Filtern
Erscheinungsjahr
Dokumenttyp
- Beitrag zu einem Tagungsband (47)
- Zeitschriftenartikel (36)
- Vortrag (34)
- Posterpräsentation (19)
- Buchkapitel (6)
- Beitrag zu einem Sammelband (2)
- Sonstiges (1)
Sprache
- Englisch (106)
- Deutsch (38)
- Mehrsprachig (1)
Schlagworte
- Fire (15)
- LNG (7)
- Sloshing (7)
- LH2 (5)
- Vessels (5)
- MLI (4)
- Pressure vessel (4)
- Road tankers (4)
- Tanker (4)
- Turning maneuvers (4)
- BLEVE (3)
- Braking (3)
- Cargo (3)
- Driving (3)
- Dynamic loads (3)
- Experimental approach (3)
- GFRP (3)
- Hazmat (3)
- Lightweight design (3)
- Liquid cargo (3)
- Load transfer (3)
- Pendulum analogy (3)
- Rail damage (3)
- Railway (3)
- Simulation (3)
- Tank (3)
- Tanks (3)
- Braking in a turn (2)
- Capsizing (2)
- Cargo sloshing (2)
- Centre plate (2)
- Damage (2)
- Dangerous goods (2)
- Earthquake (2)
- Eisenbahnkesselwagen (2)
- Emergency (2)
- Energy dissipation (2)
- Experimental approaches (2)
- Experimental methods (2)
- Experimental modelling (2)
- Gefahrguttransport (2)
- LPG (2)
- Lateral load transfer (2)
- Lateral stability (2)
- Lebensdauer (2)
- Liquefied hydrogen (2)
- Liquefied natural gas (2)
- Maneuvers (2)
- Perturbation (2)
- Rail (2)
- Railways (2)
- Rhine river (2)
- Safe (2)
- Safety (2)
- Schadensursachen (2)
- Securement (2)
- Tankcontainer (2)
- Tankfahrzeuge (2)
- Test rig (2)
- Testing (2)
- Thermohydraulic (2)
- Transport externalities (2)
- Turning (2)
- Vehicle (2)
- ABS (1)
- Aerial survey (1)
- Ageing effects (1)
- Aircraft cabin air flow (1)
- Analytical solution (1)
- Assess (1)
- Assessing (1)
- Avoid (1)
- Axial cracks (1)
- B10 exposure (1)
- BAM-Liste (1)
- Beständigkeitsbewertung (1)
- Biofuels (1)
- Bogie design (1)
- Bogie´s yaw friction (1)
- Bogie´s yaw stiffness (1)
- Boiling (1)
- Braking event (1)
- Braking in a turn manoeuvre (1)
- Braking performance (1)
- Braking-in-a-turn maneuver (1)
- Braking-in-a-turn maneuvers (1)
- Carburizing (1)
- Cargo shifting (1)
- Center of gravity shifting (1)
- Ceramic liners (1)
- Change in tensile properties (1)
- Commidities (1)
- Commodities (1)
- Comparative assessment (1)
- Compoite Receptacle (1)
- Component integrity (1)
- Composites in fire (1)
- Computational fluid dynamics (1)
- Computational scheme (1)
- Conceptual design (1)
- Container (1)
- Continuous wavelet transform (1)
- Convex bottom (1)
- Crack detection (1)
- Crack opening area (1)
- Critical crack sizes (1)
- Cryogenic Vessels (1)
- Cryogenic storage tank (1)
- Decarbonization (1)
- Distribution during filling (1)
- Drag resistance (1)
- Driving style (1)
- Druckgefäße (1)
- Dry friction (1)
- Duplexstahl (1)
- Dynamic pressures (1)
- Eddy current (1)
- Empirical Mode Decomposition (1)
- Empirical mode decomposition (1)
- Energy (1)
- Energy efficiency (1)
- Energy losses in transportation (1)
- Energy saving (1)
- Energy saving potentials (1)
- Engineering design (1)
- Environmental assessment (1)
- Explosion (1)
- Explosive atmosphere (1)
- FEM (1)
- FKM polymer (1)
- FVK-Tanks (1)
- Fiction (1)
- Filling procedere (1)
- Finite element method (1)
- Fire prooving (1)
- Fire protection coating (1)
- Fire retardants (1)
- Fire safety composite tanks (1)
- Fire testing (1)
- Flaschen (1)
- Flüssiggas (1)
- Forschungsvorhaben (1)
- Fracture mechanics (1)
- Frame (1)
- Freight containers (1)
- Frequency analysis (1)
- Friction energy (1)
- Friction wear (1)
- Fuel consumption (1)
- Furnace design (1)
- GPS (1)
- GPS Scheme (1)
- GPS data (1)
- Gas Filling (1)
- Gas flaring (1)
- Gas mixtures (1)
- Gefahrgut (1)
- Gefahrgut-Tankschiff (1)
