Filtern
Erscheinungsjahr
Dokumenttyp
- Beitrag zu einem Tagungsband (78)
- Zeitschriftenartikel (49)
- Beitrag zu einem Sammelband (37)
- Vortrag (22)
- Buchkapitel (8)
- Posterpräsentation (5)
- Sonstiges (2)
- Forschungsbericht (1)
Sprache
- Englisch (104)
- Deutsch (97)
- Mehrsprachig (1)
Schlagworte
- Beton (20)
- UHPC (14)
- Rheology (13)
- Concrete (12)
- Baustoffe (11)
- Zement (10)
- AKR (9)
- Durability (8)
- Self-compacting concrete (7)
- Alkali-Kieselsäure-Reaktion (6)
- Microstructure (6)
- Repair mortar (6)
- Acoustic emission (5)
- Alkali-silica reaction (5)
- Betoninstandsetzung (5)
- Building Materials (5)
- Dauerhaftigkeit (5)
- Hochleistungsbeton (5)
- Instandsetzungsmörtel (5)
- Nachhaltigkeit (5)
- Nanotechnologie (5)
- Polycarboxylate ether (5)
- Polypropylene fibres (5)
- Repair systems (5)
- Rheologie (5)
- Schallemissionsanalyse (5)
- Thermal treatment (5)
- Autogenes Schwinden (4)
- Concrete rehabilitation (4)
- Degradation (4)
- Gefüge (4)
- High performance concrete (4)
- Hydrothermal treatment (4)
- Modulare Systeme (4)
- Polycarboxylate (4)
- Sekundäre Gesteinskörnung (4)
- Setting (4)
- Shrinkage (4)
- Versuche (4)
- Zonation (4)
- ASR (3)
- Analytik (3)
- Bindemittel (3)
- Cement paste (3)
- Fließmittel (3)
- Hydratation (3)
- PCC (3)
- Polycarboxylatether (3)
- Polymer cement concrete (PCC) (3)
- SPCC (3)
- Scanning electron microscopy (3)
- Secondary aggregates (3)
- Sekundärrohstoffe (3)
- Selbstverdichtender Beton (3)
- Sprayed polymer cement concrete (SPCC) (3)
- Stabilising agent (3)
- Starch ether (3)
- Sustainability (3)
- Temperature (3)
- Tobermorite (3)
- Ultrasound (3)
- X-ray diffraction (XRD) (3)
- Accelerated concrete prism test (2)
- Admixtures (2)
- Adsorption (2)
- Alkali silica reaction (2)
- Architectural Concrete (2)
- Autoclaving (2)
- Autoklavierung (2)
- Automated expansion measurement (2)
- Betonangriff (2)
- Betonbrechsand (2)
- Betontechnologie (2)
- Bewertung (2)
- Biopolymers (2)
- C-S-H (2)
- C-S-H Phasen (2)
- Cement (2)
- Cementitious materials (2)
- Compressive strength (2)
- Computed tomography (2)
- Concrete analysis (2)
- Cyclic loading (2)
- Damage analysis (2)
- Desiccation (2)
- Digitalisierung (2)
- Einzelfaserdurchzugsversuch (2)
- Ermüdung (2)
- Ettringit (2)
- Facade Elements (2)
- Fasermodifikation (2)
- Fatigue (2)
- Festigkeit (2)
- Fibres (2)
- Forschung und Entwicklung (2)
- Grenzflächenaktive Verbindung (2)
- Heat evolution (2)
- Heat treatment (2)
- High temperatures (2)
- Hydraulic engineering structures (2)
- Hydroxylellestadite (2)
- Korrosion (2)
- Lichtmikroskopie (2)
- Mechanical strength (2)
- Mikrostruktur (2)
- Mineral additions (2)
- Mixture composition (2)
- Modellierung (2)
- Modified starch (2)
- Müllverbrennungsasche (2)
- Müllverbrennungsaschen (2)
- Natürliche puzzolanische Zusatzstoffe (2)
- Oberflächenfunktionalisierung (2)
- Phasenzusammensetzung (2)
- Polymer cement mortar (PCC) (2)
- Polypropylen-Fasern (2)
