The degree of equivalence within the participating national metrology institutes for the measurement results of the mass fractions of the analytes Cr, Cu, Fe, Mn and Zn in an aluminium alloy was assessed. This interlaboratory comité consultatif pour la quantité de matière key comparison (CCQM-K42) was organised as an activity of the Inorganic Analytical Working Group of CCQM. In total seven laboratories participated, six of them for all analytes. Measurands were the mass fractions of the analytes in a range of 0.05 and 0.2%. As an outcome the consistency of the results for all elements investigated was acceptable, hence satisfactory comparability was established. An aluminium based certified reference material—undisclosed to the analysts which one it was—was used as test sample. For the purpose of this study homogeneity was tested at BAM. Each laboratory was free to choose any analytical method they wanted to use for the analysis. Consequently various methods of measurement were employed: instrumental neutron activation analysis, X-ray fluorescence spectrometry (XRF) using fused cast-bead method combined with reconstitution technique, inductively coupled plasma optical emission spectrometry (ICP OES) and inductively coupled plasma mass spectrometry. Metrological traceability of the measurement results to the SI unit had to be demonstrated. Therefore, methods such as spark OES or XRF (without fused cast-bead technique)—both of them being most important methods for the analysis of metals and alloys in industrial laboratories—could not be used in the frame of the key comparison.
Elastomer seals are widely used as barrier seals in containers for low and intermediate level radioactive waste and in some countries for spent fuel transportation casks. Depending on the area of use, the rubber materials have to demonstrate proper sealing performance with regard to mechanical, thermal and environmental conditions as well as irradiation during the entire operation period.
In Germany the low and intermediate level radioactive waste is planned to be disposed in the Konrad repository in standardized containers. Many of these containers use an elastomer seal between lid and container body. Depending on the radiactive inventory and a possible containment of the waste in inner barrels and/or concrete structures, such containers may require a specific leak tightness. In such cases, specified leakage rates are shall not be exceeded by the the seals to keep potential activity releases from the inventories well below defined limits.
Generally, all waste containers have to fulfill the waste acceptance criteria for the Konrad repository as defined by the reports BfS SE-IB-29/08 and SE-IB-30/08. From these criteria several requirements for seal performance are derived. The seals have to:
- ensure full functionality until final container disposal,
- maintain its function in case of a thermal or mechanical accident,
- ensure encapsulation also at -20 °C.
This combination of requirements is challenging especially as a seal exchange, which is typical for many other applications, is hardly possible and thus a sound understanding of how to perform safety evaluation of containers is required. Therefore BAM has initiated investigations on elastomer seal behaviour. This work focuses on low temperature behaviour and sealing performance concerning static conditions as well as partial loss of compression and ageing of elastomer seals. Concerning ageing, property changes caused by long-term thermooxidative conditions as well as gamma irradiation are investigated.
This contribution presents an overview and explanation of the aims of the ongoing research and gives an update of the most relevant results.