Filtern
Erscheinungsjahr
Dokumenttyp
- Vortrag (142)
- Zeitschriftenartikel (77)
- Beitrag zu einem Tagungsband (35)
- Posterpräsentation (12)
- Buchkapitel (6)
- Forschungsbericht (4)
- Sonstiges (3)
- Beitrag zu einem Sammelband (2)
- Forschungsdatensatz (2)
- Monografie (1)
Sprache
- Deutsch (151)
- Englisch (134)
- Mehrsprachig (1)
Schlagworte
- Prozessanalytik (59)
- Online NMR Spectroscopy (36)
- Process Analytical Technology (36)
- Industrie 4.0 (34)
- Prozessindustrie (34)
- CONSENS (29)
- Process analytical technology (24)
- Online NMR spectroscopy (21)
- Reaction Monitoring (17)
- Digitalisierung (16)
- qNMR (15)
- Indirect Hard Modeling (14)
- Smart Sensors (14)
- Automation (13)
- Online-NMR-Spektroskopie (13)
- Process Industry (13)
- Process Monitoring (13)
- Prozess-Sensoren 4.0 (13)
- Industry 4.0 (12)
- Reaction monitoring (12)
- Smarte Sensoren (12)
- Prozess-Sensoren (10)
- Sensoren (10)
- Modular Production (9)
- Process Control (9)
- Quantitative NMR Spectroscopy (9)
- Indirect hard modeling (8)
- Quantitative NMR-Spektroskopie (8)
- Datenanalyse (7)
- Process control (7)
- Roadmap (7)
- Automatisierung (6)
- Data Analysis (6)
- Digitale Transformation (6)
- NAMUR (6)
- NMR (6)
- Prozess-Spektroskopie (6)
- Raman spectroscopy (6)
- Chemometrics (5)
- Digitalisation (5)
- Hydroformylation (5)
- Raman-Spektroskopie (5)
- Hydrogen Storage (4)
- Online NMR (4)
- Process industry (4)
- Quantitative NMR spectroscopy (4)
- Sensorik (4)
- Artificial Neural Networks (3)
- Artificial neural networks (3)
- Benchtop NMR spectroscopy (3)
- Click Chemistry (3)
- Continuous Manufacturing (3)
- Data processing (3)
- Datenkonzepte (3)
- Digital Transformatioin (3)
- Digital transformation (3)
- Digitization (3)
- EuroPACT (3)
- Gas analysis (3)
- H2Safety@BAM (3)
- Low-field NMR spectroscopy (3)
- Medium-resolution NMR (3)
- MefHySto (3)
- Metrologie (3)
- Metrology (3)
- Mini-plant (3)
- NMR Spectroscopy (3)
- NMR spectroscopy (3)
- NMR-Spektroskopie (3)
- Normung (3)
- Partial least squares regression (3)
- Process monitoring (3)
- Prozesskontrolle (3)
- Quantitative NMR (3)
- Real-time process monitoring (3)
- Referenzmaterialien (3)
- SMASH (3)
- Smart sensors (3)
- Smarte Feldgeräte (3)
- Spectral Modeling (3)
- Wasserstoff (3)
- 19F (2)
- 1H (2)
- Absorption (2)
- Analytik (2)
- Benchtop NMR Spectroscopy (2)
- Chemometrie (2)
- Cocrystals (2)
- Cokristalle (2)
- Cyber-Physical Systems (2)
- Datenauswertung (2)
- Datenvorbehandlung (2)
- Digital Transformation (2)
- Direct purity determination (2)
- Distributed Networks (2)
- EMPIR (2)
- Gasanalytik (2)
- Gassensorik (2)
- Hydroformylierung (2)
- Hydrogen (2)
- IHM (2)
- Indirect Hard Modelling (2)
- Innovationen (2)
- Kommunikation (2)
- LIBS (2)
- Lab of the Future (2)
- Laboratory 4.0 (2)
- Low-field NMR Spectroscopy (2)
- M+O-Sensoren (2)
- Mass Spectrometry (2)
- Mechanochemistry (2)
- Medium-Resolution-NMR-Spektroskopie (2)
- Messunsicherheit (2)
- Metal−organic frameworks (2)
- Microemulsions (2)
- NAMUR Open Architecture (2)
- NMR Validation (2)
- NMR validation (2)
- NOA (2)
- Nuclear Magnetic Resonance Spectroscopy (2)
- OPC-UA (2)
- Online (2)
- Online NMR Spektroskopie (2)
- Online monitoring (2)
- PANIC (2)
- PLS-R (2)
- Partial Least Squares Regression (2)
- Pharmazeutische Produktion (2)
- Process sensors (2)
- Purity (2)
- QI-Digital (2)
- Quality Infrastructure (2)
- Quantitative Online-NMR-Spektroskopie (2)
- Reaktionsmonitoring (2)
- Reference Material (2)
- Sensors (2)
- Smarte Aktoren (2)
- Smarter Sensor (2)
- Specialty Chemicals (2)
- ZVEI (2)
- qNMR Summit (2)
- 19F-NMR (1)
- 1H-NMR (1)
- ANAKON (1)
- Abgas (1)
- Accreditation (1)
- Advanced process control (1)
- Aktorik (1)
- Amine (1)
- Analytical Sciences (1)
- Analytical science (1)
- Applikationslabor (1)
- Atomic and molecular physics, and optics (1)
- Auflösungskinetik (1)
- Auflösungsverhalten (1)
- Automated Data Evaluation (1)
- Autonomous chemistry (1)
- BAM (1)
- BONARES (1)
- Basic Statistics (1)
- Baustoffe (1)
- Benchtop NMR (1)
- Betriebspunktoptimierung (1)
- Big Data (1)
- Big science (1)
- Bio engineering (1)
- BioProScale (1)
- Bioprozess (1)
- Biotechnology (1)
- Bonares (1)
- CCQM-K (1)
- CCQM-K101 (1)
- CCS (1)
- CFD (1)
- CO2 (1)
- CO2-Absorption (1)
- CRDS (1)
- Carbamazepine (1)
- Carbon capture (1)
- Carbon dioxide (1)
- Catalysis (1)
- Certified reference materials (1)
- Chemical Process Control (1)
- Chemical processes (1)
- Chemometrik (1)
- Clean energy technology (1)
- Climate change (1)
- Compact NMR (1)
- Compact NMR Spectroscopy (1)
- Comparison study (1)
- Competence Center (1)
- Continuous Processes (1)
- Continuous processes (1)
- Croyo-starage (1)
- Cryoadsorption (1)
- Cyber-physical Lab (1)
- Cyber-physical Test Labs (1)
- Cyber-physical system (1)
- Cyber-physical systems (1)
- Cyberphysisches Labor (1)
- DEA (1)
- DECHEMA (1)
- DFG (1)
- DFT (1)
- DIN (1)
- Data Fusion (1)
- Data analysis (1)
- Data evaluation (1)
- Database (1)
- Datenbanken (1)
- Datenerfassung (1)
- Dezentrale Netzwerke (1)
- Digital Twin (1)
- Digital Twins (1)
- Digital twins (1)
- Digitaler Zwilling (1)
- Digitalisierung der Prozessindustrie (1)
- Digitization of process industry (1)
- Direct loop control (1)
- Dispersion (1)
- Dissolution (1)
- Dissolution studies (1)
- Druckgasspeicher (1)
- EURAMET.QM-K111 (1)
- Echtzeitoptimierungsverfahren (1)
- Edge Computing (1)
- Editorial (1)
- Education (1)
- Embedded spectroscopy (1)
- Emulsions (1)
- Emuslions (1)
- Encyclopedia of Analytical Chemistry (1)
- Energiespeicherung (1)
- Energy Gases (1)
- Energy production (1)
- Energy storage (1)
- Energy systems (1)
- Erdgas (1)
- Escherichia coli (1)
- EuroPact (1)
- Eurosensors (1)
- Explosionsschutz (1)
- Fake news (1)
- Faseroptik (1)
- Fermentation (1)
- Fibre-optic sensors (1)
- First Principles (1)
- First principles (1)
- Flow Chemistry (1)
- Flow-NMR (1)
- Fluorescence (1)
- Fluoreszenz-Spektroskopie (1)
- Forschungsbedarf (1)
- Forschungslandschaft Wasserstoff (1)
- Fresenius (1)
- Fresenius Lecture (1)
- Fresenius lecture (1)
- GDCh (1)
- Gas Reference Material (1)
- Gas purity (1)
- Gas-Normale (1)
- Gas-phase NMR spectroscopy (1)
- Gasdetektion (1)
- Gasgualität (1)
- Gasreinheit (1)
- Geological Storage (1)
- Gepulste Ramanspektrometer (1)
- Gerätekommunikation (1)
- Glasspeicher (1)
- Grand challenges (1)
- Green Deal (1)
