The transport of peracetic acid (PAA) in intermediate bulk containers (IBC) and tanks is only possible if they have suitable pressure relief devices. To determine the dimension of the pressure relief devices the 10-l-model tank of annex 5 of the UN Manual of Tests and Criteria is used.
During the investigation of a PAA this model tank fragmented. To prevent such violent events in the future, the model tank should be provided with additional pressure relief devices.
Deflagration tests were conducted with two kinds of autoclaves. Parameter studies were carried out concerning the gas atmosphere and substances used. Deflagration tests were performed in different pressure regions. Furthermore, deflagration test results of different substances were compared to the corresponding DSC results. Previous findings concerning vacuum conditions could be approved for a greater range of substances. In addition, investigations in nitrogen atmosphere were performed in order to investigate the deflagration behaviour. Experiments up to 161 bar could be utilized. An acceleration of deflagration velocity with increasing pressure was observed in a large pressure interval.
Azodicarbonamid (ADCA) ist ein bekanntermaßen deflagrationsfähiger Stoff, der in der Kunststoffindustrie als Treib- und Blähmittel eingesetzt wird. In diesem Beitrag wird die Deflagration von ADCA unter verschiedenen Bedingungen betrachtet. Es werden Ergebnisse von Experimenten in offenen und geschlossenen Systemen präsentiert. In geschlossenen Systemen wurde die Zusammensetzung der umgebenden Atmosphäre von Luft mit Umgebungsdruck über Luft mit Unter- und Überdruck hin zu Stickstoff mit Umgebungsdruck variiert. Um das Deflagrationsrisiko zu reduzieren wird eine Verarbeitung von ADCA im Vakuum vorgeschlagen.
The thermal decomposition of dicumyl peroxide dissolved in ethylbenzene has been studied in our laboratories using differential scanning calorimetry (DSC), calvet calorimetry (C80), adiabatic calorimetry, reaction calorimetry and micro calorimetry.
Based on the DSC and C80 experiments a formal kinetics model has been derived, which was compared to the other applied techniques. Finally we used our model to predict the thermal response of 216.5 L steel drums to exposure to constant elevated temperatures, both using the stationary Semenov approach as well as time-resolved CFD simulations. The prediction was compared to one-to-one testing using the UN-Test H.1. The observed level of consistency between model and experiments is remarkably good. The comparison with the 216.5 L testing clearly demonstrates that reliable and conservative predictions for technically relevant scales are possible as long as a validated model is used.
Bei der Bewertung der Verlässlichkeit der im Labor gewonnenen Prüfergebnisse spielen Ringversuche eine entscheidende Rolle. Die Bundesanstalt für Materialforschung und -prüfung (BAM) unterstützt deshalb den weiteren Ausbau des Ringversuchsprogramms des im Jahr 2007 gegründeten Kompetenzzentrums zur Qualitätssicherung für Prüfungen von Gefahrgütern und Gefahrstoffen auf physikalische Gefahren (Centre for quality assurance for testing of dangerous goods and hazardous substances, CEQAT-DGHS).
Bei allen bisher untersuchten Prüfmethoden besteht ein Verbesserungsbedarf. Die RV müssen daher zunächst auf die Methodenentwicklung, -verbesserung und -validierung abzielen und nicht auf Leistungstests.