- Gefahrguttanks (1)
- Gefahrgutvorschriften (1)
- Geometrical analysis (1)
- German safety basis concept (1)
- Gravity response (1)
- Hazmat tanks (1)
- Health monitoring (1)
- Honeycomb structure (1)
- Hunting phenomenon (1)
- Hydrostatic pressure (1)
- Infrastructure (1)
- Infrastructure damage (1)
- Insulation (1)
- Interaction (1)
- Interaction simulator (1)
- Intumescent layer (1)
- Isolation (1)
- JetFire (1)
- Jetfire (1)
- Large scale fire test (1)
- Lateral load transfer ratio (1)
- Leak before break behaviour (1)
- Leakage (1)
- Lifetime extension (1)
- Lightweight tank (1)
- Limit load analysis (1)
- Liquefied Hydrogen (1)
- Liquefied Natural Gas (1)
- Liquid nitrogen (1)
- Material properties (1)
- Materials testing (1)
- Mechanical fatigue (1)
- Mechanical modelling (1)
- Mechanical prtoperties (1)
- Mechanical stress (1)
- Methods (1)
- Microspheres (1)
- Mitigate (1)
- Model validation (1)
- Modelling (1)
- Mud circulation system (1)
- Mud pumps (1)
- Multi-Layer Insulation (1)
- Multibody dynamics (1)
- Multilayer Insulation (1)
- Newton approach Ship stability (1)
- Non destructive testing (1)
- Nondestructive evaluation (1)
- Novel equipment (1)
- Numerical Simulation (1)
- Numerical simulation (1)
- PIV (1)
- Packagings for dangerous goods (1)
- Particle emissions (1)
- Pendulum-analogy (1)
- Perlite (1)
- Permeation (1)
- Pistons (1)
- Pitch instability (1)
- Plant life management (1)
- Plastic instability (1)
- Pool fire (1)
- Potentials (1)
- Pressure bottle (1)
- Pressurized Vessel, (1)
- Pressurized vessels (1)
- Propane storage tanks (1)
- Protection systems (1)
- Prüfstand (1)
- Prüftstand (1)
- Qualitative Vergleichskriterien (1)
- Qualitätssicherung (1)
- Quasistatic (1)
- Rail damage (1)
- Rail tank containment fire (1)
- Rail tankers (1)
- Rail vibrations (1)
- Railroad (1)
- Railway braking forces (1)
- Railway transportation (1)
- Railway vibration measurements (1)
- Rear-end crashes (1)
- Receptacle (1)
- Representative Scale Apparatus (1)
- Representative scale apparatus (1)
- Response behavior (1)
- Rig (1)
- Risikoakzeptanz (1)
- Risikovergleich Verkehrsmittel (1)
- River tankers (1)
- Road (1)
- Road transportation (1)
- Roadways (1)
- Rock wool (1)
- Roll reactions (1)
- Rolling resistance (1)
- Safety valves (1)
- Scheme (1)
- Schiffshavarie (1)
- Schwimmstabilität (1)
- Sealing materials (1)
- Selective carburizing (1)
- Self-aligning bogies (1)
- Self-centering mechanism (1)
- Simulating (1)
- Sloshing affects (1)
- Sloshing cargo (1)
- Sloshing effect (1)
- Sloshing, transition matrix approach (1)
- Solvents (1)
- Steam generator tube inspection (1)
- Steam generator tubes (1)
- Steering forces (1)
- Steering torques (1)
- Stored energy (1)
- Substructure failures (1)
- Subway (1)
- Subway system (1)
- Synthetic aperture focusing technique (1)
- Tank shape (1)
- Tank trailer (1)
- Tankdesign (1)
- Test (1)
- Test rigs (1)
- Thermal insulation (1)
- Thermal properties (1)
- Thermal properties of GRP (1)
- Thermal radiation (1)
- Thermal remote sensing (1)
- Thermohydraulics (1)
- Tiefkalt (1)
- Transfer (1)
- Transfer function (1)
- Transition matrix approach (1)
- Transport efficiency (1)
- Transport safety (1)
- Transportation energy (1)
- Transporttanks (1)
- Tribology (1)
- Trucking (1)
- Tube inspection (1)
- Turning forces (1)
- Type III composite pressure receptacles (1)
- Unfallfeuer (1)
- Unmodellvorschriften (1)
- Vehicle containers (1)
- Vehicle-Track (1)
- Vehicles (1)
- Vertical cylindrical tanks (1)
- Vibration signal analysis (1)
- Wasserdruckprüfung (1)