- Handbook (1)
- High-pressure volumetric analyzer (HPVA) (1)
- Hydration (1)
- Hydrogen Fuelling Stations (1)
- Hydrogen Metrology (1)
- Hydrogen Purity (1)
- Hydrogen Storage Materials (1)
- Hydrogen Strategy (1)
- Hydrogen adsorption storage (1)
- Hyphenation (1)
- IMS (1)
- ISO 17025 (1)
- ISO/IEC 17025 (1)
- IT-OT-Testplattform (1)
- IUTA (1)
- Imaging (1)
- Imidazole (1)
- Impfstoffe (1)
- In situ Raman (1)
- Indirect Hard Modeling (IHM) (1)
- Industrielle Analytik (1)
- Industry 4.0, (1)
- Informations- und Kommunikationstechnik (1)
- Informationsmanagement (1)
- Infrastruktur (1)
- Inline Analytics (1)
- Inline NMR Spectroscopy (1)
- Instrument Communication (1)
- Instrumentation (1)
- Integrated Processes (1)
- Intelligence for Soil (1)
- Interlaboratory Comparison (1)
- Iterative real-time optimization (1)
- Joung Analysts (1)
- Kernresonanzspektroskopie (1)
- Kohlenstoff-13-NMR-Spektroskopie (1)
- Kommunikation für Analysengeräte (1)
- Kommunikationsstandards (1)
- Konnektivität (1)
- Kristallolgraphie (1)
- Künstliche Intelligenz (1)
- Künstliche Neuronale Netze (1)
- Künstlicher Intelligenz (1)
- Labor 4.0 (1)
- Labor der Zukunft (1)
- Labor-IT (1)
- Labor-Robotik (1)
- Laboratory Information Management System (1)
- Laborautomation (1)
- Laborkommunikation (1)
- Large-scale processing (1)
- Laser-induced Breakdown Spectroscopy (1)
- Lastwechsel (1)
- Lessing (1)
- Limit of Detection (1)
- Linear Regression (1)
- Low field NMR spectroscopy (1)
- Low-Field NMR spectroscopy (1)
- MEA (1)
- MOF´s (1)
- Machine-Assisted Workflows (1)
- Mass spectrometry (1)
- Metabolite quantification (1)
- Metal-organic frameworks (MOFs) (1)
- Micoemulsion (1)
- Micro Reactor (1)
- Microemulsion (1)
- Microplastics (1)
- Mikroemulsionen (1)
- Mikroplastik (1)
- Mini-UAV (1)
- Mizellen (1)
- Model Predictive Control (1)
- Modifier adaptation (1)
- Modifier-Adaptation (1)
- Modular production plants (1)
- Modular production units (1)
- Modulare Produktion (1)
- Multielementanalytik (1)
- Multimodale Analytik (1)
- Multivariate Data Analysis (1)
- Multivariate Datenanalyse (1)
- Multivariate classification (1)
- Multivariate data analysis (1)
- NAMUR Open Architecture (NOA) (1)
- NIR (1)
- NIR Spectroscopy (1)
- NIR spectroscopy (1)
- NMR Accreditation (1)
- NMR Method Validation (1)
- NMR-Durchflussmesszelle (1)
- Nahinfrarot-Spektroskopie (1)
- Nathan der Weise (1)
- Near Infrared Spectroscopy (1)
- Near infrared spectroscopy (1)
- Nitrogen (1)
- Normen (1)
- Nuclear Magnetic Resonance (1)
- Nuclear magnetic resonance spectroscopy (1)
- OPC UA (1)
- On-line technique (1)
- Online NMR Spectrsocopy (1)
- Online Raman Spectroscopy (1)
- Online-NMR-Spektroscopie (1)
- Online-RFA-Spektroskopie (1)
- Online-Raman-Spektroskopie (1)
- Online-spectroscopy (1)
- Optical Spectroscopy (1)
- PAT (1)
- PAT/QbD (1)
- PEM-Wasserelektrolyse (1)
- PLS (1)
- PRORA (1)
- Partikelmesstechnik (1)
- Pharmaceutical Production (1)
- Pharmaceuticals (1)
- Pharmazeutische Cokristalle (1)
- Pharmazeutische Formulierungen (1)
- Pharmazeutische Industrie (1)
- Pharmazeutische Wirkstoffe (1)
- Photonendichtewellen-Spektroskopie (1)
- Physical and theoretical chemistry (1)
- Physical twin (1)
- Pichia pastoris (1)
- Plant-model mismatch (1)
- Polymerisation (1)
- Polymers (1)
- Positionspapier (1)
- Powder X-ray diffraction (1)
- Powder diffraction (1)
- Power-to-Gas (1)
- Pozessindustrie (1)
- Pprocess analytical technology (1)
- Primary reference gas mixtures (1)
- Primary reference material (1)
- Procee Analytical Technology (1)
- Process Analytical Tecnology (1)
- Process analysis (1)
- Process analytical technology (PAT) (1)
- Process analytics (1)
- Process intelligence (1)
- Process sensors 4.0 (1)
- ProcessNet (1)
- Produktqualität (1)
- Propane in nitrogen (1)
- Protonen-NMR-Spektroskopie (1)
- Prouess-Sensoren 4.0 (1)
- Prozess-Steuerung (1)
- Prozessanalysentechnik (1)
- Prozesslabor (1)
- Prozesssensoren (1)
- Prozesssicherheit (1)
- Prozessverfolgung (1)
- Purity Analysis (1)
- Purity analysis (1)
- QNMR (1)
- Quality Assurance (1)
- Quality Management (1)
- Quality by Design (1)
- Quality by design (1)
- Qualitätssicherung (1)
- Quanten-Kaskadenlaser (1)
- Quantification (1)
- Quantum Mechanics (1)
- Quantum mechanics (1)
- RF-Dämpfung (1)
- RFA (1)
- Raman (1)
- Reactor control (1)
- Real time release (1)
- Real-time Process Monitoring (1)
- Real-time quality control (1)
- Recycling (1)
- Reference material (1)
- Regel- und Messtechnik (1)
- Residence time (1)
- Resource Analytics (1)
- Ressourcenanalytik (1)
- Reversible Hydrogen Storage (1)
- Risikoanalyse (1)
- Risk Assessment (1)
- Rückführbarkeit (1)
- Rückverstromung (1)
- SPECTARIS (1)
- Safety (1)
- Salicylic acid (1)
- Salsa (1)
- Salts (1)
- SensRef (1)
- Sensor response (1)
- Smart Laboratoy (1)
- Smart actuators (1)
- Smart test laboratories (1)
- Smarte Laborgeräte (1)
- Smarter Aktor (1)
- Smartes Labor (1)
- Sonderprobenanalytik (1)
- Speciation (1)
- Spectaris (1)
- SsNMR (1)
- Standortvorteil (1)
- Static Mixing (1)
- Statistics (1)
- Statistik (1)
- Summer School (1)
- Surface-enhanced Raman spectroscopy (SERS) (1)
- Sustainable Production (1)
- TDLAS (1)
- TSA (1)
- Technologie-Roadmap (1)
- Technologie-Roadmap "Prozess-Sensoren 4.0" (1)
- Technologie-Roadmap Prozess-Sensoren (1)
- Technologieroadmap (1)
- Technologievisionen (1)
- Technologiewünsche (1)
- Temperature Control (1)
- Terahertz spectroscopy (1)
- Thermal Process Engineering (1)
- Thiol-ene click chemistry (1)
- Time-gated Raman (TG-Raman) (1)
- Time-gated Raman-Spektroskpie (1)
- Trends (1)
- Tribologie (1)
- Troubleshooting Samples Analytics (1)
- Tutzing Symposion (1)
- Tutzing-Symposion (1)
- Twin-screw extrusion (TSE) (1)
- UV/VIS spectroscopy (1)
- Ultraschall (1)
- Uncertainty Evaluation (1)
- Underground gas storage (UGS) (1)
- Verfahrensentwicklung (1)
- Wasserstoff Referenzmaterial (1)
- Wasserstoff-Qualität (1)
- Wasserstoff-Wirtschaft (1)
- Wasserstoffanalytik (1)
- Wasserstofferzeugung (1)
- Wasserstoffspeicher (1)
- Wasserstofftankstelle (1)
- Weighing Uncertainty (1)
- Wissenschaftskultur (1)
- X-ray fluorescence (1)
- ZIF-8 (1)
- Zerstörungsfreie Prüfung (1)
- Zertifikat (1)
- desorption control (1)
- purity (1)
- qNMR metrology (1)
- qNMR-Spektroskopie (1)
- research landscape (1)
- zertifizierte Referenzmaterialien (1)
- “Click” chemistry (1)