- Polysaccharides (2)
- Porenstruktur (2)
- Portland cement (2)
- Radar (2)
- Rasterelektronenmikroskopie (2)
- Recycling (2)
- Robustheit (2)
- Robustness (2)
- Röntgen-3D-Computertomographie (2)
- SCC (2)
- Schwinden (2)
- Secondary materials (2)
- Self-Cleaning Properties (2)
- Spalling (2)
- Sprayed polymer cement mortar (SPCC) (2)
- Stabilising agents (2)
- Sulfatangriff (2)
- Superplasticizer (2)
- Superplasticizers (2)
- Sustainable evaluation (2)
- Säureangriff (2)
- Thermal strain (2)
- Ultra-High Performance Concrete (UHPC) (2)
- Ultra-high performance concrete (2)
- Ultraschall (2)
- Windkanal (2)
- Wärmebehandlung (2)
- XRD (2)
- Yield stress (2)
- Zementgebundene Baustoffe (2)
- Zusatzstoffe (2)
- alkali-silica-reaction (2)
- 60 °C-Betonversuch (1)
- 60 °C-CPT (1)
- 60° C-Betonversuch (1)
- ASR damage (1)
- ASR expansion monitoring (1)
- ASR modelling (1)
- Accelerated testing (1)
- Acoustic emissions analysis (1)
- Adhesive Pull-Strength (1)
- Aggregate (1)
- Alite (1)
- Alkali-Silica Reaction (1)
- Alkali-silica-reaction (1)
- Alkali–silica reaction (1)
- Allgemeines (1)
- Altpapierrecycling (1)
- Anti-Graffiti (1)
- Anti-graffiti agent (1)
- Anwendungsbeispiele (1)
- Assessment (1)
- Assessment concept (1)
- Auslaugung (1)
- Autoclaved aerated concrete (1)
- Autogenous deformation (1)
- Automated testing (1)
- Automatische Dehnungsmessung (1)
- BOFS (1)
- Baustellenanwendung (1)
- Baustoff (1)
- Bauwerksdiagnose (1)
- Bauwerkssicherheit (1)
- Behandlungsparameter (1)
- Beton mit geringer Festigkeit (1)
- Betonfahrbahndecke (1)
- Betonfahrbahndecken (1)
- Betonfahrdecke (1)
- Betonfertigteil (1)
- Betonstahl (1)
- Betontechnik (1)
- Betonzusatzstoff (1)
- Biofilm (1)
- Biomasseasche (1)
- Biomasseverbrennung (1)
- Bioreceptivity (1)
- Blended cement (1)
- Brand (1)
- Brandschutz (1)
- Brandverhalten (1)
- Brick (1)
- Brown coal fly ash (1)
- Building and Construction (1)
- CFD (1)
- Calorimetry (1)
- Carbonation (1)
- Cement hydration (1)
- Chemischer Angriff (1)
- Chloride attack (1)
- Chloride ingress (1)
- Cleaning efficacy (1)
- Climate simulation concrete prism test (1)
- Coarsely dispersed systems (1)
- Compatibility (1)
- Composition (1)
- Compressive Cyclic loading (1)
- Compressive strenght (1)
- Computertomografie (1)
- Computertomographie (1)
- Concentration (1)
- Concrete (E) (1)
- Concrete Prism Test at 60 °C (1)
- Concrete motorway pavements (1)
- Concrete pavement (1)
- Concrete pavements (1)
- Concrete petrography (1)
- Concrete's porosity (1)
- Continuous monitoring (1)
- Cultural Heritage (1)
- Cyclic traffic loading and mechanical pre-damage (1)
- Datenmanagement (1)
- Degradation (C) (1)
- Dehnungsmessung (1)
- Denkmalpflege (1)
- Developing building materials (1)
- Diutan gum (1)
- EDX (1)
- Early cement hydration (1)
- Edelstahlschlacke (1)
- Eigenschaften (1)
- Einsatzpotenzial (1)
- Elevated temperatures (1)
- Energy and material resources (1)
- Environmental conditions (1)
