Filtern
Dokumenttyp
- Vortrag (9)
- Zeitschriftenartikel (8)
- Posterpräsentation (8)
- Beitrag zu einem Tagungsband (1)
Schlagworte
- Immunoassay (12)
- Bead-based assay (8)
- Anthropogenic markers (5)
- Diclofenac (4)
- SAFIA (4)
- Wastewater (4)
- Flow cytometry (3)
- Automation (2)
- Bead-based-assay (2)
- Caffeine (2)
Organisationseinheit der BAM
- 1 Analytische Chemie; Referenzmaterialien (10)
- 1.8 Umweltanalytik (10)
- 1.9 Chemische und optische Sensorik (2)
- 1.0 Abteilungsleitung und andere (1)
- 1.4 Prozessanalytik (1)
- 1.5 Proteinanalytik (1)
- 1.7 Organische Spuren- und Lebensmittelanalytik (1)
- 6 Materialchemie (1)
- 6.1 Oberflächen- und Dünnschichtanalyse (1)
Eingeladener Vortrag
- nein (8)
This short course offers an introduction in immunomicroarrays and its application in environmental, food and clinical analysis. Basic principles of microarray fabrication, including spotting techniques and immobilization chemistry are presented, as well as different immunoassay formats and data treatment strategies. Furthermore, principles of bead-based suspension arrays are introduced, including principles of ligand and receptor immobilization, encoding and read-out strategies.
Due to the demand of monitoring the water quality regarding emerging pollutants, such as drug residues, selective, high-throughput and multi-target analytical methods must be established. On the one hand, the influence of sewage on natural surface waters must be routinely monitored. On the other hand, estimation of removal efficiencies of pollutants, such as drug residues, is in the focus of industrial and public wastewater treatment. Immunoassays, such as ELISA, offer the possibility to be highly sensitive and selective due to the high target affine and specific recognition of antibodies to target molecules. Batch-wise processing in microtiter plates allow the necessary high-throughput, but only a single analyte can be determined within one measurement.
To overcome these disadvantages, we developed a four-plex micro-bead based flow cytometric assay, which is adaptable for the microtiter plate format. The modular and self-prepared bead support consists of polystyrene-core-silica-shell particles. While the polystyrene core is used for encoding, by introducing different amounts of fluorescent dyes, the silica-shell creates a solid-support for the immunoassay: The target analytes, three drugs, carbamazepine, diclofenac and caffeine and the f ecal marker isolithocholic acid are covalently coupled to amino-groups on the surface via NHS-chemistry. A competitive immunoassay is subsequently conducted in a simple mix-and-read procedure. Finally, we could use SAFIA to assess the influent of treated and untreated waste water on the Douro river estuary in Portugal. The results of the analysis are comparable to ELISA. However, measurements could be carried out in 25% the time of analysis.
Monitoring water quality regarding emerging pollutants, such as drug residues, demands for selective, high-throughput and multi-target analytical methods. On the one hand, the influence of sewage on natural surface waters must be routinely monitored. On the other hand, estimation of removal efficiencies of pollutants, such as drug residues, is in the focus of industrial and public wastewater treatment. Immunoassays, such as ELISA, offer the possibility to be highly sensitive and selective due to the high target affinity and specificity of target recognition by antibodies. Batch-wise processing in microtiter plates allows for the necessary high-throughput, but only a single analyte can be determined within one measurement.
To overcome these disadvantages, we developed a four-plex Suspension Array Fluorescence Immunoassay (SAFIA), which is adaptable for the microtiter plate format. The modular and self-prepared bead support consists of polystyrene-core silica-shell microparticles. While the polystyrene core is used for encoding, by introducing different amounts of fluorescent dyes, the silica shell creates a solid-support for the immunoassay: the target analytes, three drugs, carbamazepine, diclofenac and caffeine, and the fecal marker isolithocholic acid are covalently coupled to amino groups on the surface via NHS chemistry. Specific recognition of these haptens is accomplished by further introduction of PEG moieties, suppressing non-specific binding. A competitive immunoassay is subsequently conducted in a simple mix-and-read procedure, eliminating the demand for laborious washing steps and decreasing time-to-result. An automated flow cytometer is used for simultaneous decoding and quantification.
After optimization, the SAFIA showed limits of detection for all analytes in the low µg L 1 range, meeting the sensitivity criteria for wastewater analysis. Then, applicability of the SAFIA was studied on real wastewater samples from three different wastewater treatment plants in Berlin. The results were in good comparability to LC-MS/MS indicating high matrix stability. Moreover, the accuracy of the assay exceeded that of the respective ELISA. Finally, we used SAFIA to assess the influent of treated and untreated wastewater on the Douro river estuary in Portugal. The obtained results of the analysis were comparable to ELISA. However, the measurements by SAFIA could be carried out in one quarter the time of analysis required for ELISA.