Organisationseinheit der BAM
- 1 Analytische Chemie; Referenzmaterialien (119)
- 1.4 Prozessanalytik (118)
- 8 Zerstörungsfreie Prüfung (14)
- 8.6 Faseroptische Sensorik (10)
- 6 Materialchemie (5)
- 8.0 Abteilungsleitung und andere (5)
- 6.3 Strukturanalytik (4)
- 8.1 Sensorik, mess- und prüftechnische Verfahren (4)
- 3 Gefahrgutumschließungen; Energiespeicher (3)
- 1.3 Instrumentelle Analytik (2)
Paper des Monats
- ja (1)
Eingeladener Vortrag
- nein (142)
Chancen der Prozessanalyitk
(2009)
Die Wettbewerbsfähigkeit der Chemisch-Pharmazeutischen Industrie basiert auf der Sicherung der geforderten Produktqualität bei einer optimalen Nutzung von Anlagen, Rohstoffen und Energie. Eine gute Prozessführung unter Einsatz zuverlässiger Prozessautomation sichert hier den globalen Wettbewerbsvorteil. Initiiert von NAMUR und GMA und unter Mitwirkung der Unternehmen ABB, BASF, BTS, BIS Prozesstechnik, E+H, Siemens und der BAM entstand jetzt die grundlegend aktualisierte und überarbeitete Technologie-Roadmap "Prozess-Sensoren 2015+", die im November 2009 veröffentlicht wurde.
Die Sensorik von morgen
(2010)
Eine gleich bleibend effektive Nutzung von Anlagen, Rohstoffen und Energie in Verbindung mit der optimalen Prozessführung sind die wichtigsten Voraussetzungen für globale Wettbewerbsvorteile der Prozessindustrie.
Unternehmen aus den Bereichen Chemie, Pharmazie, Petrochemie, Gasverarbeitung, Lebensmittel-, Zellstoff-, Papier-, Glas-, Stahl- und Zementherstellung sowie ihren Zulieferern haben den Einsatz zuverlässiger Prozessautomation für eine gute Prozessführung erkannt. Überlegene Verfahren stützen sich zunehmend auf prozessanalytische Messtechnik zur Kontrolle und präventiven Sicherstellung der geforderten Produktqualität. Gleichzeitig ermöglicht sie eine ständige Verbesserung des Wissens über den Prozess und erhöhen die Prozess- und Anlagensicherheit.
Prozessanalytik: Konzepte und Strategien Prozessanalytik in Flüssigkeiten (Hardwareüberblick)
(2011)
Vor 100 Jahren, am 22. Mai 1913, erhielt Dr. Paul Gmelin, Mitarbeiter im physikalischen Laboratorium der Badischen Anilin und Soda Fabrik in Ludwigshafen das erste Patent auf ein Prozessanalysenmessgerät. Dieses Jubiläum würdigt CITplus mit diesem Beitrag, in dem die Autoren nicht nur die vergangene sondern auch eine mögliche künftige Entwicklung der Prozessanalysentechnik (PAT) Revue passieren lassen.
Medium resolution nuclear magnetic resonance (MR-NMR) spectroscopy is currently a fast developing field, which has an enormous potential to become an important analytical tool for reaction monitoring, in hyphenated techniques, and for systematic investigations of complex mixtures. The recent developments of innovative MR-NMR spectrometers are therefore remarkable due to their possible applications in quality control, education, and process monitoring. MR-NMR spectroscopy can beneficially be applied for fast, non-invasive, and volume integrating analyses under rough environmental conditions.
Within this study, a simple 1/16'' fluorinated ethylene propylene (FEP) tube with an ID of 0.04'' (1.02 mm) was used as a flow cell in combination with a 5 mm glass Dewar tube inserted into a benchtop MR-NMR spectrometer with a 1H Larmor frequency of 43.32 MHz and 40.68 MHz for 19F. For the first time, quasi-simultaneous proton and fluorine NMR spectra were recorded with a series of alternating 19F and 1H single scan spectra along the reaction time coordinate of a homogeneously catalysed esterification model reaction containing fluorinated compounds. The results were compared to quantitative NMR spectra from a hyphenated 500 MHz online NMR instrument for validation. Automation of handling, pre-processing, and analysis of NMR data becomes increasingly important for process monitoring applications of online NMR spectroscopy and for its technical and practical acceptance. Thus, NMR spectra were automatically baseline corrected and phased using the minimum entropy method. Data analysis schemes were designed such that they are based on simple direct integration or first principle line fitting, with the aim that the analysis directly revealed molar concentrations from the spectra.
Finally, the performance of 1/16'' FEP tube set-up with an ID of 1.02 mm was characterised regarding the limit of detection (LOQ (1H) = 0.335 mol L-1 and LOQ (19F) = 0.130 mol L-1 for trifluoroethanol in D2O (single scan)) and maximum quantitative flow rates up to 0.3 mL min-1. Thus, a series of single scan 19F and 1H NMR spectra acquired with this simple set-up already presents a valuable basis for quantitative reaction monitoring.
In der Forschung wird die Kernspinresonanzspektroskopie (NMR-Spektroskopie von englisch: nuclear magnetic resonance) für die Strukturaufklärung und Quantifizierung genutzt. Eine Arbeitsgruppe an der Berliner Bundesanstalt für Materialforschung und -prüfung (BAM) und am Karlsruher Institut für Technologie (KIT) hat die Möglichkeiten untersucht, die NMR-Spektroskopie auch als Online-Methode für das Monitoring chemischer Reaktionen in der Prozesskontrolle einsetzbar zu machen.
Die Entwicklung innovativer Medium-Resolution-NMR-Spektrometer eröffnet eine Reihe bemerkenswerter Applikationen für die Qualitätskontrolle, die akademische Ausbildung und die Prozessanalytik. Die Verwendung von Permanentmagneten erlaubt den Einsatz der NMR-Spektroskopie in industriellen Prozessumgebungen.
Derzeit finden gravierende Veränderungen im Umfeld der Informations- und Kommunikationstechnik statt, die eine große Chance für die optimierte Prozessführung und Wertschöpfung mit darauf abgestimmten vernetzt kommunizierenden Sensoren bieten. Diese Art „smarte“ Sensoren stellen Dienste innerhalb eines Netzwerks bereit und nutzen Informationen daraus. Dieses ist die Voraussetzung für die Realisierung von Cyber Physical Systems (CPS) innerhalb zukünftiger Automatisierungskonzepte für die Prozessindustrie, wie sie auch durch das Zukunftsprojekt „Industrie 4.0“ adressiert werden.
Initiiert von NAMUR und VDI/GMA und unter Mitwirkung der Unternehmen ABB, BASF, BTS, Bilfinger Maintenance, Endress+Hauser, Evonik, Festo, Krohne, Lanxess, Siemens, des Fraunhofer ICT, der HS Reutlingen und der BAM (Projektleitung) entstand jetzt die grundlegend aktualisierte und überarbeitete Technologie-Roadmap „Prozess-Sensoren 4.0“, die am 06. November 2015 auf der NAMUR-Hauptsitzung in Bad Neuenahr wurde.