- Wheel forces (1)
- Wheel-forces (1)
- Wheel-rail friction coefficient (1)
- Wheel-rail tangential forces (1)
- Wheel-track interaction (1)
- Wheel/track interaction (1)
- Wärmebehandlung (1)
- Yaw resistance (1)
- Yaw stiffness (1)
- pressurized vessel (1)
Organisationseinheit der BAM
Eingeladener Vortrag
- nein (34)
A model of the cargo – ship interaction has been presented, for a navigation environment in which there is no waves, in which the ship lateral stability depends only on the manoeuver performed and the characteristics of the ship and cargo. Several simplifications have been introduced in the model, including the circular bottom of the ship, which facilitates the location of the buoyancy force on the ship, and the analogy of the sloshing cargo motion to a simple pendulum. Two forms of damping were introduced (river waters with the ship´s hull and the friction of the liquid inside the tanker walls), while the sliding motion of the ship when turning has been assumed as negligible. The results suggest that the sloshing cargo influences the lateral stability of the river tanker, with increases in the maximum roll angle from 15% to 40%, as a function of the speed and the fill level. The maximum roll angle has been found to occur at a 75% fill level, regardless of the ship speed.
The safety of any transport system depends on a multitude of conditions, parameters and circumstances. In this regard, the interaction of the carried Cargo with the carrying vehicle represents a factor influencing the overall safety of any transport. The effects of cargo on the vehicle have to do with the vibration or shifting of the cargo, affecting the lateral stability of the vehicles and the braking performance.
Such interaction has been associated to road crashes and maritime vehicles capsizing. Simulation of cargo-vehicle interaction thus represents an interesting Topic when a reduction in transport accidents is pursued. In this paper, the fundamentals principles for simulating the interaction of the liquid cargo and the carrying vehicle, is presented. In the case of a road transportation, the proposed simplified Simulation methodologies, show good agreement with a full-scale test.
An experimental testing rig has been proposed to study the dynamic interaction between a liquid cargo and the carrying vehicle during turning maneuvers. The basic operational principle of the testing rig consists in simulating the lateral accelerations associated to turning maneuvers through the use of a tilt table.
While the experimental capabilities of the testing rig include the analysis of the effects of the cars on the whole transport infrastructure, including sleepers and ballast, a first use of the rig considered the effect of sloshing cargo on the level of dynamic forces transmitted to the rails. Such test was used to validate a simplified theoretical approach consisting of a two degree-of-freedom double pendulum mechanical system, where a simple pendulum, representing the sloshing cargo, is articulated to the spring-supported vehicle chassis, which is modelled as an inverted torsional pendulum. While the theoretical results exhibit a high correlation with the experimental data, the main discrepancy between both outputs, relates with the frequency of the residual vibration, once the lateral acceleration input is ceased. Such difference in frequency, would imply an underestimation of the number of loading cycles to which the infrastructure is subjected. On the other hand, the peak values are within acceptable difference levels.
