Filtern
Dokumenttyp
Sprache
- Englisch (5)
Schlagworte
- Digitale Radiologie (2)
- Durchstrahlungsprüfung (2)
- Ethinylestradiol (2)
- Analysis (1)
- Biochar (1)
- Biosensor (1)
- Bioseparation (1)
- EE2 (1)
- Electrochemistry (1)
- Elektrochemisch (1)
Organisationseinheit der BAM
In this work, we report an electrochemical immunosensor to detect ethinylestradiol in water samples, using electrochemical impedance spectroscopy (EIS) as a detection technique. For the development of this immunosensor, the direct modification of the working electrode of a screen-printed carbon electrode was carried out. First, to reduce the resistance of the electrode, electroreduced graphene was incorporated on the surface.
Second, a porous gold structure was electrodeposited on reduced graphene by electrodeposition and the dynamic hydrogen bubble template assisted method. Thus, a marked increase in surface area was obtained for anti-EE2 antibodies immobilization. Subsequently, the specific anti-EE2 antibodies were covalently immobilized using α-lipoic acid for attaching them to the gold surface.
The electrode modified with the antibodies was incubated for 30 min in the samples containing EE2, producing the specific Antigen antibody binding. As the charge transfer resistance of a redox probe in the electrode surface is governed by the surface blocking effects, the charge transfer resistance was related to the amount of EE2 captured to realize a quantitative determination. For this, the EIS measurements were performed in a 4 mM [Fe(CN)6]4−/3− solution in 0.1 M KCl. The obtained Nyquist diagrams were adjusted using the Randles circuit as an equivalent circuit to obtain the corresponding resistances. The developed methodology showed good selectivity, precision, and sensitivity; although the LOD obtained was higher than those presented in other published articles, it turned out to be an alternative that allows the determination of ethinylestradiol using a simple disposable electrode.
The aim of this work is to evaluate the feasibility of the direct radiography on weld
inspection in oil pipelines and gas pipeline during the manufacturing process. To that, 6 specimens
with 6 different thickness and varied height of reinforced weld with 5 different kinds of defects
were made. All samples were radiographied using Class I films and flat panel. For all specimens the
inspection length was 8''. Thus, with the flat panel the detector-to-object distance varied so that it
may adequate to several diameters of the tubes.
The detector-to-object distance was calculated based on the physical size of the detector
taking into consideration a safe distance between the tube curvature and the flat panel extremities,
keeping the lowest possible magnification factor so that it could be obtained the length of the
inspection. Images with 6 integration time for each experimental arrangement were obtained.
The images obtained with the Flat Panel/YXLON system were analyzed according to their
quality by using the Contrast parameters (essential wire) (DNV 2007/ IS0 12096 with
reinforcement and ISO 10893-7 basis material), Basic Spatial Resolution BSR (ISO 10893-7)
and normalized signal-to-noise ratio - SNRN (ISO 10893-7) and by detectability using as reference
the conventional radiography.
The results showed that for all thickness, the exposure time used to meet the image quality
requirements were below with direct radiography. However the BSR were not reached for thickness
of 4.85, 6.40 and 9.67 mm, therefore the compensation principle established by ISO 10893-7 was
considered, that is, one more contrast wire for a less wire pair.
The digital technique proved to be more sensitive to real defects found on welds than the
conventional technique. Then it can be conclude that the digital radiography utilizing the flat panel
can be applicable to the oil and gas segment with advantages over conventional technique as to
quality aspects, productivity, environment, safety and health.
Towards the standardization of biochar analysis: the COST action TD1107 interlaboratory comparison
(2016)
Biochar produced by pyrolysis of organic residues is increasingly used for soil amendment and many other applications. However, analytical methods for its physical and chemical characterization are yet far from being specifically adapted, optimized, and standardized. Therefore, COST Action TD1107 conducted an interlaboratory comparison in which 22 laboratories from 12 countries analyzed three different types of biochar for 38 physical–chemical parameters (macro- and microelements, heavy metals, polycyclic aromatic hydrocarbons, pH, electrical conductivity, and specific surface area) with their preferential methods. The data were evaluated in detail using professional interlaboratory testing software. Whereas intralaboratory repeatability was generally good or at least acceptable, interlaboratory reproducibility was mostly not (20% < mean reproducibility standard deviation < 460%). This paper contributes to better comparability of biochar data published already and provides recommendations to improve and harmonize specific methods for biochar analysis in the future.
The synthetic estrogen ethinylestradiol (EE2) is an active component of oral contraceptives (OCs), considered as an endocrine disrupting compound (EDC). It is excreted from humans and released via sewage treatment plant effluents into aquatic environments. EDCs are any environmental pollutant chemical that, once incorporated into an organism, affects the hormonal balance of various species including humans. Its presence in the environment is becoming of great importance in water quality. This paper describes the development of an accurate, sensitive and selective method for capture, preconcentration and determination of EE2 present in water samples using: magnetic particles (MPs) as bioaffinity support for the capture and preconcentration of EE2 and a glassy carbon electrode modified with multi-walled carbon nanotubes (MWCNTs/GCE) as detection system. The capture procedure was based on the principle of immunoaffinity, the EE2 being extracted from the sample using the anti-EE2 antibodies (anti-EE2 Ab) which were previously immobilized on MPs. Subsequently the analyte desorption was done employing a sulfuric acid solution and the determination of the EE2 in the pre-concentrated solution was carried out by square wave voltammetry (SWV).
This method can be used to determine EE2 in the range of 0.03570 ng L-1 with a detection limit (LOD) of 0.01 ng L-1 and R.S.D. < 4.20%. The proposed method has been successfully applied to the determination of EE2 in water samples and it has promising analytical applications for the direct determination of EE2 at trace levels.
Digital radiography in the inspection of welded pipes to be installed under deep water offshore gas and oil pipelines, like a presalt in Brazil, in the paper has been investigated. The aim is to use digital radiography for nondestructive testing of welds as it is already in use in the medical, aerospace, security, automotive, and petrochemical sectors. Among the current options, the DDA (Digital Detector Array) is considered as one of the best solutions to replace industrial films, as well as to increase the sensitivity to reduce the inspection cycle time. This paper shows the results of this new technique, comparing it to radiography with industrial films systems. In this paper, 20 test specimens of longitudinal welded pipe joints, specially prepared with artificial defects like cracks, lack of fusion, lack of penetration, and porosities and slag inclusions with varying dimensions and in 06 different base metal wall thicknesses, were tested and a comparison of the techniques was made. These experiments verified the purposed rules for parameter definitions and selections to control the required digital radiographic image quality as described in the draft international standard ISO/DIS 10893-7. This draft is first standard establishing the parameters for digital radiography on weld seam of welded steel pipes for pressure purposes to be used on gas and oil pipelines.