Online NMR spectroscopy as an essential tool in a multi-spectral reaction understanding approach
(2015)
Medium-resolution nuclear magnetic resonance spectroscopy (MR-NMR) currently develops to an important analytical tool for both quality control and processmonitoring. In contrast to high-resolution onlineNMR (HR-NMR),MR-NMRcan be operated under rough environmental conditions. A continuous re-circulating stream of reaction mixture fromthe reaction vessel to the NMR spectrometer enables a non-invasive, volume integrating online analysis of reactants and products. Here, we investigate the esterification of 2,2,2-trifluoroethanol with acetic acid to 2,2,2-trifluoroethyl acetate both by 1H HR-NMR (500MHz) and 1H and 19F MRNMR (43MHz) as amodel system. The parallel online measurement is realised by splitting the flow,which allows the adjustment of quantitative and independent flow rates, both in the HR-NMR probe as well as in the MR-NMR probe, in addition to a fast bypass line back to the reactor. One of the fundamental acceptance criteria for online MR-MNR spectroscopy is a robust data treatment and evaluation strategy with the potential for automation. The MR-NMR spectra are treated by an automated baseline and phase correction using the minimum entropy method. The evaluation strategies comprise (i) direct integration, (ii) automated line fitting, (iii) indirect hard modelling (IHM) and (iv) partial least squares regression (PLS-R). To assess the potential of these evaluation strategies for MR-NMR, prediction results are compared with the line fitting data derived from the quantitative HR-NMR spectroscopy. Although, superior results are obtained from both IHM and PLS-R for 1H MR-NMR, especially the latter demands for elaborate data pretreatment, whereas IHM models needed no previous alignment.
Die gravierenden Veränderungen im Umfeld der Informations- und Kommunikationstechnik beeinflussen auch die Prozessautomation und sind zugleich eine Chance. Denn die Automatisierungskonzepte gemäß Industrie 4.0 sichern den Wettbewerbsvorteil einer Volkswirtschaft. Ein zentrales Element bilden dabei smarte Sensoren, die Dienste innerhalb eines Netzwerks bereitstellen und Information daraus nutzen. Die im November 2015 vorgestellte Technologieroadmap Prozess-Sensoren 4.0 [1] zeigt Anforderungen an smarte Prozess-Sensoren auf. Der Beitrag befasst sich mit den Fragen „Was kann der Prozess-Sensor zu Industrie 4.0 beitragen?“ und „Welchen Nutzen bringt Industrie 4.0 für den Prozess-Sensor?“
Resolving overlapping peaks of multiple components. Relative primary analytical method - Fundamental relationship of qNMR.
Heute wie morgen müssen Prozess-Sensoren zuerst die Aufgabe des Messens und der Generierung von Prozessinformationen erfüllen. Die Mess-Signale gehen in der Regel auf physikalische oder chemische Größen zurück, werden durch eine Kennlinie repräsentiert und lassen sich kalibrieren. Heute muss man dazu einen großen Aufwand betreiben, denn die physikalischen oder chemischen Informationen werden in vielen Fällen nicht direkt gemessen, sondern verbergen sich in Rohdaten, z. B. in einem optischen Spektrum. Diese Kalibrierungen können für komplexe Sensoren teilweise mehr Kostenaufwand bedeuten, als das Messgerät selbst.
Resource Analytics with the help of process analytical technology and the use of online methods is becoming increasingly important for mining and processing technologies and for the recovery of raw materials from secondary raw materials. Current online analytical methods like laser-induced breakdown spectroscopy (LIBS), X-ray fluorescence analysis (RFA), or Raman spectroscopy for the characterization of primary and secondary raw materials are increasingly being used in close association with the technologies for exploration and extraction, mechanical and metallurgical processing, as well as for recycling. Because of the complex matrices such methods are a considerable challenge at the same time. The use of reference materials, which are derived from appropriate matrices, can considerably shorten calibration and method development times. As an example, the development of an online process control method for recovery of phosphorus from sewage sludge ashes is discussed. A combination of LIBS and RFA was developed for the determination of element contents in sewage sludge ashes and their products coming from a thermo-chemical reprocessing step, which removes pollutants.
Troubleshooting Samples Analytics:
Impurities in products: unexpected & unwanted occurrence, unknown identity, analytical method unclear, often various analytical methods, necessary, short response time important (< 1 d), benefits: allocation of its source within hours safes cost
• Investigations planned, coordinated and documented by TSA team
• Variety of analytical methods available
Online NMR spectroscopy is an excellent tool to study complex reacting multicomponent mixtures and gain process insight and understanding. For online studies under process conditions, flow NMR probes can be used in a wide range of temperature and pressure. This paper compiles the most important aspects towards quantitative process NMR spectroscopy in complex multicomponent mixtures and provides examples. After NMR spectroscopy is introduced as an online method and for technical samples without sample preparation in deuterated solvents, influences of the residence time distribution, pre-magnetization, and cell design are discussed. NMR acquisition and processing parameters as well as data preparation methods are presented and the most practical data analysis strategies are introduced.
Supernatants from a fermentation process of Pichia pastoris were investigated by Raman spectroscopy. Using partial least squares regression, the principal substrates glycerol and methanol could be predicted, however not the expressed protein. To gain further insight, a priori prepared calibration samples were studied by vibrational-, UV/Vis-, and fluorescence spectroscopy. For the quantification of glycerol and methanol, Raman spectroscopy was identified as the most sensitive technique, and superior to near-infrared spectroscopy, but not for protein contents below 1 g L–1. Both UV/Vis absorption and fluorescence spectroscopy are well suited for the quantification of protein, however, best results were obtained with UV/Vis absorption.
Die Bundesanstalt für Materialforschung und -prüfung (BAM) ist eine wissenschaftlich technische Bundesoberbehörde im Geschäftsbereich des Bundesministeriums für Wirtschaft und Energie (BMWi), die über einen gesetzlichen Auftrag für die Sicherheit in Technik und Chemie verfügt und auf nahezu 150 Jahre zurückblicken kann. Vor diesem Hintergrund forscht, entwickelt, und prüft die BAM in den fünf Themenfeldern Energie, Infrastruktur, Umwelt, Material und Analytical Sciences mit einer unikalen Vielfalt an analytischen Methoden.
Ugly Spectra and Lousy interfaces – Challenges for Compact NMR Spectroscopy in Process Control
(2016)
With the introduction of advanced process analytical technology, the closeness of key process variables to their limits can be directly controlled and the product can be classified or even released in real time.
Compact NMR instruments can make NMR spectroscopy accessible in industrial and harsh environments for process control.
qNMR provides the most universally applicable form of direct purity determination without need for reference materials of impurities or the calculation of response factors but only exhibiting suitable NMR properties. The development of CRMs addressing qNMR specific measurement issues will give analysts compounds ideally suited for the analytical method and also provide full characterisation of qNMR related parameters to enable more realistic uncertainty budgets. These materials will give users the tools to exploit qNMR more easily and enable them to speed up analytical method development and reduce the time and financial burden of multiple analytical testing.
Homogen katalysierte Reaktionen sind wichtige Werkzeuge der chemischen Industrie. Milde Reaktionsbedingungen und hohe Selektivitäten führen zu einer energie- und ressourcenschonenden Produktion. Ein bedeutender Prozessschritt ist die Hydroformylierung. Hier kommen Kobalt- und Rhodiumkomplexe mit mehrzähnigen Liganden zum Einsatz, die zumeist in wässriger Lösung vorliegen. Die Anwendbarkeit beschränkt sich demnach auf kurzkettige Edukte mit hinreichender Wasserlöslichkeit.
The CLEAN ENERGY Flagship is an initiative designed to utilize recent game changing developments in digital, materials and manufacturing technologies to catalyze a radical paradigm shift towards clean, reliable, efficient and cost-optimal energy.
Unifying and drastically accelerating radically new energy material design, processing and integration across the entire value chain addressing energy production, conversion, storage and systems.
CLEAN ENERGY participants are all distinguished research organisations that each benefit from their own industry networks and contacts with regions and state-level activities and have a long history of collaborating with each other (for 10 years now under the umbrella of EERA) within a European collaborative framework.