The importance of tanks for storing cryogenic fluids in the energy industry is increasing because of ongoing political conflicts and the implementation of more environmentally friendly energy sources. Key representatives for the application of cryogenic tanks are natural gas in the form of Liquefied Natural Gas (LNG) and hydrogen, e. g. in the form of Liquefied Hydrogen (LH2), for which significantly higher transport capacities can be achieved with the same transport volume using cryogenic storages than with storages based solely on overpressure.
What applies to all cryogenic transported fluids in common is their condition that must be maintained. Hence heat flows into the preserved fluid must be minimized. Thermal super Insulations (TSI) based on e. g. multilayer insulations (MLI), perlites, and vacuum are utilized for this purpose and have already proven themselves in similar applications. However, for the use of tanks for cryogenic fluids in the transport sector, there is insufficient knowledge regarding the course and consequences of incidents, which is due to the still short period of use and the few documented incidents, hence few investigations carried out in this field. Typical scenarios in the transport sector represent car accidents with collisions, fires, and their combination, which are associated with extraordinary loads on the tank.
The focus of this study is to investigate the behavior of TSI as a result of their thermal exposure to a heat source representing a fire. It is worth mentioning that this could lead to an increase of the heat flux into a tank by several orders of magnitude, and to permanent damage of the TSI, ultimately rapid release of flammable gas as well as a Boiling Liquide Expanding Vapour Explosion (BLEVE). For this purpose, a high temperature thermal vacuum chamber (HTTVC) has been developed that allows thermal loading of MLI or perlites in a vacuum and simultaneous measurement of heat flow through this TSI. The HTTVC is designed to represent realistic insulation conditions and to withstand thermal loads from typical design fires.
The HTTVC was applied to investigate TSI based on MLI and vacuum. It is shown that the thermal stress caused permanent damage to the TSI, with shrinkage, phase change, pyrolysis, and condensation being significant damage mechanisms. The results are relevant for the evaluation of accident scenarios and can thus contribute to the improvement of TSI and the development of emergency measures for the protection of persons and infrastructures.
Multilayer Insulation (MLI) is frequently used in vacuum conditions for the thermal insulation of cryogenic storage tanks. The severe consequences of the degradation of such materials in engulfing fire scenarios were recently evidenced by several large-scale experimental tests. In the present study, an innovative modelling approach was developed to assess the performance of heat transfer in polyester-based MLI materials for cryogenic applications under fire conditions. A specific layer-by-layer approach was integrated with an apparent kinetic thermal degradation model based on thermogravimetric analysis results. The modeling results provided a realistic simulation of the experimental data obtained by High-Temperature Thermal Vacuum Chamber tests reproducing fire exposure conditions. The model was then applied to assess the behavior of MLI systems for liquid hydrogen tanks in realistic fire scenarios. The results show that in intense fire scenarios degradation occurs rapidly, compromising the thermal insulation performances of the system within a few minutes.
Liquefied Hydrogen (LH2) or Liquefied Natural Gas (LNG)
establish themselves as important energy carriers in the transport
sector. Its storage requires tanks with Thermal Super Insulations
(TSI) to keep the transported fluid cold. TSI has proven itself in
various applications over a long time, but not in the land
transport sector, where accidents involving collisions, fires, and
their combination are to be expected. The focus of this study is
to investigate the behavior of different types of TSI when
exposed to a heat source that represents a fire. Therefore, a High-
Temperature Thermal Vacuum Chamber (HTTVC) was used that
allows the thermal loading of thermal insulation material in a
vacuum and measuring the heat flow through the TSI in parallel.
Within this study, 5 samples were tested regarding 3 different
types of MLI, rock wool, and perlites. The thermal exposure
caused different effects on the samples. In practice, this can be
connected to the rapid release of flammable gases as well as a
Boiling Liquid Expanding Vapour Explosion (BLEVE). These
results are relevant for the evaluation of accident scenarios, the
improvement of TSI, and the development of emergency
measures.