- Ermüdungsverhalten (1)
- Erstarren (1)
- Ettringite (1)
- Expansion modelling (1)
- External alkalis (1)
- FAIR-Prinzip (1)
- Fahrbahn (1)
- Fahrbahndeckenbetone (1)
- Fassaden (1)
- Fast measurement (1)
- Fatigue loading (1)
- Festigkeitssteigerung (1)
- Filterrückstand (1)
- Fire (1)
- Fire Spalling (1)
- Fire resistance (1)
- Fire safety design (1)
- Flexural testing (1)
- Flow of concrete (1)
- Flow of mortar (1)
- Fluid transport (1)
- Flüssigkeitstransport (1)
- Fracture energy (1)
- Freezethaw resistance (1)
- Fresh concrete (A) (1)
- Frischbeton (1)
- Frischbetoneigenschaften (1)
- Frost-Tausalz-Beanspruchung (1)
- Frühe Rissbildung (1)
- Frühe Zementhydratation (1)
- Functionalization (1)
- General Materials Science (1)
- Gesteinskörnung (1)
- Graffiti (1)
- Green facades (1)
- HPC (1)
- HRWRA (1)
- HSC (1)
- Haftverbund (1)
- Haltezeit (1)
- Herstellungsprozesse (1)
- High resolution (1)
- High strength concrete (1)
- High-strength concrete (1)
- Hochfester Beton (1)
- Hochleistungsbetone (1)
- Holistic concept (1)
- Hydratationswärme (1)
- Hydration products (1)
- Hydraulisch (1)
- Hydrogarnet (1)
- Hydrogranat (1)
- Hydrophobic surfaces (1)
- Hydrophobic treatment (1)
- Hydrothermale Behandlung (1)
- Hydroxyellestadit (1)
- Impregnation (1)
- In-situ (1)
- In-situ XRD (1)
- Industrieabwasseraufbereitung (1)
- Industrielle Reststoffe (1)
- Influence of temperature (1)
- Innovative Prüftechnik (1)
- Instandsetzung (1)
- Instandsetzungssysteme (1)
- Internal sulfate resistance (1)
- Ionentransport (1)
- Kesselsand (1)
- Kristalline CSH-Phase (1)
- LD-Schlacke (1)
- LIBS (1)
- Laser-induced breakdown spectroscopy (1)
- Laser-induced breakldown spectroscopy (1)
- Leaching of alkalis (1)
- Leistungsfähigkeit (1)
- Limestone (1)
- Listed buildings and monuments (1)
- Low strength concrete (1)
- MRFA (1)
- Materialdaten (1)
- Materials characterisation (1)
- Mechanische Vorschädigung (1)
- Messtechnik (1)
- Metadaten (1)
- Metallurgie (1)
- Micro X-ray fluorescence analysis (1)
- Micro chemical analysis (1)
- Micro cracks (1)
- Micro structure (1)
- Micro texture (1)
- Micro-Crack (1)
- Microcracks (1)
- Microfiller (1)
- Microscopy (1)
- Mikrofiller (1)
- Mikromechanik (1)
- Mikrorissbildung (1)
- Mikrorisse (1)
- Mineralogie (1)
- Mineralogische Zusammensetzung (1)
- Mischungsentwurf (1)
- Mitigation strategies (1)
- Modeling (E) (1)
- Modelling (1)
- Modular system (1)
- Modular systems (1)
- Moisture clog (1)
- Moisture transport (1)
- Monitoring (1)
- Monitoring of damage (1)
- Mortar (1)
- Mörtel (1)
- NDT (1)
- NMR (1)
- Nachbehandlung (1)
- Nasschemie (1)
- Natural pozzolans (1)
- Natural stone (1)
- Naturstein (1)
- Natürliche Pozzolane (1)
- Nebelkammerlagerung bei 40° C (1)
- Non destructive testing (1)
- Non-destructive testing (1)
- On-Site Application III (1)
- Ontologie (1)
- Ontologien (1)
- Optical microscopy (1)
- Oscillation rheometry (1)
- PP-Fasern (1)
- Papierasche (1)
- Pavement (1)