Through EERA, CLEAN ENERGY aims to become a crucial partner in the SET-Plan, supporting long-lasting approaches through its established networks and internal collaborations.
Die Nutzung von Sensortechnologien, insbesondere im Bereich der Gasdetektion mit einem Schwerpunkt auf Wasserstoff, spielt eine entscheidende Rolle in verschiedenen Anwendungsbereichen der Wasserstofftechnologie. Sicherheitsüberwachung, Leckdetektion und Prozesskontrolle gehören zu den prominenten Anwendungsgebieten dieser Sensortechnologien. Ein zentrales Ziel ist die Erkennung von freigesetztem Wasserstoff sowie die genaue Bestimmung des Wasserstoff-Luftverhältnisses mithilfe von Gassensoren. Dies ist von entscheidender Bedeutung, um potenzielle Gefahren frühzeitig zu erkennen und angemessene Maßnahmen zu ergreifen.
Ein weiterer Schwerpunkt dieses Beitrags liegt auf der Analytik und der Verwendung zertifizierter Referenzmaterialien in Verbindung mit Metrologie für die Wasserstoffspeicherung. Dies gewährleistet eine präzise und zuverlässige Charakterisierung von Wasserstoff und unterstützt die Entwicklung sicherer Speichertechnologien. Im Rahmen des Euramet-Vorhabens Metrology for Advanced Hydrogen Storage Solutions (MefHySto) wird eine Kurzvorstellung präsentiert.
Der Vortrag stellt zwei zerstörungsfreie Prüfverfahren zum strukturellen Zustandsüberwachung (Structural Health Monitoring, SHM) für Wasserstofftechnologien vor. Insbesondere die Fehlstellenerkennung mittels geführter Ultraschallwellen spielt eine bedeutende Rolle bei der Lebensdauerüberwachung von Wasserstoffspeichern. Ein weiterer Aspekt ist die Anwendung faseroptischer Sensorik zur Schadensfrüherkennung von Wasserstoffspeichern. Diese zerstörungsfreien Prüfverfahren ermöglichen eine präzise und frühzeitige Identifizierung von Schäden, was die Sicherheit und Effizienz von Wasserstoffspeichersystemen entscheidend verbessert.
This key comparison aims to assess the capabilities of the participants to determine the amount-of-substance fraction oxygen in nitrogen. The GAWG has classified this as a track B comparison, due to the unexpected 50 μmol/mol argon mole fraction content of the transfer standards, which effects the achievable performance of some measurement techniques such a GC-TCD. The separation of oxygen and argon is challenging, and not all systems in use are equally well designed for it. As this analytical challenge due to a substantial fraction of argon in the transfer standards became a reality, the Gas Analysis Working Group (GAWG) decided to qualify this key comparison as a regular key comparison and not as a core comparison, which may be used to support calibration and measurement capabilities (CMCs) for oxygen in nitrogen, or for oxygen in nitrogen mixtures containing argon only (see also the section on support to CMCs).
Currently research in chemical manufacturing moves towards flexible plug-and-play approaches focusing on modular plants, capable of producing small scales on-demand with short down-times between individual cam-paigns. This approach allows for efficient use of hardware, a faster optimization of the process conditions, and thus, an accelerated introduction of new products to the market. Driven mostly by the search for chemical syntheses under biocompatible conditions, so-called “click” chemistry rapidly became a growing field of research. The re-sulting simple one-pot reactions are so far only scarcely accompanied by an adequate optimization via compara-bly straightforward and robust analysis techniques. Here we report on a fast and reliable calibration-free online high field NMR monitoring approach for technical mixtures. It combines a versatile fluidic system, continuous-flow measurement with a time interval of 20 s per spectrum, and a robust, automated algo-rithm to interpret the ob-tained data. All spectra were acquired using a 500 MHz NMR spectrometer (Varian) with a dual band flow probe having a 1/16 inch polymer tubing working as a flow cell. Single scan 1H spectra were recorded with an acquisition time of 5 s, relaxation delay of 15 s.
Currently, research in chemical manufacturing moves towards flexible plug-and-play approaches focusing on modular plants, capable of producing small scales on-demand with short down-times between individual campaigns. This approach allows for efficient use of hardware, a faster optimization of the process conditions, and thus, an accelerated introduction of new products to the market. Driven mostly by the search for chemical syntheses under biocompatible conditions, so-called “click” chemistry rapidly became a growing field of research. The resulting simple one-pot reactions are so far only scarcely accompanied by an adequate optimization via comparably straightforward and robust analysis techniques.
Here we report on a fast and reliable calibration-free online high field NMR monitoring approach for technical mixtures. It combines a versatile fluidic system, continuous-flow measurement with a time interval of 20 s per spectrum, and a robust, automated algorithm to interpret the obtained data. All spectra were acquired using a 500 MHz NMR spectrometer (Varian) with a dual band flow probe having a 1/16-inch polymer tubing working as a flow cell. Single scan 1H NMR spectra were recorded with an acquisition time of 5 s, relaxation delay of 15 s. As a proof-of-concept, the thiol-ene coupling between N-boc cysteine methyl ester and allyl alcohol was conducted in non-deuterated solvents while its time-resolved behaviour was characterised with step tracer experiments.
Through the application of spectral modeling the signal area for each reactant can be deconvoluted in the online spectra and thus converted to the respective concentrations or molar ratios. The signals which were suitable for direct integration were used herein for comparison purposes of both methods.
This key comparison aims to assess the core capabilities of the participants in gas analysis. Such competences include, among others, the capabilities to prepare Primary Standard gas Mixtures (PSMs), perform the necessary purity analysis on the materials used in the gas mixture preparation, the verification of the composition of newly prepared PSMs against existing ones, and the capability of calibrating the composition of a gas mixture. According to the Strategy for Key Comparisons of the Gas Analysis Working Group, this key comparison is classified as an RMO track A key comparison.
The artefacts were binary mixtures of propane in nitrogen at a nominal amount-of-substance fraction level of 1000 μmol/mol. The values and uncertainties from the gravimetric gas mixture preparation were used as key comparison reference values (KCRVs). Each transfer standard had its own KCRV. The results are generally good. All results are within ± 1 % of the KCRV.
Driven mostly by the search for chemical syntheses under biocompatible conditions, so called "click" chemistry rapidly became a growing field of research. The resulting simple one-pot reactions are so far only scarcely accompanied by an adequate optimization via comparably straightforward and robust analysis techniques possessing short set-up times. Here, we report on a fast and reliable calibration-free online NMR monitoring approach for technical mixtures. It combines a versatile fluidic system, continuous-flow measurement of 1H spectra with a time interval of 20 s per spectrum, and a robust, fully automated algorithm to interpret the obtained data. As a proof-of-concept, the thiol-ene coupling between N-boc cysteine methyl ester and allyl alcohol was conducted in a variety of non-deuterated solvents while its time-resolved behaviour was characterized with step tracer experiments. Overlapping signals in online spectra during thiol-ene coupling could be deconvoluted with a spectral model using indirect hard modeling and were subsequently converted to either molar ratios (using a calibrationfree approach) or absolute concentrations (using 1-point calibration). For various solvents the kinetic constant k for pseudo-first order reaction was estimated to be 3.9 h-1 at 25 °C. The obtained results were compared with direct integration of non-overlapping signals and showed good agreement with the implemented mass balance.
Quantitative NMR spectroscopy for gas analysis for production of primary reference gas mixtures
(2017)
Due to its direct correlation to the number of spins within a sample quantitative NMR spectroscopy (qNMR) is a promising method with absolute comparison abilities in complex systems in technical, as well as metrological applications. Most of the samples studied with qNMR are in liquid state in diluted solutions, while gas-phase applications represent a rarely applied case. Commercially available NMR equipment was used for purity assessment of liquid and liquefied hydrocarbons serving as raw materials for production of primary reference gas standards. Additionally, gas-phase studies were performed within an online NMR flow probe, as well as in a high-pressure NMR setup to check feasibility as verification method for the composition of gas mixtures.