The interest in hydrogen-based green energy is increasing worldwide, and the same is true for hydrogen-powered vehicles. Among the possible solutions to store hydrogen in such vehicles, cryogenic tanks equipped with multi-layer insulation (MLI) are the most promising to increase the amount of energy stored per unit volume. However, MLI is affected by severe deterioration when exposed to an external source of heat such as a fire following a car accident, leaving the tank unprotected and leading to failure in a relatively short time. In this work, a one-dimensional model to evaluate MLI thermal degradation when a liquid hydrogen tank is exposed to fire is presented. The relevance of taking MLI degradation into account when simulating the pressure increase due to external fire exposure is here demonstrated through the analysis of several case studies. The results show that MLI systems performance depletes within a few minutes of exposure to hydrocarbon poolfire.
The dynamic response of a vehicle during braking is influenced by the tangential forces developed at the wheel-rail’s contact surface. The friction coefficient affects the load transfer from the wheel’s tread to the vehicle. In this work, the vibrations of a scale-down railway vehicle are monitored during braking and their relationship with the friction coefficient between wheel and rail is found out. The vehicle is instrumented with encoders, accelerometers, and is controlled via Bluetooth.
The tests are carried out with clean and friction-modified rails. The tangential forces transmitted from the wheel to the railcar’s body are visualized in time and frequency using a proposed correlation algorithm based on the outputs of the ContinuousWavelet Transform (CWT). The results demonstrate
that tangential forces have a significant impact on railway vehicles under conditions of high friction coefficients and large creep values.
Liquefied Hydrogen (LH2) or Liquefied Natural Gas (LNG) establish themselves as important energy carriers in the transport sector. Its storage requires tanks with Thermal Super Insulations (TSI) to keep the transported fluid cold. TSI has proven itself in various applications over a long time, but not in the land transport sector, where accidents involving collisions, fires, and their combination are to be expected. The focus of this study is to investigate the behavior of different types of TSI when exposed to a heat source that represents a fire. Therefore, a High-Temperature Thermal Vacuum Chamber (HTTVC) was used that allows the thermal loading of thermal insulation material in a vacuum and measuring the heat flow through the TSI in parallel. Within this study, 5 samples were tested regarding 3 different types of MLI, rock wool, and perlites. The thermal exposure caused different effects on the samples. In practice, this can be connected to the rapid release of flammable gases as well as a Boiling Liquid Expanding Vapour Explosion (BLEVE). These results are relevant for the evaluation of accident scenarios, the improvement of TSI, and the development of emergency measures.
The importance of tanks for storing cryogenic fluids in the energy industry is increasing because of ongoing political conflicts and the implementation of more environmentally friendly energy sources. Key representatives for the application of cryogenic tanks are natural gas in the form of Liquefied Natural Gas (LNG) and hydrogen, e. g. in the form of Liquefied Hydrogen (LH2), for which significantly higher transport capacities can be achieved with the same transport volume using cryogenic storages than with storages based solely on overpressure.
What applies to all cryogenic transported fluids in common is their condition that must be maintained. Hence heat flows into the preserved fluid must be minimized. Thermal super Insulations (TSI) based on e. g. multilayer insulations (MLI), perlites, and vacuum are utilized for this purpose and have already proven themselves in similar applications. However, for the use of tanks for cryogenic fluids in the transport sector, there is insufficient knowledge regarding the course and consequences of incidents, which is due to the still short period of use and the few documented incidents, hence few investigations carried out in this field. Typical scenarios in the transport sector represent car accidents with collisions, fires, and their combination, which are associated with extraordinary loads on the tank.
