A procedure for the quantification of the PCB marker congeners 28, 52, 101, 138, 153, 180 in plastic waste form the recycling of cables in the range of content between 0.1 mg kg-1 and 20 mg kg-1 was validated. Representative reference materials for laboratory analyses were produced using granulates from different recycling processes. The method development included aspects of grinding, sieving, homogenising as well as the comparison of extraction methods and chromatographic conditions. The validated procedure foresees grinding of the technical sample to an upper particle size limit of 0.50 mm followed by extraction with an unpolar solvent such as n-hexane and gas chromatographic determination. LOD and LOQ for individual congeners ranged between 0.01 mg kg-1 and 0.08 mg kg-1. Electron capture detection (ECD) and mass selective detection (MS) were equivalent if chromatographic conditions were appropriately selected. The application of MS was advantageous in presence of significant amounts of interfering components which have been found in some cables.
Three reference materials containing the marker congeners in the range of 0.1 mg kg-15 mg kg-1 were submitted to a final validation intercomparison with 23 selected field laboratories using the developed method. Relative reproducibility standard deviations varied between 15% and 33%.
ISO Guide 35 deals with RM stability issues and scrutinizes the evaluation of stability testing results under the assumption that either there is no trend at all (a rather rare situation), or any observed deterministic change is insignificant and thus can be neglected. However, market demands for reliable reference materials are obviously not limited to stable or at least seemingly stable materials. In many analytical applications, analytes and measurands under consideration are known, or at least suspected, to be unstable on time scales that may vary widely from measurand to measurand. The Federal Institute for Materials Research and Testing (BAM) has developed (and successfully uses) an integrated approach in its certification practice. The approach is based on an initial stability study and subsequent post-certification monitoring. Data evaluation is model-based and takes advantage of all information collected in the stability testing scheme(s). It thus allows one to deal with any kind of instability observed, to assess limiting time intervals at any stress condition in the range tested, to estimate a final expiry date for materials with detected instabilities or the maximum admissible re-testing interval for seemingly stable materials, and to assess maximum admissible stress loads during delivery of the material to the customer. The article describes (and exemplifies) typical study layout, the model selection, and the integrated data assessment.
Evaluation of methods for the analysis of soils according to § 8 of the German Federal Soil Protection Act (BBodSchG)
The German Federal Soil Protection Act establishes the conditions for effective soil protection and remediation of contaminated sites. In the German Federal Soil Protection and Contaminated Sites Ordinance (BBodSchV) limiting values and methods for the determination of environmentally harmful substances in soils are fixed. The aim of this project was to evaluate selected methods by comparative investigations and proficiency testing schemes. New methods for the determination of inorganic and organic pollutants should be developed and compared with the existing standard
methods. Despite the widespread use of ICP-OES up to now no national or international standard is available for the determination of heavy metals in soil extracts with this analytical method. The influence of spectral and non spectral interferences on the accuracy of the results was systematically investigated, especially based on aqua regia soil extracts. Analyte concentration equivalents were determined, too. Based on these results a proposal for a standard was submitted to the corresponding working group of ISO TC 190.[...]
Die Normung von Analyseverfahren ermöglicht, dass Parameter unter standardisierten Bedingungen qualitätsgesichert ermittelt werden können. Insbesondere dann, wenn Verfahren in gesetzliche Regelwerke einfließen, ist es notwendig, dass die Ergebnisse sicher und vergleichbar sind und der Aufwand im Vollzug vertretbar ist. Derzeit werden viele Parameter in verschiedenen Verordnungen nach unterschiedlichen genormten Verfahren analysiert, was die Überwachungsarbeit erschwert und zudem unnötig teurer macht. Aus diesem Grund wir eine sogenannte horizontale Normung angestrebt, bei der geeignete Analyseverfahren auch Matrices-übergreifend genormt und anschließend EU-weit zitiert werden können. Grundvoraussetzung für die Verabschiedung als Norm ist die Validierung der Verfahren. Bereits vor einigen Jahren erteilte die EU ein Mandat an CEN (Europäisches Komitee zur Normung), um umweltrelevante Parameter Matrices-übergreifend zu validieren. Allerdings konnten nicht alle für diverse Verordnungsnovellen (z.B. Klärschlammverordnung) wichtigen Parameter im Rahmen dieses Projekts validiert werden. Aus diesem Grund wurde das aktuelle Vorhaben in den Umweltforschungsplan des BMUB aufgenommen und von der BAM durchgeführt. Im Forschungsvorhaben konnten im Bereich der anorganischen Parameter die CEN/TS 16170 (Elemente mit ICP-OES), CEN/TS 16171 (Elemente mit ICP-MS) und CEN/TS 16175-2 (Quecksilber mit CV-AFS) sowie im Bereich der organischen Parameter die CEN/TS 16181 (PAK mit HPLC und GC), die CEN/TS 16167 (PCB mit GC-MS und GC-ECD) und die CEN/TS 16190 (Dioxine, Furane und dl-PCB mit HR-GC-MS) für die Analyse von Klärschlamm, behandeltem Bioabfall und Boden erfolgreich validiert werden. Die validierten Verfahren stehen nun kurz vor der Verabschiedung als EN (Europäische Norm).