Measurement of changes of pH at various intracellular compartments has potential to solve questions concerning the processing of endocytosed material, regulation of the acidification process, and also acidification of vesicles destined for exocytosis. To monitor these events, the nanosized optical pH probes need to provide ratiometric signals in the optically transparent biological window, target to all relevant intracellular compartments, and to facilitate imaging at subcellular resolution without interference from the biological matrix. To meet these criteria we sensitize the surface conjugated pH sensitive indicator via an upconversion process utilizing an energy transfer from the nanoparticle to the indicator. Live cells were imaged with a scanning confocal microscope equipped with a low-energy 980 nm laser excitation, which facilitated high resolution and penetration depth into the specimen, and low phototoxicity needed for long-term imaging. Our upconversion nanoparticle resonance energy transfer based sensor with polyethylenimine-coating provides high colloidal stability, enhanced cellular uptake, and distribution across cellular compartments. This distribution was modulated with membrane integrity perturbing treatment that resulted into total loss of lysosomal compartments and a dramatic pH shift of endosomal compartments. These nanoprobes are well suited for detection of pH changes in in vitro models with high biological background fluorescence and in in vivo applications, e.g., for the bioimaging of small animal models.
Online (passive) thermographic inspection of overlap joints of aluminium and zinc coated steel sheets made by cold metal Transfer weld brazing process was explored. Different experimental Trials were conducted for demonstrating the feasibility of thermographic inspection to detect the porosities, improper weld bead and to differentiate the pre weld temperature. The whole process was monitored using infrared cameras in different wavelength region.
Image analysis algorithms were developed to reconstruct the thermal images that contain the signatures of the weld defects and to extract the pre weld temperature and ist evolution with distance from the centre of the weld torch. Post-weld radiography lends strong Support to the observations.
In this study, the feasibility of using non-contact Infrared thermography as a potential tool to monitor the CMT welding process is explored. The presence of internal defects such as porosity, lack of filler material deposition and formation of improper weld bead produce perturbations in the surface temperature which can be identified using an Infrared thermography technique. We present recent results obtained from online monitoring of the the dissimilar joining using CMT weld brazing of Aluminum and Steel using a transmission mode measurement approach. The effect of loss of zinc coating on the weldability of the cold metal transfer joining of aluminum to galvanised steel was investigated. A correlation between measured online thermal indications with the weld anomalies is successfully attempted and the results are compared with the conventional post-weld NDT inspection methods.
Cancer is a severe disease characterized by high mortality and complex pathophysiology; however, its early and accurate diagnosis remains inadequate. Conventional diagnostic approaches often fall short, particularly for dense tissues, and are frequently invasive, costly, and of limited availability. This reinforces the need for a compact, economical, and ultrasensitive assay that is operationally simple and interpretable.
We present an efficient electrochemical detection platform for the cancer biomarker mucin 1 (MUC1). A fluorine-doped tin oxide (FTO) surface was modified with an iron-based metal–organic framework (FeMOF) intercalated with palladium nanorods (PdNR). FeMOF was prepared using Fe3+/Fe2+ precursors at a 1.2/1 mmol ratio and dual ligands, i.e. tetrahydroxy-1,4-benzoquinone and 2-aminobenzene-1,4-dicarboxylic acid. AntiMUC1 antibodies were immobilized on a modified electrode via p-phenylenediamine (PDA) (FTO/FeMOF@PdNR/PDA/antiMUC1Ab) and evaluated using electrochemical impedance spectroscopy (EIS) and voltammetry. The designed sensor demonstrated an excellent binding affinity for the MUC1 antigen. Among these techniques, the EIS method stands out for its technical performance, as evidenced by the high sensitivity (detection limit 0.074 fg mL−1), quantification limit 0.24 fg mL−1, and high analytical sensitivity (1.39 × 103 Ω fg−1 mL−1 cm−2). The negligible cross-reactivity with interferent biomolecules, rapid response (10-minute equilibrium), regenerability up to 5 cycles, high reproducibility (RSD ∼1–3%), and long-term stability (up to 35 days) further validate the suitability of the proposed MUC1 immunosensor. This study presents an ultrasensitive biosensor that is compact, cost-effective, and easy for individuals at home to use after further development into a kit-based end product. Moreover, its excellent functionality for spiked serum samples shows promise for next-generation clinical diagnostics.