Bei der Entwicklung pharmazeutischer Wirkstoffe werfen Substanzen mit einer geringen Löslichkeit, Auflösungsrate und damit einhergehend schlechten Bioverfügbarkeit immer größere Probleme auf. Diese Eigenschaften und nicht etwa toxikologische Eigenschaften oder schlechte Wirksamkeit sorgen dafür, dass es weniger als 1 % aller Wirkstoffe bis in die Markteinführung schaffen. Eine Reihe von Ansätzen zur Verbesserung der schlechten Wasserlöslichkeit konnten bereits etabliert werden. Hierunter zählen die gezielte Salzbildung bzw. Salzscreening, Solubilisierung mit Cosolventien oder die Nutzung von Polymeren als mögliche Transportwege. Eine weitere Möglichkeit bietet die Bildung verschiedener polymorpher Formen, sowohl der Einzelkomponente als auch von den verschiedenen Mehrkomponentenverbindungen.
This project concerns the purity analysis of nitrogen as used in reference gas mixture preparation. This project was carried out without adding impurities to the gas used for this comparison, and is therefore more representative to evaluate the analysis of CO, CO2, CH4, O2, Ar and H2O impurities in high purity nitrogen. The analysis of the amount–of–substance fraction water was optional.
Two 50 litre high purity nitrogen cylinders were purchased from a well-qualified supplier of specialty gases. The listed components were expected to be present in the pure nitrogen at the target levels as a result of the purification of the nitrogen. From the start of this comparison it was clear that the comparison may not lead to reference values for the constituents analysed.
The results indicate that analyses of high purity gases are often limited by the limits of detection of analytical equipment used. The reports of the participating laboratories also indicate that there is no agreed method of determination of the uncertainty on a detection Limit value. The results provide useful information on the Performance of participants. For all analysed components there is reasonable agreement in results for LNE, VSL, Metas and NPL.
For BAM only the Argon result is in agreement.
Currently research in chemical manufacturing moves towards flexible plug-and-play approaches focusing on modular plants, capable of producing small scales ondemand with short down-times between individual campaigns. This approach allows for efficient use of hardware, a faster optimization of the process conditions, and thus, an accelerated introduction of new products to the market. Driven mostly by the search for chemical syntheses under biocompatible conditions, so-called “click” chemistry rapidly became a growing field of research. The resulting simple one-pot reactions are so far only scarcely accompanied by an adequate optimization via comparably straightforward and robust analysis techniques. Here we report on a fast and reliable calibration-free online high field NMR monitoring approach for technical mixtures. It combines a versatile fluidic system, continuous-flow measurement with a time interval of 20 s per spectrum, and a robust, automated algorithm to interpret the obtained data. All spectra were acquired using a 500 MHz NMR spectrometer (Varian) with a dual band flow probe having a 1/16 inch polymer tubing working as a flow cell. Single scan 1H spectra were recorded with an acquisition time of 5 s, relaxation delay of 15 s. As a proof-of-concept, the thiol-ene coupling between N-boc cysteine methyl ester and allyl alcohol was conducted in non-deuterated solvents while its time-resolved behaviour was characterised with step tracer experiments Through the application of spectral modeling the signal area for each reactant can be deconvoluted in the online spectra and thus converted to the respective concentrations or molar ratios. The signals which were suitable for direct integration were used herein for comparison purposes of both methods.
Chemical and pharmaceutical companies have to find new paths to survive successfully in a changing environment, while also finding more flexible ways of product and process development to bring their products to market more quickly – especially high-quality high-end products like fine chemicals or pharmaceuticals. The potential of digital technologies belongs to these.
A current approach uses flexible and modular chemical production units, which can produce different high-quality products using multi-purpose equipment with short downtimes between campaigns and reduce the time to market of new products. At the same time, we need to move towards knowledge-based production that takes into account all essential equipment, process and control data from plants and laboratories and makes valuable expertise available and transferable. The potential of data from production together with its contextual information is often not yet consistently used today for a comprehensive understanding of production.
By giving examples this paper outlines a possible more holistic approach to digitalisation and the use of machine-based methods in the production of specialty chemicals and pharmaceuticals through the introduction of integrated and networked systems and processes.
Die quantitative NMR-Spektroskopie (qNMR) gewinnt in den letzten Jahren immer mehr an Bedeutung, speziell hinsichtlich der Anwendung auf komplexe Fragestellungen der analytischen Chemie. Ein großer Vorteil dieser Methode ist die Möglichkeit der Relativquantifizierung durch das „Zählen von Kernspins" in der Probe. Unter der Voraussetzung eines korrekt ausgeführten NMR-Experiments ist so der direkte Vergleich von Signalflächen im Spektrum möglich, ohne dass zuvor zwingend eine Kalibrierung notwendig ist.
Optimizing the Green Synthesis of ZIF-8 by Reactive Extrusion Using In Situ Raman Spectroscopy
(2023)
We report the scale-up of a batch solid synthesis of zeolitic imidazolate framework-8 (ZIF-8) for reactive extrusion. The crystalline product forms in the extruder directly under the mixture of solid 2-methylimidazole and basic zinc carbonate in the presence of a catalytic amount of liquid. The process parameters such as temperature, liquid type, feeding rate, and linker excess were optimized using the setup specifically designed for in situ Raman spectroscopy. Highly crystalline ZIF-8 with a Brunauer–Emmett–Teller (BET) surface area of 1816 m2 g–1 was quantitatively prepared at mild temperature using a catalytic amount of ethanol and a small excess of the linker. Finally, we developed a simple and comprehensive approach to evaluating the environmental friendliness and scalability of metal–organic framework (MOF) syntheses in view of their large-scale production.
Anhand von Beispielen wird in diesem Vortrag ein möglicher ganzheitlicherer Ansatz für die Digitalisierung und den Einsatz maschinengestützter Prozesse bei der Herstellung von Spezialchemikalien und Arzneimitteln durch die Einführung integrierter und vernetzter Systeme und Prozesse skizziert. Ein aktueller Ansatz und ein Beispiel in diesem Vortrag sind flexible und modulare chemische Produktionseinheiten, die Mehrzweckanlagen nutzen, um verschiedene hochwertige Produkte mit kurzen Stillstandszeiten zwischen den Kampagnen herzustellen und die Markteinführungszeit für neue Produkte zu verkürzen.
Als zweites Beispiel wird kurz die Testplattform Wasserstofftankstelle vorgestellt, die als moderne Anlage der Prozessindustrie betrachtet werden kann, vergleichbar mit einer Anlage aus der chemischen oder pharmazeutischen Industrie. An ihr lassen sich alle derzeit entlang der Digitalen Transformation diskutierten Konzepte implementieren, um sie zu standardisieren und zu validieren. Dazu gehören Konzepte zur Konnektivität von Sensoren und Aktoren aus der Feldebene in höhere Ebenen der Automatisierung oder zur Einbringung zusätzlicher Sensoren oder Sensornetzwerke, die zunehmend flexibler gestaltet werden soll, die sichere und nachvollziehbare Parametrierung von Automatisierungskomponenten – vielleicht aus einem digitalen Abbild (Verwaltungsschale bzw. „Digitaler Zwilling“) heraus, Konzepte zur vorausschauenden Wartung („Predictive Maintenance“), Konzepte zu digitalen Entscheidungsprozessen, Zertifikaten und Signaturen oder der zunehmende Einsatz von komplexen Auswertungsalgorithmen und Applikationen in der Feldebene („Embedded Computing“) oder der „Kante“ zu Cloudbasierten Systemen der Informationstechnik („Edge-Computing“).
Die beiden Beispiele sollen aktuelle Entwicklungsachsen des industriellen Messwesens im Rahmen der industriellen Automation aufzeigen, in denen Messwerte, deren Messunsicherheiten und Kontextinformationen eine wichtige Rolle einnehmen.
Introduction
NMR spectroscopy is one of the most important analytical methods in organic chemistry. While most analyses are carried out qualitatively with the aim of substance identification and structure elucidation, quantitative NMR spectroscopy (qNMR) is increasingly gaining importance in research and industry. qNMR provides the most universally applicable form of direct purity determination without need for reference materials of impurities or the calculation of response factors but only exhibiting suitable NMR properties.