The focus of this study is to investigate the behavior of TSI as a result of their thermal exposure to a heat source representing a fire. It is worth mentioning that this could lead to an increase of the heat flux into a tank by several orders of magnitude, and to permanent damage of the TSI, ultimately rapid release of flammable gas as well as a Boiling Liquide Expanding Vapour Explosion (BLEVE). For this purpose, a high temperature thermal vacuum chamber (HTTVC) has been developed that allows thermal loading of MLI or perlites in a vacuum and simultaneous measurement of heat flow through this TSI. The HTTVC is designed to represent realistic insulation conditions and to withstand thermal loads from typical design fires.
The HTTVC was applied to investigate TSI based on MLI and vacuum. It is shown that the thermal stress caused permanent damage to the TSI, with shrinkage, phase change, pyrolysis, and condensation being significant damage mechanisms. The results are relevant for the evaluation of accident scenarios and can thus contribute to the improvement of TSI and the development of emergency measures for the protection of persons and infrastructures.
The number of vehicles using or transporting cryogenic fuels such as Liquefied Hydrogen (LH2) or Liquefied Natural Gas (LNG) increases fast in the land transportation sector. Does this also entail new risks? The storage of cryogenic fuels requires tanks with Thermal Super Insulations (TSI) to keep the fluid cold and limit the formation of boil-off gas. TSI has proven itself in some applications since the middle of the 20th century, but in the land transport sector they are still quite new, where accidents involving fires, collisions, and their combination are to be expected. This work focuses on investigating the behavior of different types of TSI while exposed to a heat source representing a fire. To this aim, a High-Temperature Thermal Vacuum Chamber (HTTVC) was applied, which allows the thermal loading of a thermal insulation material in a vacuum and measuring the heat flow transported through the TSI in parallel. In this study, the results of 6 samples are presented regarding 3 types of MLI, rock wool, perlites, and microspheres. The thermal exposure caused different effects on the samples. In practice, this can be connected to the rapid release of flammable gases as well as to a Boiling Liquid Expanding Vapour Explosion (BLEVE). These results are relevant for reducing the risks to people and infrastructures in the progressive establishment of tanks for cryogenic fluids in our industry and society. The data presented in the study can be used to improve the design of tanks and TSIs, the assessment of accident scenarios, and the development of measures for first responders.
In the course of decarbonizing the energy industry, cryogenic energy carriers as liquefied hydrogen (LH2) and liquefied natural gas (LNG) are seen as having great potential. In technical applications, the challenge is to keep these energy carriers cold for a long time. This is achieved in the road transport sector and also stationary applications by thermal super insulations (TSI) which based on double-walled tanks with vacuum and multilayer insulation (MLI) in the interspace. This study focuses on the behaviour of widely used combustible MLI in a fire scenario, at vacuum and atmospheric pressure conditions. The former corresponds to the typical design condition and the latter to the condition after an outer hull rapture of a tank. Furthermore, two fire scenarios were taken into account: a standard-oriented approach and a hydrocarbon fire-oriented approach. For the study, a test rig was applied that allows testing of TSI at industrial conditions and subsequent analysis of TSI samples. The test rig allows thermal loading and performance analysis of TSI samples at the same time. Comparing the tests, the samples degraded differently. However, no sudden failure of the entire MLI was observed in any test. These results are relevant for the evaluation of incidents with tanks for the storage of cryogenic fluids and can thus contribute to the improvement of TSI and the development of emergency measures for the protection of persons and infrastructures.
Use of higher-alloyed metallic materials and duplex steels for transport tanks of dangerous goods
(2011)
Compatibility evaluations of selected metallic materials under the influence of dangerous goods are published in the BAM-List - Requirements for Tanks for the Transport of Dangerous Goods” as basis for substance-related prototype approvals for tank Containers designed for the carriage of dangerous goods.
There is a request of the tank manufacturing industry and transportation Companies to incorporate additional materials into the BAM-List, especially corrosion-resistant materials because of the large number of corrosive dangerous goods. One solution to solve corrosion Problems is to line the tank with a polymer, an alternative solution is the application of high-alloyed stainless steels and nickel-based alloys as there are 1.4529 (XINiCrMoCu 25-20-7, alloy 926), 1.4562 (X1NiCrMoCu32-28-7, alloy 31) and 2.4605 (NiCr23Mo16AI, alloy 59).