Acknowledgements: The authors acknowledge financial support from Deutscher Akademischer Austauschdienst and from Fundação das Universidades Portuguesas under the protocol CRUP-DAAD (Ações Integradas Luso-Alemãs nºE-20/16, DAAD Zuwendungsvertrag 57212899).
Clinical, environmental, and food analysis, require efficient and accurate quantitative analysis. Immunoassays take advantage of highly selective and affine binding of an antibody towards an antigen, being easy-to-use and allowing for high sample throughput. However, common immunoassays, e. g. ELISA are not capable of multiplexed analysis, thus limiting possible applications. On the other hand, multi-analyte methods, e.g. liquid chromatographytandem mass spectrometry requires expensive equipment, trained analysts and the time of analysis usually limits sample throughput. This bottleneck can be overcome combining the suspension array technology, where particles are encoded to allow multiplexed detection, with fluorescence immunoassays to create suspension array fluorescence immunoassays (SAFIA).
Polystyrene core/silica shell microparticles serve as platform for SAFIA. While an encoding dye is introduced in the polystyrene core, the silica shell is used for immobilization: For competitive hapten immunoassays small molecules are immobilized on the surface, serving as a competitive binding site for selective antibodies. For quantification of proteins, antibodies can be immobilized on the surface and the sandwich immunoassay format can be employed. All mentioned immunoassays can be executed wash-free and highly parallelized, allowing up to 500 determinations within three hours. In contrast to ELISA, short incubation times, a wash-free mix-and-read procedure and automated flow-cytometric read-out makes SAFIA applicable for even non-trained personal.
SAFIA showed excellent performance in studies on the origin and fate of drug residues in waste water, which is important to assess clearance rates of wastewater treatment plants. Furthermore, SAFIA can be employed in environmental screenings, detecting pollution of natural river waters by tracking anthropogenic marker substances. It was successfully employed in clinical and food analysis applications, e.g. the quantification of the anti-inflammatory drug diclofenac in breast milk or the quantification of caffeine in beverages. Due to multiplexing capacities, SAFIA can significantly improve biotechnological processes, as in the screening of hybridoma cells for selective and efficient antibody production. For small molecule analytes, limits of detection down to 4 ng/L and for proteins below 25 ng/mL (IgG) were observed, which makes SAFIA applicable to all addressed analytical issues. Moreover, in the analysis of real-world samples, SAFIA shows higher accuracy in contrast to ELISA, indicating higher matrix stability and thus higher robustness in analysis.
Spheriplex multiplexed immunoassays: A practical tool for environmental, food and bioanalysis
(2019)
Clinical, environmental, and food analysis, require efficient and accurate quantitative analysis. Immunoassays take advantage of highly selective and affine binding of an antibody towards an antigen, being easy-to-use and allowing for high sample throughput. However, common immunoassays, e. g. ELISA are not capable of multiplexed analysis, thus limiting possible applications. On the other hand, multi-analyte methods, e.g. liquid chromatographytandem mass spectrometry requires expensive equipment, trained analysts and the time of analysis usually limits sample throughput. This bottleneck can be overcome combining the suspension array technology, where particles are encoded to allow multiplexed detection, with fluorescence immunoassays to create suspension array fluorescence immunoassays (SAFIA).
Polystyrene core/silica shell microparticles serve as platform for SAFIA. While an encoding dye is introduced in the polystyrene core, the silica shell is used for immobilization: For competitive hapten immunoassays small molecules are immobilized on the surface, serving as a competitive binding site for selective antibodies. For quantification of proteins, antibodies can be immobilized on the surface and the sandwich immunoassay format can be employed. All mentioned immunoassays can be executed wash-free and highly parallelized, allowing up to 500 determinations within three hours. In contrast to ELISA, short incubation times, a wash-free mix-and-read procedure and automated flow-cytometric read-out makes SAFIA applicable for even non-trained personal.