- Pavement concrete (1)
- Performance (1)
- Performance test (1)
- Performance tests (1)
- Permeability (C) (1)
- Phase composition (1)
- Phase development (1)
- Phase stability (1)
- Photogrammetric analysis (1)
- Plastisches Schwinden (1)
- Polycarboxylate ether vicat (1)
- Polycarboxylate superplasticizer (1)
- Polymer-Zement Beton (PCC) (1)
- Polymer-Zement Spritzbeton (SPCC) (1)
- Polypropylene Fibres (1)
- Polypropylene fibers (1)
- Pore structure analysis (1)
- Portland Cement (1)
- Portland cement Initial hydration (1)
- Praxis (1)
- Preparation of thin sections (1)
- Production technology (1)
- Prüfmethoden (1)
- Puzzolane (1)
- Quasi non-destructive assessment (1)
- Raman microscopy (1)
- Rezyklierte Gesteinskörnung (1)
- Rheology (A) (1)
- Rissbildung (1)
- Risse (1)
- Road pavement (1)
- Röntgen 3D-Computertomographie (1)
- Röntgen-Computertomografie (1)
- Sample holder (1)
- Schadensanalyse (1)
- Schallemissionsprüfung (1)
- Schrumpfrisse (1)
- Schädigende AKR (1)
- Schädigungsprozesse (1)
- Secondary aggregates in concrete (1)
- Secondary cemetitious materials (1)
- Sekundärstoff (1)
- Self-Compacting Concrete (1)
- Self-consolidating concrete (1)
- Silanes (1)
- Silikastaub (1)
- Simulation (1)
- Slump flow (1)
- Spannstahl (1)
- Spatial analyses (1)
- Sphingan (1)
- Stabilizer (1)
- Stahlfasern (1)
- Starch (1)
- Steelmaking slag (1)
- Stofftransport (1)
- Stone (1)
- Stone reprofiling (1)
- Stone restoration (1)
- Strain hardening (1)
- Straßenbeton (1)
- Stress-strain-relation (1)
- Structural fire protection (1)
- Sulfate attack (C) (1)
- Sulphate attack (1)
- Sulphate-chloride attack (1)
- Superplaticizer (1)
- Surface interactions (1)
- Surface protection system (1)
- Sustainability aspects (1)
- Sustainable building (1)
- Synchrotron (1)
- Tausalz (1)
- Temperatur (1)
- Temperatureffekte (1)
- Tensile strength (1)
- Test methods (1)
- Thermal analysis (1)
- Thermo mechanical behaviour (1)
- Thermodynamik (1)
- Tobermorit (1)
- Traffic (1)
- Transient strain (1)
- Transport mechanism (1)
- Transport process (1)
- Transportprozess (1)
- Transportprozesse (1)
- Tricalcium-silicate (1)
- Tricalciumsilikat (1)
- Ultra high performance concrete (1)
- Ultra-High Performance Concrete (1)
- Ultra-High-Performance Concrete (1)
- Ultra-Hochleistungsbeton (1)
- Ultrahigh-performance concrete (1)
- Ultrahigh-performance concrete (UHPC) (1)
- Ultrahochleistungsbeton (1)
- Ultraschallgeschwindigkeit (1)
- Ultrasonic and ray (1)
- Ultrasonic testing (1)
- Ultrasonic velocity (1)
- Verformung (1)
- Verkehr (1)
- Verwertungspotential (1)
- Vicat (1)
- Viscoelastic properties (1)
- Viscosity (1)
- Viscosity modifying agents (1)
- Vorlagerungszeit (1)
- Vorschädigung (1)
- Wasserbau (1)
- Water content (1)
- Water uptake (1)
- Water/cement ratio (1)
- Weathering (1)
- Wettability (1)
- Wissengraph (1)
- X-Ray diffraction (1)
- X-ray CT (1)
- X-ray computed tomography (1)
- X-ray diffraction (1)
