Test strips that in combination with a portable fluorescence reader or digital camera can rapidly and selectively detect chemical warfare agents (CWAs) such as Tabun (GA), Sarin (GB), and Soman (GD) and their simulants in the gas phase have been developed. The strips contain spots of a hybrid indicator material consisting of a fluorescent BODIPY indicator covalently anchored into the channels of mesoporous SBA silica microparticles. The fluorescence quenching response allows the sensitive detection of CWAs in the μg m−3 range in a few seconds.
A novel mesoporous silica material containing boron–dipyrromethene (BODIPY) moieties (I) is employed for the detection of nerve agent simulants (NASs) and the organophosphate nerve or chemical warfare agents (CWAs) Sarin (GB), Soman (GD), and Tabun (GA) in aqueous environments. The reactive BODIPY dye with an optimum positioned hydroxyl group undergoes acylation reactions with phosph(on)ate substrates, yielding a bicyclic ring. Due to aggregation of the dyes in water, the sensitivity of the free dye in solution is very low. Only after immobilization of the BODIPY moieties into the silica substrates is aggregation inhibited and a sensitive determination of the NASs diethyl cyanophosphonate (DCNP), diethyl chlorophosphate (DCP) and diisopropyl fluorophosphate (DFP) possible. The signaling mode is a strong quenching of the fluorescence, reaching LODs in the pM range. The best performing hybrid material was singled out from a library of hybrid silicas varying in morphology and surface functionalization. The response to actual CWAs such as GB, GD, and GA has also been tested, offering similar behavior as for the simulants. The proposed reaction mechanism has been verified by investigation of other model materials, containing for instance BODIPY moieties without an optimum hydroxyl group (III) or a BODIPY dye with an all-aliphatic counterpart (IV). The latter can only form a monocyclic reaction product, showing much less reactivity as I. Assays with other possible competitors have been additionally carried out, showing favorably low cross-reactivities. Finally, the determination of NASs in several natural waters has been demonstrated.
With the help of the EXIST research transfer the startup True Detection System (TDS) will develop a portable and easy-to-use handheld device based on chemical-optical sensors that can detect the smallest traces of various explosives and markers (e.g. TNT, C4, ANFO, TATP, DMDNB, etc.) and pure salts (e.g. potassium nitrate) reliably and without major cross-sensitivities. The device has been developed over the last 10 years at the Federal Institute for Material Research and Testing (BAM) in cooperation with an SME. Within the next 18 months, a laboratory prototype will now be converted into a commercial device.
The development of a Lab-on-a-Chip (LoC) is presented, which can detect reactive phosphorous compounds in the gas phase in combination with an optochemical hand-held sensor. The LoC prototype contains three pairs of sensing materials containing fluorescent indicator dyes in various carrier materials. By measuring the fluorescence response to phosphoryl chloride, a surrogate compound, the detection of chemical warfare agents (CWAs) in gas phase becomes possible within seconds, introducing a novel approach to CWA detection.
An improved antibody against the explosive pentaerythritol tetranitrate (PETN) was developed. The immunogen was designed by the concept of bioisosteric replacement, which led to an excellent polyclonal antibody with extreme selectivity and immunoassays of very good sensitivity. Compounds such as nitroglycerine, 2,4,6-trinitrotoluene, 1,3,5-trinitrobenzene, hexogen (RDX), 2,4,6-trinitroaniline, 1,3-dinitrobenzene, octogen (HMX), triacetone triperoxide (TATP), ammonium nitrate, 2,4,6-trinitrophenol and nitrobenzene were tested for potential cross-reactivity. The detection limit of a competitive enzyme-linked immunosorbent assay (ELISA) was determined to be around 0.5 µg/L. The dynamic range of the assay was found to be between 1 µg/L and 1000 µg/L, covering a concentration range of three decades. This work shows the successful application of the bioisosteric concept in immunochemistry by exchange of a nitroester to a carbonate diester. The antiserum might be used for the development of quick tests, biosensors, microtitration plate immunoassays, microarrays and other analytical methods for the highly sensitive detection of PETN, an explosive frequently used by terrorists, exploiting the extreme difficulty of its detection.