There is an interest to use cost-efficient steels with high strength values and concomitant adequate corrosion resistance such as duplex steel 1.4362 (X2CrNiN23-4).
This steel grade was originally developed as a substitute for the austenitic grades 1.4404 (X2CrNiMo17-12-2) and 1.4571 (X6CrNiMoTi17-12-2). Due to the lower content of the alloy elements nickel and molybdenum this duplex steel is a cost-efficient alternative to molybdenum containing austenite.
Due to the limited number of corrosion test results with welded test samples of these high-alloyed materials and the duplex steel under the influence of corrosive dangerous goods a comprehensive test Programme was performed with these materials in Cooperation with ThyssenKrupp VDM and Deutsche Edelstahlwerke GmbH. It can be concluded from the test results that the superaustenitic steels 1.4529 and 1.4562 as well as the nickel-based alloy 2.4605 are a really good alternative as tank materials for the transport of dangerous goods in comparison to the lining of the tanks. The nickel-based alloy 2.4605 shows the best resistance and is suitable as material for tanks transporting all tested corrosive substances. One exception is the temperature limit during the transport of hydrochloric acid.
The superaustenit 1.4562 is a resistant material with a wide ränge of application. Exceptions for use are: ammonium bifluoride, brine, 34 % calcium Chloride solution, hydrochloric acid, perchloric acid, 90 % 2-chloropropionic acid, nitrating acid with nitric acid content > 50 % and molten monochloroacetic acid. The alloy is limited suitable for allyl Chloride, aluminum Chloride, copper (II) -Chloride and ferric Chloride. The superaustenit 1.4529 showed the lowest resistance compared to the other two materials. This steel is not resistant in hydrochloric acid, perchloric acid, sodium Chlorite and sodium hypochlorite. The application is limited in the concentration ränge of aqueous Solutions of aluminum Chloride, copper (II) Chloride and ferric Chloride. Due to the reduced alloying content of the duplex steel 1.4362 (X2CrNiN23-4) compared to the austenitic CrNiMo-steels, a lower resistance especially in acidic media like formic, acetic or sulfuric acid was observed. Within the more than 7.000 substances contained in the BAM-List there is a large amount of dangerous goods such as hydrocarbons, alcohols, aldehydes, ketones, ethers, esters, and inorganic alkaline substances which have a large transport volume and do not corrode the duplex steel 1.4362 (X2CrNiN23-4).
The test results are included in the actual 11th edition of the BAM-List and therefore available for the costumer.
Biofuels, particularly biodiesel, have gained significant attention as an alternative to traditional fossil fuels in recent years. Unlike diesel, which contains hundreds of compounds, biodiesel only contains a few compounds in the C16-C18 carbon chain. However, the use of biodiesel in automobile and transportation applications can result in problems of degradation or even damage in materials. Among the commonly used polymer materials, fluorocarbon (FKM) shows excellent performance and high stability and compatibility towards oil, diesel, ethanol, and other chemicals. FKM is a family of fluorocarbon-based fluoroelastomer materials, which provide excellent high-temperature and chemical stability compared to other elastomers. As a result, FKM is widely used in chemical processes such as petroleum refining, where it is used for sealings, pumps, and other components.
Mechanical stress often accelerates the failure of polymer materials. The aim of this research is to study the interaction between the sealing material FKM and biofuels B10 (heating oil with 10% biodiesel). The mechanical stress test was carried out in a special apparatus. Both mechanical and non-mechanical stress tests were conducted on specimens at 20, 40, and 70 °C for 28 days to document changes in mass, volume, and tensile properties. Both increasing temperature and mechanical stress have a significant effect on the tensile strength of the FKM polymer when exposed to B10. The combination of increasing temperature and mechanical stress induced rupture within 2 h. It was also established that FKM polymer with pre-exposure in B10 survived longer during mechanical stress compared to specimens exposed only to air. With the support of infrared (IR) spectroscopy, we were able to confirm the penetration of B10 into the FKM polymer.