Methods
One of the most attractive features of quantitative NMR spectroscopy is that the NMR peak areas can be used directly for concentration quantification without further calibration. Another advantage of NMR spectroscopy is that the method has a high linearity between absolute signal area and sample concentration, which makes it an absolute analytical comparison method that is independent of the matrix. This enables automated robust data evaluation strategies that can be used for online applications of qNMR spectroscopy.
Jancke et al. proposed NMR spectroscopy as a relative primary analytical method because it can be fully described by mathematical equations from which a complete uncertainty budget can be derived, allowing it to be used at the highest metrological level. Weber et al. discussed in detail important aspects of the procedure that enable the realisation of low measurement uncertainties in qNMR measurements. Since certification of CRM requires expanded mea¬sure¬ment uncertainties of less than 0.5 % (relative), the work of Weber et al. demonstrated for the first time that qNMR can fulfil this criterion.
Results
To date, further comparative studies have been carried out in metrology and industry, demonstrating the performance of quantitative NMR spectroscopy and further reducing measurement uncertainties. The development of validation concepts and the commercial availability of suitable certified reference materials facilitate the application, especially in the usually highly regulated industrial environment. Users can thus accelerate the development of analytical methods. The talk will cover a wide range of topics from current metrological activities to new challenges for qNMR spectroscopy and also deals with aspects such as validation and accreditation.
Innovative aspects
• qNMR provides the most universally applicable form of direct purity determination
• Expanded measurement uncertainties lower than 0.15 % (relative) possible
• Benchtop NMR instruments increasingly used for qNMR spectroscopy
The course of the changeover of UGS from natural gas to hydrogen varies depending on the type of the underground gas storage (UGS). In caverns a changeover to high H2-contents can be achieved quickly, while pore storage tanks must be converted over long periods of time. The analytical requirements are correspondingly different. This information has been compiled through expert statement by underground storage operators.
A significant number of new UGS is currently not expected. Public funds (project funding) are currently being raised for the conversion of caverns to hydrogen. In addition, investigations and evaluations of the material are currently being carried out at various storage facilities in order to determine the possibilities and costs of a conversion. H2 admixtures to natural gas, but also pure H2 caverns are considered. The bottleneck seems to be the availability of large volumes of hydrogen. The analytical requirements along with the different hydrogen qualities, which are currently discussed were compiled through expert discussions with underground storage operators and are at hand as early impact results.
Der Vortrag ist ein Impulsvortrag, der kurz in die Prozessketten der potentiellen Wasserstoffwirtschaft einführt. An vielen Stellen werden spezifische Sensoren benötigt, die die Prozess-Sicherheit und die Zuverlässigkeit von Qualitätsparametern gewährleisten. Es wird auch kurz auf die Forschungsföerderungslandschaft zu diesem Thema eingegangen.
The application of compact NMR instruments to hot flowing samples or exothermically reacting mixtures is limited by the temperature sensitivity of permanent magnets. Typically, such temperature effects directly influence the achievable magnetic field homogeneity and hence measurement quality. The internal-temperature control loop of the magnet and instruments is not designed for such temperature compensation. Passive insulation is restricted by the small dimensions within the magnet borehole. Here, we present a design approach for active heat shielding with the aim of variable temperature control of NMR samples for benchtop NMR instruments using a compressed airstream which is variable in flow and temperature. Based on the system identification and surface temperature measurements through thermography, a model predictive control was set up to minimise any disturbance effect on the permanent magnet from the probe or sample temperature. This methodology will facilitate the application of variable-temperature shielding and, therefore, extend the application of compact NMR instruments to flowing sample temperatures that differ from the magnet temperature.
Modular chemical production is a tangible implementation of the digital transformation of the specialty chemicals process industry. In particular, it enables acceleration of process development and thus faster time to market by flexibly interconnecting and orchestrating standardized physical modules and bringing them to life. For this purpose, specific (chemical) sensors of process analytics are needed, preferably without lengthy calibration or spectroscopic model development.
An excellent example of a "direct" analytical method is online nuclear magnetic resonance (NMR) spectroscopy. NMR spectroscopy meets the requirements of a direct analytical method because of the direct correlation between the signal area in the spectrum ("counting" the nuclear spins) and the analyte amount of substance concentrations. It is also extremely linear over the concentration range.
With the availability of compact benchtop NMR instruments, it is now possible to bring NMR spectroscopy directly into the field, in close proximity to specialized laboratory facilities, pilot plants, and even industrial-scale production facilities. The first systems are in TRL 8 (Qualified System with Proof of Functionality in the Field).
The presentation will discuss the many building blocks of online nuclear magnetic resonance spectroscopy, from flow cells to automated data analysis.
The European project MefHySto addresses the need of large-scale energy storage, which is required for a shift to renewable energy supply. The project is funded by the European Metrology Programme on Innovation and Research (EMPIR) and consists of 14 consortium partners from all over Europe (www.mefhysto.eu). It is demonstrated, how MefHySto is contributing to the EMN for Energy Gases aiming at prioritisation of the measurement gaps and challenges interacting with the EMN stakeholders.
In dieser Arbeit werden die Grundlagen der Normung, die Entstehung einer Norm und die für die Gasanalytik relevanten Normungsgremien kurz dargestellt. Dazu werden die wichtigsten Normen zur Gasanalytik entlang des analytischen Prozesses gruppiert und aufgeführt. Schließlich wird als Anwendungsbeispiel aus der eigenen Praxis der Prozess von der Herstellung bis zur Zertifizierung eines Kalibriergases beschrieben.
Chemical and pharmaceutical companies have to find new paths to survive successfully in a changing environment, while also finding more flexible ways of product and process development to bring their products to market more quickly – especially high-quality high-end products like fine chemicals or pharmaceuticals. A current approach uses flexible and modular chemical production units, which can produce different high-quality products using multi-purpose equipment with short downtimes between campaigns and reduce the time to market of new products.
NMR spectroscopy appeared as excellent online analytical tool and allowed a modular data analysis approach, which even served as reliable reference method for further Process Analytical Technology (PAT) applications. Using the available datasets, a second data analysis approach based on artificial neural networks (ANN) was evaluated. Therefore, amount of data was augmented to be sufficient for training. The results show comparable performance, while improving the calculation time tremendously. In future, such fully integrated and interconnecting “smart” systems and processes can increase the efficiency of the production of specialty chemicals and pharmaceuticals.
At the end of the article, ideas for solutions are discussed in order to speed up the implementation of new special products from the point of view of process analytics and to network the existing process chains more closely.
Um die internationale Spitzenposition deutscher Unternehmen der Prozessindustrie auch in Zukunft sicher zu stellen, müssen die Unternehmen ihre Prozesse und Geschäftsabläufe digitalisieren und gemeinsam mit der Forschung innovative neue Methoden, Apparate, Anlagen, Sensoren und Automatisierungstechnik sowie Datenkonzepte entwickeln. All dies erfordert den Aufbau neuer Fähigkeiten, Investition in Talente, interdisziplinäre Kommunikation zwischen verschiedenen Personen und Abteilungen und eine Bereitschaft zur Veränderung.
Chemical and pharmaceutical companies need to find new ways to survive successfully in a changing environment, while finding more flexible ways of product and process development to bring their products to market faster - especially high-value, high-end products such as fine chemicals or pharmaceuticals. This is complicated by changes in value chains along a potential circular economy.
One current approach is flexible and modular chemical production units that use multi-purpose equipment to produce various high-value products with short downtimes between campaigns and can shorten time-to-market for new products. Online NMR spectroscopy will play an important role for plant automation and quality control, as the method brings very high linearity, matrix independence and thus works almost calibration-free. Moreover, these properties ideally enable automated and machine-aided data analysis for the above-mentioned applications.
Using examples, this presentation will outline a possible more holistic approach to digitalization and the use of machine-based processes in the production of specialty chemicals and pharmaceuticals through the introduction of integrated and networked systems and processes.
Integrierte und vernetzte Systeme und Prozesse – Eine Perspektive für die smarte Laborinfrastruktur
(2022)
Chemie- und Pharmaunternehmen müssen neue Wege gehen, um in einem sich wandelnden Umfeld erfolgreich zu überleben, und gleichzeitig flexiblere Wege der Produkt- und Prozessentwicklung finden, um ihre Produkte schneller auf den Markt zu bringen - vor allem hochwertige High-End-Produkte wie Feinchemikalien oder Arzneimittel. Dazu gehört auch das Potenzial der digitalen Technologien, um ein umfassenderes Wissensmanagement zu ermöglichen.