- X-ray diffraction (B) (1)
- X-ray diffractometry (1)
- Zerstörungsarme und zerstörungsfreie Prüfverfahren (1)
- Zerstörungsfreie Prüfung (1)
- ZfP (1)
- Zonierung (1)
- Zumahlstoff (1)
- Zusatzmittel (1)
- Zyklische Belastung (1)
- Zyklischen Belastung (1)
- autoclaving (1)
- building materials (1)
- concrete (1)
- concrete pavements (1)
- damage monitoring (1)
- durability (1)
- end-of-life phase (1)
- fatigue (1)
- gas permeability (1)
- heat treatment (1)
- masonry (1)
- mu-3D-CT (1)
- sustainability (1)
- zyklische Belastung (1)
- Äußere Alkalizufuhr (1)
- Ökobilanz (1)
Organisationseinheit der BAM
- 7 Bauwerkssicherheit (38)
- 7.1 Baustoffe (38)
- 4 Material und Umwelt (5)
- 7.4 Baustofftechnologie (5)
- 4.4 Thermochemische Reststoffbehandlung und Wertstoffrückgewinnung (4)
- 7.7 Modellierung und Simulation (2)
- 4.0 Abteilungsleitung und andere (1)
- 7.0 Abteilungsleitung und andere (1)
- 7.2 Ingenieurbau (1)
Paper des Monats
- ja (1)
Eingeladener Vortrag
- nein (22)
Fatigue induced degradation in pavement concrete and its effect on the alkali-silica reaction
(2018)
In recent years the German motorway network has seen an increase in the occurrence of damage to concrete road surfaces that can be attributed to the alkali-silica reaction (ASR). In view of the often drastically reduced service life of road surfaces due to ASR, research activity in this field has notably increased. Alongside preventative measures in concrete technology i.e. the usage of low-alkali cements, the main research focus up to now has been on the development of performance-oriented testing procedures for ASR prevention. The effects of mechanicallyinduced damage resulting from cyclic traffic and climatic loading have previously not been taken into consideration.
The assessment of the myriad degradation and transport processes necessary for an understanding of these effects requires close interaction between experiments and corresponding multi-scale models. This contribution is focused on the experiments utilizing innovative testing techniques. The research is founded on a series of fatigue tests performed on large-scale beams with simultaneous tracking of the degradation process using non-destructive evaluation methods. Subsequently, smaller test specimens were extracted from the predamaged beams for further experiments. These experiments included investigation of the influence of fatigue-induced cracks on moisture and alkali transport. Subsequent storage of the small-scale test specimens, with and without cyclic pre-damage, in an ASR-conducive environment then provided initial findings on the influence of fatigue-induced degradation on the ASR.
The results show that the degradation process can be well observed with the test Setup developed for the fatigue experiments. Further, a small but noticeable increase of mass Transport due to fatigue-induced degradation was measured, which correspondingly indicated an increased ASR damage potential.