SAFIA showed excellent performance in studies on the origin and fate of drug residues in waste water, which is important to assess clearance rates of wastewater treatment plants. Furthermore, SAFIA can be employed in environmental screenings, detecting pollution of natural river waters by tracking anthropogenic marker substances. It was successfully employed in clinical and food analysis applications, e.g. the quantification of the anti-inflammatory drug diclofenac in breast milk or the quantification of caffeine in beverages. Due to multiplexing capacities, SAFIA can significantly improve biotechnological processes, as in the screening of hybridoma cells for selective and efficient antibody production. For small molecule analytes, limits of detection down to 4 ng/L and for proteins below 25 ng/mL (IgG) were observed, which makes SAFIA applicable to all addressed analytical issues. Moreover, in the analysis of real-world samples, SAFIA shows higher accuracy in contrast to ELISA, indicating higher matrix stability and thus higher robustness in analysis.
Due to the demand of monitoring the water quality regarding emerging pollutants, such as drug residues, selective, high-throughput and multi-target analytical methods must be established. On the one hand, the influence of sewage on natural surface waters must be routinely monitored. On the other hand, estimation of removal efficiencies of pollutants, such as drug residues, is in the focus of industrial and public wastewater treatment. Immunoassays, such as ELISA, offer the possibility to be highly sensitive and selective due to the high target affine and specific recognition of antibodies to target molecules. Batch-wise processing in microtiter plates allow the necessary high-throughput, but only a single analyte can be determined within one measurement.
To overcome these disadvantages, we developed a four-plex micro-bead based flow cytometric assay, which is adaptable for the microtiter plate format. The modular and self-prepared bead support consists of polystyrene-core-silica-shell particles. While the polystyrene core is used for encoding, by introducing different amounts of fluorescent dyes, the silica-shell creates a solid-support for the immunoassay: The target analytes, three drugs, carbamazepine, diclofenac and caffeine and the f ecal marker isolithocholic acid are covalently coupled to amino-groups on the surface via NHS-chemistry. A competitive immunoassay is subsequently conducted in a simple mix-and-read procedure. Finally, we could use SAFIA to assess the influent of treated and untreated waste water on the Douro river estuary in Portugal. The results of the analysis are comparable to ELISA. However, measurements could be carried out in 25% the time of analysis.
A bead suspension array for measuring emerging pollutants and anthropogenic markers in wastewater
(2016)
Background: The assessment of water quality demands for high-throughput and multi-target compatible analytical methods. On the one hand, the influence of sewage on natural surface waters must be routinely monitored - according to the European Water Framework Directive. On the other hand, estimation of removal efficiencies of pollutants, such as drug residues, is in the focus of industrial and public wastewater treatment. Immunoassays, such as ELISA, are often applied in this area owing to their cost-efficiency and high-throughput capability. However, it is only possible to measure a single analyte in one measurement. In contrast, array technology is capable for measuring multiple substances in parallel. Here we present a four-plex bead-based flow cytometric assay for measuring three drugs (carbamazepine, an anti-epileptic drug, diclofenac, an antiphlogistic and caffeine, a psychoactive substance) and the bile acid isolithocholic acid, which is proposed to be used as a fecal marker. The drugs can be detected from 1 to 4 µg/L and the bile acid can be detected up to 72 µg/L in wastewater, requiring a highly sensitive detection method.
Methods: We use core-shell particles as the spherical platform, consisting of a polystyrene core and a silica shell. Such beads can easily be encoded with an organic fluorophore in the core and functionalized with amino groups on the silica shell surface for creating binding sites for antibodies: Therefore, the marker substances are bound to the amino groups via NHS chemistry. The hybrid particles were synthesized in house. Polystyrene was chosen as core material because of its low density and high refractive index, both important requirements for the use in suspension arrays. Easy surface modifications using silane chemistry are accessible on the silica shell. For the determination of the pollutants, the beads are incubated with a mixture of the analyte-specific antibodies. The antibodies undergo a competitive reaction to bind the immobilized molecules on the surface of the beads or the free analyte in the solution, respectively. Bound antibodies can then be visualized via fluorophore-labelled secondary antibodies. For read-out a flow cytometer is used to virtually separate the different dye encoded beads and to measure the resulting Signal intensity of the immunoassay. A four-parametric function was used as calibration curve.
Results: In order to obtain highly selective binding of the antibodies, we investigated different types of silica shell surface modifications to overcome unspecific binding, finding that a PEG-modified surface is suitable to support our immunoassay format. Multiplexed small molecule detection can therefore be realized in a simple mix and read procedure without washing steps.
Conclusion: We presented a multiplexing suspension array for the detection of four marker substances in wastewater samples, based on an indirect immunoassay format with polystyrene core-silica shell microbeads. The resulting multiplexing assay is appropriate to detect the marker substances in the low µg/L range. Therefore, wastewater samples can be measured without further preconcentration.