Eingeladener Vortrag (wissenschaftliche Konferenzen)
- nein (19)
In this paper results of the experimental testing performed on brick masonry and earth block masonry are presented. The paper outlines the development of the testing procedures for two different types of anchors. For this purpose, two experimental campaigns of pull-out tests on masonry corner connections strengthened by metallic rod grouted were carried out. Experimental results proved that the implemented testing procedures are suitable to determine the most recurring failure modes of the anchor pins. Moreover, a procedure is proposed to estimate the capacity of grouted anchor pins based on experimental studies.
ln this paper a modelling approach is presented to reproduce the mechanical behaviour of sandwich panels via finite element analysis. Two types of panels were investigated in this scope of work. The first sandwich element was a textile reinforced concrete (TRC) panel with cellular lightweight concrete insulation and the second configuration was an ultra-high performances concrete (UHPC) panel with aerated autoclaved concrete insulation. The goal was to obtain a reliable numerical strategy that represents a reasonable compromise in terms of sufficient accuracy of the element characteristics and the computational costs. The results show the possibility of describing the composite action in a full sandwich panel. The achieved modelling approach will later be used for the optimization of TRC and UHPC panels in terms of minimizing the thickness, identifying the number and location of connectors, as well as evaluating varying anchorage Systems.
The current paper focuses on the determination of reliable numerical models of earth block masonry wallettes under different loading conditions. Uniaxial compression and diagonal compression tests were performed. Experimental behaviour was modelled with a non-linear model able to describe the cracking behaviour. The simplified approach based on macro-modelling shows a satisfactory accuracy and low computational costs. The results reproducing the uniaxial compression are in good correspondence with the post-elastic behaviour observed in the experimental campaign. The micro-modelling approach adopted to reproduce the shear behaviour, even with high computational cost, represents a suitable tool to predict the masonry collapse mechanism.
The awareness of the environmental impact of the building sector is increasing. Steel reinforced concrete is the most commonly used construction material, though with a high-embodied energy and carbon footprint. Large environmental gains may arise if an alternative to steel reinforced concrete is developed. In this context, ultra-high performance concrete (UHPC) materials are shown to be promising alternatives with advantages such as lower embodied energy and reduced environmental impact. Predictions suggest that UHPC composite elements for building envelopes could have other benefits such as an increased service life, optimised use of building area due to thinner elements and minimised maintenance due to the absence of reinforcement or use of non-corrosive reinforcing materials such as carbon fibres. In the framework of the H-HOUSE project funded by the European Commission, composite elements are developed. The aim is to create facade panels combining an autoclaved aerated concrete or cellular lightweight concrete insulation layer with an external UHPC supporting layer. To enhance occupant comfort and health, hygroscopic materials that are capable to buffer indoor air humidity shall be applied to the inside of such elements. Indoor air humidity levels are expected to be more stable, which shall subsequently improve the indoor climate and minimise potential decay to the construction.
This paper presents an innovative way to combine an external ultra-high performance concrete (UHPC) supporting layer with an insulation layer of autoclaved aerated concrete (AAC) or cellular lightweight concrete (CLC) to create light-weight façade elements, which are improved in functionality and in energy efficiency. The durability of the façade elements is improved by developing UHPC with self-cleaning properties. One approach is based on the photocatalytic activation of the external UHPC shell by incorporation of TiO2 particles. The second approach consists of the modification of the UHPC surface by micro structuring in combination with the application of water-repellent agents to create durable super hydrophobicity. The current results obtained from laboratory testing are promising and demonstrate the feasibility of the approaches.
Beton ist als Massenbaustoff vielseitig einsetzbar. Eine der neuesten Entwicklungen ist Ultrahochleistungsbeton (UHPC). Seine besonderen Eigenschaften ermöglichen eine zusätzliche Funktionalisierung der Oberflächen, da annähernd beliebige Mikrostrukturen exakt abgeformt werden können. So lassen sich beispielsweise Fassadenelemente aus UHPC bereits bei ihrer Herstellung im Betonfertigteilwerk mit selbstreinigenden Oberflächen ausrüsten. Eine andere Möglichkeit ist eine Anwendung als Datenspeicher. Wie das Beispiel der Schallplatte aus UHPC zeigt, lassen sich Muster, die hier die Schallinformationen enthalten, exakt von einer Matrize kopieren.