The aim of this study was to develop a lightweight composite facade element for new buildings and for the refurbishment of existing facades. These composite elements have been developed combining an insulation layer of autoclaved aerated concrete (AAC) with an external ultrahighperformance concrete (UHPC) supporting layer. This solution allows avoiding the use of connectors and facilitates the production procedure. The structural behavior of the facade elements is mainly influenced by the presence of the upturning edges that are able to increase the stiffness of the element and reduce the thickness of the external layer. The insulation material has no influence on the structural behavior of the UHPC boxes. Flexural tests were carried out to investigate a potential detachment of the external layer from the upturning edge. The photogrammetric Analysis used during the flexural tests essentially confirmed that the bond between the two UHPC layers cast in two steps is reliable. The quality of the bond between the external layer and the upturning edge is a key parameter to define the bearing capacity of the element.
Materials that support natural biodiversity on their surfaces can compensate for human activities that have a negative impact on nature and thus contribute to a carbon-neutral and nature-positive world. Specifically designing bioreceptive materials which favor the growth of biofilms on their surface is an approach complementing conventional, macroscopic green façades. But what exactly characterizes a bioreceptive substrate and how do biofilm and substrate interact? How and why does a spontaneous colonization and the formation of biofilms take place? What are biofilms and how can they be established in a laboratory setting? How can this existing knowledge be transferred to the artificial stone concrete so that this material can be tuned to increase (or decrease) its bioreceptivity?
This review paper aims at summarizing the existing state of knowledge on bioreceptive concrete and pointing out inconsistencies and contradictions which can only be removed by more interdisciplinary research in the field.
Beton ist weltweit einer der wichtigsten Konstruktionswerkstoffe und zeichnet sich durch eine enorme Anpassungsfähigkeit an sich verändernde Anforderungen aus. Damit verbunden ist eine hohe und kontinuierlich zunehmende Komplexität hinsichtlich der Ausgangsstoffe, Rezepturen und des Herstellungsprozesses. Folglich setzt eine Ausschöpfung des technischen und umweltbezogenen Potenzials der Betonbauweise höchste Expertise bei den Einzelakteuren der Bauindustrie voraus.
Die sprunghaft zunehmende Wichtigkeit von FAIR- und Open-Data für die Qualitätssicherung, aber auch für die Nachnutzbarkeit von Daten und den Erkenntnisfortschritt führt zu enormem Flandlungsbedarf in Forschung und Entwicklung. Damit verbunden laufen derzeit vielfältige, ambitionierte Aktionen, z. B. bezüglich der Erstellung von Ontologien und Wissensgraphen. Das Knowhow entwickelt sich rasant, die Ansätze zur Implementation entstehen in verschiedenen Fachwelten bzw. mit
unterschiedlichen Zielsetzungen parallel, so dass recht heterogene Herangehensweisen resultieren.
Diese Veröffentlichung fokussiert auf Arbeiten, die derzeit als möglichst ganzheitlicher Ansatz für Materialdaten im Rahmen der Digitalisierungsinitiative „Plattform MaterialDigital" vorangetrieben werden. Die Autoren bearbeiten baustoffbezogene Aspekte im Verbundprojekt „LeBeDigital - Lebenszyklus von Beton". Zielsetzung ist die digitale Beschreibung des Materialverhaltens von Beton über den kompletten Herstellungsprozess eines Fertigteils mit einer Integration von Daten und Modellen innerhalb eines Workflows zur probabilistischen Material- und Prozessoptimierung.
Es wird über die Vorgehensweise und die dabei gewonnenen Erfahrungen berichtet, nicht ohne den Blick auf die oft unterschätzte Komplexität der Thematik zu lenken.
