Filtern
Erscheinungsjahr
Dokumenttyp
Referierte Publikation
- ja (20) (entfernen)
Schlagworte
- Emission test chamber (6)
- VOC (4)
- Volatile organic compounds (3)
- Photocatalysis (2)
- Reference material (2)
- SVOC (2)
- Thermal desorption (2)
- 3D printer (1)
- Accuracy (1)
- AgBB (1)
Organisationseinheit der BAM
Paper des Monats
- ja (1)
Emissions of volatile organic compounds (VOC) and semivolatile organic compounds (SVOC) from materials for flooring installation (primer, screed, adhesive, floor covering) were measured by means of emission test chambers and cells over a time period of at least 28 days at 23 °C, 50% relative humidity and an area specific air flow rate of q = 1.25 m3/m2 h. Single components were tested in comparison to three complete structures (same concrete, primer, screed, adhesive) with different types of floor covering (PVC, carpet, linoleum). Sorption into concrete/screed and different permeability of flooring materials affected the emissions from the complete structures. The complete structures with linoleum and PVC showed the same types of emission and emission rates as the individual floor coverings themselves. Emissions from the carpet-covered structure resulted also from the lower layers. In all cases emissions from the complete structures were lower than the sum of emissions from the single components. For two adhesives the formation of secondary emissions (aldehydes and organic acids) was observed starting after the standard testing time of 28 days.
Background to the studies was the revision of the current selection criteria of the German ecolabel Blauer Engel (Blue angel) for copiers and printers. In the requirements limits were set for ozone, dust and styrene emissions. The former test methods did no longer correspond to todays requirements with regard to emission measurements. In addition, the emission behaviour of hardcopy devices due to the use of different and non-com parable test methods has been recently discussed controversely. For this reason a new test method had to be developed which enables a reliable, reproducible determination of emission rates (ER) for dust, ozone and VOC (volatile organic compounds). The basis for this was the ECMA-Standard 328 compiled by ECMA (European Computer Manufacturer Association) using dynamic chamber measurements. Nine different machines, desktop laser printers as well as office devices like bigger copiers and multifunctional devices were investigated. As a result of the study new criteria for the Blauer Engel for copiers, printers and a new created for multifunctional devices, concerning TVOC, ozone and dust emission were determined. Additionally a model is presented calculating the concentrations in real rooms under usual printing conditions derived from the test chamber results.
Vor dem Hintergrund der notwendigen Revision der Kriterien zur Vergabe des Gütezeichens "Blauer Engel" für Laserdrucker, Kopierer und Multifunktionsgeräte mussten auch die Prüfmethoden angepasst werden, da die alten Verfahren nicht mehr die heutigen Anforderungen der Emissionsmessung erfüllen. In diesem Zusammenhang wurde auch das unterschiedliche Emissionsverhalten von Hardcopy-Geräten auf Grund der verschiedenen und nicht miteinander vergleichbaren Prüfverfahren heftig diskutiert. Aus diesen Gründen wurde ein neues Prüfverfahren entwickelt, mit dem eine verlässliche und reproduzierbare Prüfung der Emissionsraten von Staub, Ozon und flüchtiger organischer Verbindungen auf der Basis des ECMA (European Computer Manufacturer Association) Standards 328 möglich ist. Dazu wurden neun verschiedene Geräte unter verschiedenen Bedingungen untersucht. Als ein Ergebnis dieser Studie wurden neue Kriterien zur Vergabe des "Blauen Engels" für Kopierer, Drucker und Multifunktionsgeräte festgelegt.
A method for the determination of very volatile organic compounds (VVOC) in air was developed and successfully tested for methanol and ethanol. Carbotrap 300 (R) (a multi-bed tube using Carbopack C (R), Carbopack B (R) and Carbosive SIII (R)) was selected as sorption material for thermal desorption and tested for its suitability for emission test chamber measurements. The adsorption behaviour and the chromatographic results are influenced negatively by spiking aqueous solutions on the adsorption medium for calibration purposes. The latter effect can be reduced by blowing dry air across the adsorbent to remove the adsorbed water. Detection and quantification limits were determined for a GC-FID system and compared to GC-MS. The applicability of the method was tested with a methanol eliminating silane modified polymeric adhesive (SMP-adhesive for parquet) in an emission test chamber.
Emission testing of products is currently a rapidly increasing field of measurement activity. Labelling procedures for construction products are based on such emission test chamber measurements and hence measurement performance should be verified. A suited procedure for this purpose is the testing of one unique homogenous material in different laboratories within a Round Robin Test (RRT). Therefore, it is useful to have a reference material which can be used within inter-laboratory studies or as part of the quality management system to ensure comparable results. Several approaches on the development of reproducibly emitting materials have been published. These have in common only to emit a single VOC – toluene. Two further research studies carried out by BAM aimed to develop reference material for emissions testing containing one or more VOC in a single material. The first approach was a doped lacquer with Volatile and Semi-Volatile Organic Compounds (VOC/SVOC) and the second was Thermoplastic Polyurethane (TPU) or a Squalane/Paraffin mixture. Results received with the lacquer based material were presented in more detail.
3D-printing or additive manufacturing has many promising and unique advantages. Especially low cost molten polymer Deposition Printers are increasingly populär in the private and educational sector.
Their environmental friendliness can be questioned due to recently reported ultrafine particle and suspected VOC emissions, To further investigate 3D-printing as a potential indoor air pollution source we characterized fine and ultrafine particle emissions from a molten polymer deposition printer producing a 3D object with ten marketable polymer filament materials under controlled conditions in a test chamber. VOC emissions from the filaments have also been compared. Using a straightforward emission model time dependent and averaged particle emission rates were determined. The results indicate that under comparable conditions some filament materials produce mainly ultrafine particles up to an average rate of 1013 per minute. This value is in the upper ränge of typical indoor ultrafine particle sources (e.g. Smoking, frying, candle light, laser printer). The observed material-specific rates differ by five Orders of magnitude. Filament-specific gaseous emissions of organic compounds such as bisphenol A, styrene and others were also detected.
Our results suggest a detailed evaluation of related risks and considering protective measures such as housing and filtering.
A method for the determination of very volatile organic compounds (VVOC) in air was developed and successfully tested for methanol and ethanol. Carbotrap300® (a multi-bed tube using Carbopack C®, Carbopack B® and Carbosive SIII®) was selected as sorption material for thermal desorption and tested for its suitability for emission test chamber measurements. The adsorption behaviour and the chromatographic results are influenced negatively by spiking aqueous solutions on the adsorption medium for calibration purposes. The latter effect can be reduced by blowing dry air across the adsorbent to remove the adsorbed water. Detection and quantification limits were determined for a GC-FID system and compared to GC-MS. The applicability of the method was tested with a methanol eliminating silane modified polymeric adhesive (SMP-adhesive for parquet) in an emission test chamber