Filtern
Dokumenttyp
Sprache
- Englisch (2)
Referierte Publikation
- ja (2)
Schlagworte
- Flame retardancy (2) (entfernen)
Bisphenol A polycarbonate/acrylonitrile–butadiene–styrene (PC/ABS) with and without bisphenol A bis(diphenyl phosphate) (BDP) and 5 wt.% zinc borate (Znb) were investigated. The pyrolysis was studied by thermogravimetry (TG), TG-FTIR and NMR, the fire behaviour with a cone calorimeter applying different heat fluxes, LOI and UL 94. Fire residues were examined with NMR. BDP affects the decomposition of PC/ABS and acts as a flame retardant in the gas and condensed phases. The addition of Znb results in an additional hydrolysis of PC. The fire behaviour is similar to PC/ABS, aside from a slightly increased LOI and a reduced peak heat release rate, both caused by borates improving the barrier properties of the char. In PC/ABS + BDP + Znb, the addition of Znb yields a borate network and amorphous phosphates. Znb also reacts with BDP to form alpha-zinc phosphate and borophosphates that suppress the original flame retardancy mechanisms of BDP. The inorganic–organic residue formed provides more effective flame retardancy, in particular at low irradiation in the cone calorimeter, and a clear synergy in LOI, whereas for more developed fires BDP + Znb become less effective than BDP in PC/ABS with respect to the total heat evolved.
The pyrolysis combustion flow calorimeter (PCFC) as a tool for assessing the flammability of a polycarbonate (bisphenol A)/acrylonitrilebutadienestyrene (PC/ABS) blend containing different flame retardants and additives was investigated. Strategies are proposed for analysing multi-step decomposition. The heat release capacity (HRC) and total heat release (HR), obtained by PCFC, are related to the char yield and the heat of complete combustion of the volatiles. Physical affects such as dripping, wicking, and sample thickness are not described, nor are chemical effects such as flame inhibition because pyrolysis and combustion are forced to completion on a small (milligram) sample. Varying the combustion temperature or oxygen concentration results in incomplete combustion as occuring in real fires. The correlations with flammability (UL 94, LOI) and forced flaming combustion in a cone calorimeter are discussed. The best correlation is found between HR and LOI. Reasonable correlation exists between HRC and char residue with the LOI and for HRC and HR with peak heat release rate (pHRR) in the cone calorimeter. Combining results from PCFC with those from oxygen bomb or cone calorimeter tests yields an additional understanding of fire behaviour.