical detection range and temporal resolution of the MoBiMS employing pure compounds and complex biological samples.
Compounds with a higher than 0.4 mmHg vapor pressure and a molecular weight up to 154 g/mol were reliably sensed within seconds. The generated electron impact (EI) spectra were directly comparable with standard databases like the NIST EI library. Under a direct analysis approach, the MoBiMS identified the characteristic odor of banana (Musa sp.), that is, isoamyl acetate; tracked the dynamics of CO2 release while the Alka-Seltzer® reaction occurred showed the kinetics of the transient production and consumption of carbon dioxide during photosynthesis. MoBiMS also discriminated between volatile compounds ions coming from tobacco (Nicotiana benthamiana) leaves and the surrounding air through untargeted analysis. The small footprint of the MoBiMS and its relatively low energy consumption facilitate in situ analyses, as an additional gas supply is not necessary with EI ionization. The MoBiMS is easy to assemble, and its construction and operation are very cost-efficient compared to commercial devices. The analytical performance of the MoBiMS is suitable for real-time studies of biological systems, environmental monitoring, and medical diagnostics.
The crystallization of calcium hydroxide (Ca(OH)2, CH, portlandite) is a key process during the early stages of cement hydration. In the present work, we have revisited the formation of this mineral through nucleation and growth from supersaturated aqueous solutions, in the light of the currently emerging picture of multistage “non-classical” crystallization. To that end, we developed a titration-based assay, in which stock solutions of both relevant ions are added simultaneously into a reservoir, where supersaturation increases slowly at constant stoichiometry until nucleation occurs. This procedure allows both pre- and early post-nucleation phenomena to be analyzed quantitatively. Complementarily, the early stages of portlandite mineralization were probed by various advanced characterization techniques, including cryo-transmission electron microscopy (cryo-TEM), in-situ small-angle X-ray scattering (SAXS), pair distribution function (PDF) analysis of high-energy X-ray scattering (HEXS) data, and analytical ultracentrifugation (AUC). The experimental data show that the formation of calcium hydroxide starts with the association of ions into complexes and clusters, which subsequently coalesce to form amorphous nanoparticles – much like what has been observed in the case of calcium carbonate and other prominent minerals. Subsequently, these particles aggregate and build networks, which eventually transform into hexagonal Ca(OH)2 crystals. The presence of a soluble polycarboxylate – as a known inhibitor of portlandite crystallization – does not change the main characteristics of this multistep nucleation pathway, but it proved capable of significantly extending the lifetime of the amorphous intermediate phase and thus delaying the transition to the final crystalline phase. Our observations confirm the notion that “non-classical” crystallization is a much more common phenomenon than initially believed – and that, for minerals forming in aqueous environments, it may actually be the rule rather than the exception.
We report the results of a Versailles Project on Advanced Materials and Standards interlaboratory study on the intensity scale calibration of x-ray photoelectron spectrometers using low-density polyethylene (LDPE) as an alternative material to gold, silver, and copper. An improved set of LDPE reference spectra, corrected for different instrument geometries using a quartz-monochromated Al Kα x-ray source, was developed using data provided by participants in this study. Using
these new reference spectra, a transmission function was calculated for each dataset that participants provided. When compared to a similar calibration procedure using the NPL reference spectra for gold, the LDPE intensity calibration method achieves an absolute offset of ∼3.0% and a systematic deviation of ±6.5% on average across all participants. For spectra recorded at high pass energies (≥90 eV), values of absolute offset and systematic deviation are ∼5.8% and ±5.7%, respectively, whereas for spectra collected at lower pass energies (<90 eV), values of absolute offset and systematic deviation are ∼4.9% and ±8.8%, respectively; low pass energy spectra perform worse than the global average, in terms of systematic deviations, due to diminished count rates and signal-to-noise ratio. Differences in absolute offset are attributed to the surface roughness of the LDPE induced by sample preparation. We further assess the usability of LDPE as a secondary reference material and comment on its performance in the presence of issues such as variable dark noise, x-ray warm up times, inaccuracy at low count rates, and underlying spectrometer problems. In response to participant feedback and the results of the study, we provide an updated LDPE intensity calibration protocol to address the issues highlighted in the interlaboratory study. We also comment on the lack of implementation of a consistent and traceable intensity calibration method across the community of x-ray photoelectron spectroscopy (XPS) users and, therefore, propose a route to achieving this with the assistance of instrument manufacturers, metrology laboratories, and experts leading to an international standard for XPS intensity scale calibration.
