Filtern
Dokumenttyp
- Beitrag zu einem Tagungsband (3)
- Vortrag (3)
- Posterpräsentation (1)
Schlagworte
- Environmental monitoring (7) (entfernen)
Organisationseinheit der BAM
Eingeladener Vortrag
- nein (3)
Gas distribution mapping (GDM) is a valuable tool for monitoring the distribution of gases in various applications, including environmental monitoring, emergency response, and industrial safety. While GDM is actively researched in the scope of gas-sensitive mobile robots (Mobile Robot Olfaction), there is a potential for broader applications utilizing sensor networks. This presentation gives an overview of the different approaches to GDM and motivate the use of a deep-neural network-based approach. As access to ground truth representations of gas distributions remains a challenge in GDM research, an approach for the simulation of realistic-shaped synthetic gas plumes is described, which was used for training Gas Distribution Decoder, a deep neural network for spatial interpolation of spatially sparse gas measurements.
Setting up sensors for the purpose of environmental monitoring should be a matter of days, but often drags over weeks or even months, preventing scientists from doing real research. Additionally, the newly developed hardware and software solutions are often reinventing existing wheels. In this short paper, we revisit the design of our environmental sensing node that has been monitoring industrial areas over a span of two years. We share our findings and lessons learned. Based on this, we outline how a new generation of sensing node(s) can look like.
Setting up sensors for the purpose of environmental monitoring should be a matter of days, but often drags over weeks or even months, preventing scientists from doing real research. Additionally, the newly developed hardware and software solutions are often reinventing existing wheels. In this short paper, we revisit the design of our environmental sensing node that has been monitoring industrial areas over a span of two years. We share our findings and lessons learned. Based on this, we outline how a new generation of sensing node(s) can look like.
Wireless sensor networks provide occupational health experts with valuable information about the distribution of air pollutants in an environment. However, especially low-cost sensors may produce faulty measurements or fail completely. Consequently, not only spatial coverage but also redundancy should be a design criterion for the deployment of a sensor network. For a sensor network deployed in a steel factory, we analyze the correlations between sensors and build machine learning forecasting models, to investigate how well the sensor network can compensate for the outage of sensors. While our results show promising prediction quality of the models, they also indicate the presence of spatially very limited events. We, therefore, conclude that initial measurements with, e.g., mobile units, could help to identify important locations to design redundant sensor networks.
Sensors can fail. Redundancy should therefore be a design driver of wireless sensor networks. For a sensor network deployed in a steel factory, we analyze the correlations between sensors and build machine learning forecasting models, to investigate how well the network can compensate for the outage of sensors.
Development of a Low-Cost Sensing Node with Active Ventilation Fan for Air Pollution Monitoring
(2021)
A fully designed low-cost sensing node for air pollution monitoring and calibration results for several low-cost gas sensors are presented. As the state of the art is lacking information on the importance of an active ventilation system, the effect of an active fan is compared to the passive ventilation of a lamellar structured casing. Measurements obtained in an urban outdoor environment show that readings of the low-cost dust sensor (Sharp GP2Y1010AU0F) are distorted by the active ventilation system. While this behavior requires further research, a correlation with temperature and humidity inside the node shown.
Development of a Low-Cost Sensing Node with Active Ventilation Fan for Air Pollution Monitoring
(2021)
A fully designed low-cost sensing node for air pollution monitoring and calibration results for several low-cost gas sensors are presented. As the state of the art is lacking information on the importance of an active ventilation system, the effect of an active fan is compared to the passive ventilation of a lamellar structured casing. Measurements obtained in an urban outdoor environment show that readings of the low-cost dust sensor (Sharp GP2Y1010AU0F) are distorted by the active ventilation system. While this behavior requires further research, a correlation with temperature and humidity inside the node shown.