Multi residential buildings, developed as highly energy-efficient and airtight are nowadays often fitted with mechanical Ventilation Systems as a way to overcome shortcomings and even defects tinked to indoor climate. The presented study investigates the potential of low-emitting. natural building materials with hygroscopic properties to contribute to a healthy and comfortable indoor environment, while reducing the need for mechanical Ventilation.
A selection of natural building materials suitable for application as internal partition walls has been investigated with regards to their water vapour adsorption capacity.
Special emphasis was placed on the investigation of modified earth plasters as well as wood-based materials, used as wall lining to provide increased adsorption capacities.
In addition, tests on materials emissions (formaldehyde, VOCs, SVOCs and radon) as well as adsorption tests of airborne pollutants have been conducted in specially-designed fest chambers. All tests were performed at either the material or the component tevel.
Overall results to date suggest that natural materials contribute to an improved indoor environment quality through an increased moisture-buffering capacity, low emissions and the potential to adsorb airborne pollutants, therefore reducing the need for mechanical Ventilation.
In the beginning of the 1980s earth building has undergone a renaissance, which nowadays leads to an increasing use of load-bearing earth constructions and in particular, earth block masonry. At present, there are no common structural standards according to the semi-probabilistic design concept, which is the state-of-the-art in European standards.
A solid database is needed for the determination of the partial safety factor on the resistance side. Therefore, compressive strength tests were carried out with two types of earth blocks and two types of prefabricated earth mortar. The evaluation showed that the variation of the compressive strength was remarkably less than expected, which seems to indicate high quality standards of the components earth block and mortar with regard to industrial production.
On the basis of these results and together with the reliability method, a partial safety factor for earth block masonry subjected to compression was determined. The main aim of the research was the development of a first valid database for material parameters of earth block masonry with particular regard to statistical characteristics. The results showed that a common calculation method for earth block masonry based on partial safety factors following the valid masonry construction standard is feasible.
In this paper, a comparative study on the initial shear strength of
masonry with earth mortars is presented. Triplet tests were carried out to characterise the shear bond strength of five different types of earth mortar, three purely mineral and two with vegetable additives (wood and straw chaff), using calcium silicate blocks. In spite of their lower bulk densities, mortars with chaffs reached a value of compressive strength comparable to the values shown by the purely mineral mortars. The characteristic initial shear strengths of all the tested earth mortars were between two and five times higher than the minimum values for initial shear strengths required by standards.
To assess the influence of blocks pre-wetting, a comparison between calcium silicate blocks and earth blocks was performed to evaluate the results obtained from the standard test procedure compared to the more common practice of using earth mortars in combination with earthen blocks.
Mittels Wärmebehandlung lassen sich die hervorragenden Eigenschaften von UHFB nochmals verbessern. Die für eine optimale Umsetzung relevanten Randbedingungen werden aktuell in der Fachwelt diskutiert. In dieser Veröffentlichung werden die Ergebnisse eines Forschungsprojekts vorgestellt, das die Wirkung verschiedener Einflussgrößen bei der Wärmebehandlung auf die Eigenschaften von UHFB zum Thema hatte. Dabei wurden die Art des Schutzes gegen das Austrocknen, die Vorlagerungszeit und die Haltezeit variiert. Um die zugrunde liegenden Prozesse zu verstehen, wurde der Phasenbestand mittels Röntgendiffraktometrie untersucht. Die höchsten Druckfestigkeiten des UHFB ließen sich bei einer Wärmebehandlung mit Wasserlagerung erzielen, da hierbei eine weitere Hydratation begünstigt wird. Vergleichsweise niedriger waren die Steigerungen bei einer Behandlung mit Schutz vor Austrocknung, während eine ungeschützte Behandlung zu deutlich geringeren Festigkeiten führte. Die Vorlagerungszeit beträgt im Idealfall einige Tage, um die Ausbildung eines offenbar günstigen Ausgangsgefüges sicherzustellen. Die Haltezeit sollte möglichst ausgedehnt sein, weil die Hydratation entsprechend lange gefördert wird. Im oberflächennahen Bereich war unter bestimmten Bedingungen eine Zonierung zu beobachten, deren Ursachen und Folgen, insbesondere in Bezug auf die Dauerhaftigkeit, weitere Forschung erfordern.