Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (79)
- Beitrag zu einem Tagungsband (54)
- Beitrag zu einem Sammelband (25)
- Vortrag (8)
- Sonstiges (7)
- Buchkapitel (4)
- Posterpräsentation (3)
- Forschungsbericht (3)
Schlagworte
- X-ray refraction (19)
- Computed tomography (12)
- Synchrotron radiation (6)
- Nanoparticles (5)
- CFK (4)
- Computed Tomography (4)
- Diffuse background (4)
- Fluorescent screen (4)
- Keramik (4)
- Materialcharakterisierung (4)
Organisationseinheit der BAM
- 8 Zerstörungsfreie Prüfung (9)
- 5 Werkstofftechnik (8)
- 5.6 Glas (6)
- 8.5 Röntgenbildgebung (5)
- 8.0 Abteilungsleitung und andere (4)
- 6 Materialchemie (3)
- 6.1 Oberflächen- und Dünnschichtanalyse (3)
- 1 Analytische Chemie; Referenzmaterialien (2)
- 5.3 Polymere Verbundwerkstoffe (2)
- 7 Bauwerkssicherheit (2)
Eingeladener Vortrag
- nein (8)
Messung der empfundenen Geruchsintensität mit Multigas-Sensorsystemen, das Forschungsvorhaben SysPAQ
(2007)
Measuring perceived air quality and intensity by a Sensor System, the European Project SysPAQ
(2008)
Micro-computed tomography (µCT) provides quantitative three-dimensional information of bone around titanium implants similar to classical histology. The study, based on an animal model, using cuboid-shaped biofunctionalised Ti6Al4V implants with surrounding bone after 4 weeks, is performed using 3 µCT-systems with X-ray tubes, one synchrotron-radiation-based µCT-system (SRµCT), and classical histology. Although the spatial resolution of the µCTsystems is comparable, only the results of SRµCT agree with results of classical histology. The X-ray tube sources give rise to huge artefacts in the tomograms (interface scattering, beam hardening), which impaired the quantitative analysis of bone up to about 200 µm from the implant surface. Due to the non-destructive character of µCT the specimens can be subsequently examined by classical histology
without restriction. The quantitative comparison of bone formation uncovers the strong dependence of the detected amount of newly formed bone from the selected slice. This
implies the necessity of 3D analysis. SRµCT and classical histology prove that surface modifications of the titanium implant significantly influence the bone formation. Using SRµCT, the preparation artefacts due to cutting and polishing are excluded.
Analyser-based imaging expands the performance of X-ray imaging by utilizing not only the absorption properties of X-rays but also the refraction and scatter rejection (extinction) properties. In this study, analyser-based computed tomography has been implemented on imaging an articular cartilage sample, depicting substructural variations, without overlay, at a pixel resolution of 3.6 µm.