The lead authors failed to name two collaborators as co-authors. The authors listed should include:
Miss Claudia L. Compean-Gonzalez (ORCID:
0000-0002-2367-8450) and Dr. Giacomo Ceccone (ORCID:
0000-0003-4637-0771).
These co-authors participated in VAMAS project A27, provided data that were analyzed and presented in this publication (and supporting information), and reviewed the manuscript before submission.
El desarrollo de receptores sintéticos complejos basados en conceptos de la química supramolecular no garantiza en ocasiones un reconocimiento molecular selectivo. Una alternativa en ciertos aspectos más simple y prometedora es el empleo de materiales híbridos orgánico-inorgánicos preparados mediante la funcionalización de sólidos inorgánicos porosos con receptores sintéticos adecuados. El anclaje de estos sistemas coordinantes a un soporte sólido da lugar a ciertos efectos sinérgicos que no están presentes ni en el material inicial ni en el receptor por separado y que sugieren que estos nuevos materiales híbridos pueden ser empleados en el desarrollo de nuevos sensores y nuevos protocolos de reconocimiento molecular y/o iónico.
The development of synthetic receptors based in supramolecular chemistry concepts will no allow a selective molecular recognition. A more simple, convenient and innovative approach relies on the use of organic-inorganic hybrid materials. These hybrid materials will be prepared by the grafting of certain synthetic receptors onto porous inorganic solids. The grafting of these coordinating systems onto a solid support leads to synergic effects that are hardly achievable with only the synthetic receptors or the solids alone. The presence of these synergic effects suggests that these organic-inorganic hybrid materials will be used for the development of novel sensory systems and novel molecular and/or ionic recognitionprotocols.
A material testing program to characterize the concrete behavior under static and dynamic loads
(2010)
In this paper a comprehensive material testing program is described to characterize a German final repository concrete material (BERB1) subjected to static and dynamic loads. The BERB1 material was developed und specified by the German Bundesanstalt für Materialforschung und -prüfung (BAM) for targets used for drop tests according to the KONRAD requirements.
The testing consists of three concurrent laboratory experimental programs performed in the USA. An extensive preliminary testing program in Germany was performed to assure the required concrete specifications during fabrication and curing.
The first set of data is the static basic material test program consisting of structural tests to quantify macroscopic concrete properties under quasi-static loads. Cubic and cylindrical specimens are investigated under this effort. The second set of test data is from the static complete material test program, where cylindrical concrete specimens are subjected to a variety of quasi-static axial and radial stress and strain paths using a high-pressure hydraulic tri-axial chamber. The material is characterized for confining pressures up to 400 MPa. The third set of data is from the dynamic complete material test program, which uses a modified Split-Hopkinson Pressure Bar to induce dynamic compression and tension waves into cylindrical concrete specimens that generate strain-rates up to 400 s-1.
The ensemble of data generated in these experiments provides a complete set of data that effectively describes the behavior of this concrete and can be used to develop a constitutive calculation model. In addition, the results of the tests show a significant effect of moisture on the strength and rheology of this concrete for quasi-static pressures greater than 50 MPa. Numerical drop test simulations with the developed constitutive model in the Lagrangian finite element code, LS-DYNA, show good agreement with the experimental results from a BAM research project.
The use of gamma-hydroxybutyric acid (GHB) in drug-facilitated sexual assault has increased due to its availability and high solubility in aqueous solutions and alcoholic beverages, necessitating the development of rapid methods for GHB detection. In this respect, portable testing methods for use in the field, based on lateral flow assays (LFAs) and capable of detecting trace concentrations of target analytes, are particularly attractive and hold enormous potential for the detection of illicit drugs. Using this strategy, here we report a rapid, low cost, easy-to-handle strip-based LFA for GHB analysis employing a smartphone for fluorescence readout. At molecular signalling level, the ensemble is based on a Cu2+ complex with a tetradentate ligand and the fluorescent dye coumarin 343, which indicate GHB through an indicator displacement assay (IDA) in aqueous solution. When incorporated in a LFA-based strip test this system shows a detection limit as low as 0.03 μM for GHB in MES buffer solution and is able to detect GHB at concentrations of 0.1 μM in soft drinks and alcoholic beverages in only 1 min.