Eine wichtige Wissensquelle sind analytische Labors, die Unternehmensweit aktiv sind – von F&E bis zur Produktion. Die ganzheitliche Einbindung von analytischen Labors und ein unternehmensweites Daten- und Wissensmanagement sind wichtige Bausteine zur Integration und Vernetzung aller Systeme und Prozesse. Das Potenzial von Daten aus der Produktion mit ihren Kontextinformationen wird heute oft noch nicht konsequent für ein umfassendes Verständnis der Produktion genutzt.
Dieser Beitrag skizziert anhand von Beispielen einen möglichen ganzheitlicheren Ansatz zur Digitalisierung und zum Einsatz maschineller Verfahren in der Produktion von Spezialchemikalien und Pharmazeutika durch die Einführung integrierter und vernetzter Systeme und Prozesse.
Die BAM setzt in ihren analytischen Labors zunehmend Labor-Robotik ein, um gefähliche oder zeitraubende Routineaufgaben zu automatisieren. Durch Automation kann auch die Reproduzierbarkeit solcher Anwendungen erhöht werden.
Im Beitrag werden einige aktuelle Beispiele aus den Analytiklabors diskutiert, wie z. B. die Anwendung für die Herstellung und RFA-Analytik von Gläsern, eine Feinwäge-Robotik für 10-L-Gaszylinder im Rahmen der Herstellung von Primärnormalen oder die Automatisierung von Probenpräsentationen für optische Spektroskopie und chemical Imaging. Auch wird kurz auf den Einsatz von Speicherprogrammierbaren Steuerungen in der modularen Laborautomation und die Virtualisierung von analytischen Laborrechnern eingengangen.
Competence Centre H2Safety@BAM – Safeguarding the Quality Infrastructure in the Hydrogen Economy
(2022)
Hydrogen is a central component of the energy transition and the European Green Deal for a climate-neutral Europe. To achieve the goals defined for 2050, the EU and the German government have developed a framework for action and are making long-term investments in research, development, and the rapid implementation of innovative hydrogen technologies.
With the Competence Centre "H2Safety@BAM", BAM is creating the safety-related prerequisites for the successful implementation of hydrogen technologies at national as well as European level.
To this end, BAM conducts research, testing and consulting in a holistic and inter-disciplinary manner under one roof – in the Competence Centre H2Safety@BAM. The activities of the competence centre focus on ensuring the safety of infra-structures, plants, and processes as well as innovative hydrogen transport and storage systems based on digital quality testing and the experimental testing of components and systems. It thus creates the prerequisites for the implementation and adaptation of legal framework conditions as well as for standardization. Closely related to this are investigations into the properties and compatibility of metallic materials and polymers as well as friction systems for the safe operation of components, plants, processes, and systems. This interdisciplinary and holistic approach is complemented by the development of gas analytics and suitable sensors, online measurements of gas properties in process control, test scenarios under real conditions as well as impact assessments of accidents and risk assessments and risk management systems derived from them. With its portfolio of tasks and competences, BAM builds trust in the safety and reliability of technical system solutions for hydrogen.
Chemical and pharmaceutical companies have to find new paths to survive successfully in a changing environment, while also finding more flexible ways of product and process development to bring their products to market more quickly – especially high-quality high-end products like fine chemicals or pharmaceuticals. A current approach uses flexible and modular chemical production units, which can produce different high-quality products using multi-purpose equipment with short downtimes between campaigns and reduce the time to market of new products.
NMR spectroscopy appeared as excellent online analytical tool and allowed a modular data analysis approach, which even served as reliable reference method for further Process Analytical Technology (PAT) applications. Using the available datasets, a second data analysis approach based on artificial neural networks (ANN) was evaluated. Therefore, amount of data was augmented to be sufficient for training. The results show comparable performance, while improving the calculation time tremendously. In future, such fully integrated and interconnecting “smart” systems and processes can increase the efficiency of the production of specialty chemicals and pharmaceuticals.
Chemical and pharmaceutical companies need to find new ways to survive successfully in a changing environment, while finding more flexible ways of product and process development to bring their products to market faster - especially high-value, high-end products such as fine chemicals or pharmaceuticals. This is complicated by changes in value chains along a potential circular economy.
One current approach is flexible and modular chemical production units that use multi-purpose equipment to produce various high-value products with short downtimes between campaigns and can shorten time-to-market for new products. Online NMR spectroscopy will play an important role for plant automation and quality control, as the method brings very high linearity, matrix independence and thus works almost calibration-free. Moreover, these properties ideally enable automated and machine-aided data analysis for the above-mentioned applications.
Using examples, this presentation will outline a possible more holistic approach to digitalization and the use of machine-based processes in the production of specialty chemicals and pharmaceuticals through the introduction of integrated and networked systems and processes.
CCQM-K118 was an international key comparison on natural gas composition with two types of gases, i.e., a low calorific hydrogen-enriched natural gas and a high calorific LNG type of gas. There were 14 participating laboratories. The traveling standards (i.e., 14 mixtures each) were obtained from an external source and checked for homogeneity and stability before and after the participants' measurements at the two coordinating laboratories. The data evaluation was performed using a consensus value and a laboratory effect model. The results of the participants were benchmarked against a key comparison reference value computed from the largest consistent subset (LCS) of the submitted results, adjusted for the differences between the travelling standards. For the first time in a key comparison in gas analysis, the model included a term to account for excess variability in the LCS. Most of the participants reported one or a few (slightly) discrepant results. Partly this is due to the heterogeneity and heteroscedasticity of the datasets. In all, the results in this key comparison demonstrate the good comparability of the national measurement standards for natural gas composition maintained by the participating NMIs.
Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/.
The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).
To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database https://www.bipm.org/kcdb/.
The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
Mass Spectrometry (MS) and Nuclear Magnetic Resonance Spectroscopy (NMR) are critical components of every industrial chemical process as they provide information on the concentrations of individual compounds and by-products. These processes are carried out manually and by a specialist, which takes a substantial amount of time and prevents their utilization for real-time closed-loop process control. This paper presents recent advances from two projects that use Artificial Neural Networks (ANNs) to address the challenges of automation and performance-efficient realizations of MS and NMR. In the first part, a complete toolchain has been developed to develop simulated spectra and train ANNs to identify compounds in MS. In the second part, a limited number of experimental NMR spectra have been augmented by simulated spectra to train an ANN with better prediction performance and speed than state-of-theart analysis. These results suggest that, in the context of the digital transformation of the process industry, we are now on the threshold of a possible strongly simplified use of MS and MRS and the accompanying data evaluation by machine-supported procedures, and can utilize both methods much wider for reaction and process monitoring or quality control.
Das europäische Projekt MefHySto befasst sich mit dem Bedarf an großmaßstäblichen Energiespeichern, die für eine Umstellung der Energieversorgung auf erneuerbare Energien erforderlich sind. Eine solche Speicherung ist entscheidend, um Energie zu Spitzenzeiten zu liefern, wenn die erneuerbaren Energiequellen schwanken. Eine mögliche Lösung für die Energiespeicherung ist der großtechnische Einsatz von Wasserstoff. Die messtechnische Rückführbarkeit in der Energieinfrastruktur für die Wasserstoffspeicherung ist dann von entscheidender Bedeutung und eine bessere Kenntnis der chemischen und physikalischen Eigenschaften von Wasserstoff sowie rückführbare Messungen und validierte Techniken unverzichtbar.
Companies in the chemical industry have to tread new paths in order to survive successfully in a changed environment. This includes, in particular, the potential of digital technologies. The full integration and intelligent networking of systems and processes is making slow progress.
This talk is a tribute to the field level. It wants to encourage a more holistic approach to the digitalisation of the process industry based on smart sensors, actuators and communication and provides information on current technical perspectives, such as the "one-network paradigm", ad-hoc networking, edge computing, FPGAs, virtual machines or blockchain. These give smart sensors, actuators and communication a completely new perspective.