The globe's seas were used as dumping ground after the world wars and those millions of ammunition, most of all containing 2,4,6-trinitrotoluene (TNT), represent a pressing danger for fishermen, dredging operations, submarine cable installations and tourism. We developed an extremely selective indication method for TNT based on a specific reaction that produces a highly fluorescent compound. The indication system was integrated into a microfluidic PDMS chip for the solid-liquid extraction of TNT from water samples, offering environmental monitoring possibilities. Combining the advantages of a light-up indicator, microfluidics and a smartphone as detector, the embedded sensor allows for the remote and rapid detection of TNT down to ng in surface and sea waters.
Integration of a polymerisable fluorescent urea-nitrobenzoxadiazole monomer 1 into a few-nanometre thin molecularly imprinted polymer (MIP) shell coated onto a 300 nm silica core with the tetrabutylammonium salt of N-carbobenzyloxy-L-phenylalanine (Cbz- or Z-ʟ-Phe) as the imprinted template yields core/shell MIP nanoparticles that respond to the designated analyte with a strong fluorescence increase in the visible spectral range. The system shows promising imprinting and enantioselectivity factors of 3.6 and 1.9 when benzylmethylacrylate (BMA) is used as co-monomer and ethylene glycol dimethacrylate (EDMA) as cross-linker. A second, naphthalimide-based fluorescent urea 2 is employed in the preparation of MIP thin-films and monolithic polymers for separation techniques. Spectroscopic and chromatographic studies of the MIPs with the analytes Z-ʟ-Phe, Z-ʟ-glutamic acid (Z-ʟ-Glu) and penicilin G (PenG) revealed the (enantio)selective discrimination behaviour of these materials.
Gated hybrid delivery systems: En route to sensory materials with inherent signal amplification
(2013)
Hybrid nanoparticles with a large specific surface area are a particularly exciting vehicle for delivery applications. Such highly porous or container-like structures, usually prepared from silica and frequently from gold, can incorporate a large number of chemical substances such as drug and/or indicator molecules. When equipped with a chemically or physically addressable gating function at the openings of the voids, the release of the cargo can be controlled at will. Because many more molecules can be stored as cargo in the pores of the support than there are functional groups as anchoring sites for the gating entities attached to the outer surface (for efficient pore capping), the systems possess inherent features of (signal) amplification. The present article will introduce various design strategies for different types of physical (light, temperature, magnetism) and chemical (pH, metal ions, anion, small organic molecules, enzymes) stimuli in connection with drug and indicator release. We will highlight exciting aspects of combining both features in theranostic applications and will stress which requirements still have to be met by many of the systems to be readily applicable in a sensory context.
Fluorescent sensory MIP (molecularly imprinted polymer) particles were combined with a droplet-based 3D microfluidic system for the selective determination of a prototype small-molecule analyte of environmental concern, 2,4-dichlorophenoxyacetic acid or 2,4-D, at nanomolar concentration directly in water samples. A tailor-made fluorescent indicator cross-linker was thus designed that translates the binding event directly into an enhanced fluorescence signal. The phenoxazinone-type cross-linker was co-polymerized into a thin MIP layer grafted from the surface of silica microparticles following a RAFT (reversible addition-fragmentation chain transfer) polymerization protocol. While the indicator cross-linker outperformed its corresponding monomer twin, establishment of a phase-transfer protocol was essential to guarantee that the hydrogen bond-mediated signalling mechanism between the urea binding site on the indicator cross-linker and the carboxylate group of the analyte was still operative upon real sample analysis. The latter was achieved by integration of the fluorescent core-shell MIP sensor particles into a modular microfluidic platform that allows for an in-line phasetransfer assay, extracting the analyte from aqueous sample droplets into the organic phase that contains the sensor particles. Real-time fluorescence determination of 2,4-D down to 20 nM was realized with the system and applied for the analysis of various surface water samples collected from different parts of the world.