The adaption of the set-up for gas permeability measurements for ultra-high performance concrete
(2022)
In the framework of this project, a steam pressure vessel was to be developed from ultra-high perfor-mance concrete (UHPC) to withstand process temperatures of 200 °C and the respective steam pressure of 15,5 bar. To guarantee the long-term water vapour tightness of the system, the permeability of two UHPC mixtures were tested after long-term cyclic autoclaving. As UPHC shows a high density and therefore low permeability, measurements after the RILEM-Recommendation (TC 116-PCD) reached their detection limit. Therefore, the measurement set-up was adapted to measure the permeability of highly dense UHPC more reliably and quickly. This adaption includes measurements in a higher pres-sure range, the change of sample size thickness and the usage of Ar as a medium compared with the RILEM Recommendation. Additionally, the system was equipped with two pressure sensors and Ar-flowmeters to guarantee a continuous record of the experimental parameters. The new system was tested and evaluated by comparing measurements with the RILEM recommended system. Preliminary results show that the adapted system is capable to provide efficient and reliable results of concrete with low permeability.
Even after autoclaving for 2 weeks in the temperature range of 120 to 200 °C, CEM I paste with a water-to-cement ratio of 0.5 still contains some low-crystalline C-S-H. The conversion of low-crystalline C-S-H to crystalline is faster with increasing temperature. The observed low-crystalline and crystalline C-S-H phases (reinhardbraunsite, jaffeite) indicate that the sampleshave not reached equilibrium yet under these experimental conditions. However, there is a good agreement between experiment and thermodynamic modelling for the other solids indicating that the used datasets are suitable for this application.
Fused cement clinker can be produced from molten basic oxygen furnace slag (BOFS) by way of a reductive thermochemical treatment. During the thermochemical treatment, oxidic iron is reduced to metallic iron and separated. The resulting low-iron slag has a chemical and mineralogical composition similar to ordinary Portland cement (OPC) clinker. In this study, the hydraulic reactivity of the fused clinker from BOFS with and without gypsum was investigated using isothermal calorimetry, differential scanning calorimetry, in situ X-ray diffraction and powder X-ray diffraction. Furthermore, a synthetic fused clinker without foreign ions and fused clinker produced by a mixture of both materials was studied. The hydraulic reaction of the fused clinker from BOFS was considerably slower than that of OPC. However, the reaction can be accelerated by adding gypsum as a sulfate carrier. Furthermore, the results showed an increased reaction rate with decreasing content of foreign ions such as Fe, P or Mn.
Die Nutzung und Weiterverarbeitung von Sekundärstoffen kann in der Baustoffherstellung einen Beitrag zum nachhaltigen Bauen leisten. Im Rahmen des Teilprojekts B wurde die Bewertung dieser Potenziale anhand von Beispielen ausgebaut und verifiziert. Die Basis dieser Bewertungsgrundlage ist die Erfüllung der grundlegenden technischen Anforderungen (ökobilanzielle Indikatoren, vergleichende ökobilanzielle Betrachtung). Im Teilprojekt E geht es um die Freisetzung umweltrelevanter Stoffe aus zementgebundenen Baustoffen. Überprüft werden sollte die Übereinstimmung zwischen Laborergebnissen, Modellierungen und realen Grundwasserkonzentrationen. Es wurden Schlitzwände errichtet, die in den Grundwasserleiter einbinden und umweltrelevante Parameter bestimmt. Grundsätzlich hat sich selbst bei Großbaustellen nur eine geringe Beeinflussung der Grundwasserqualität durch Beton ergeben.
Selbstverdichtender Beton verhält sich unter Temperatureinfluss anders als Normalbeton, da die Rheologie neben der fortschreitenden Hydratation zusätzlich durch die von der Zeit und dem Hydratationsfortschritt abhängige Adsorption von Fließmitteln beeinflusst wird. Anhand rheometrischer Betonversuche an SVB unterschiedlicher Entwurfskonzepte mit variierter anionischer Ladungsdichte im Fließmittel wird verdeutlicht, dass mehlkornreiche SVB bei niedrigen Temperaturen sehr robust sind, während bei hohen Temperaturen mehlkornärmere Entwürfe zu bevorzugen sind. Darüber hinaus wird gezeigt, wie sich unterschiedliche Fließmittelmodifikationen in bestimmten Temperaturbereichen verhalten. Anhand des Wasser-Feststoff-Verhältnisses und des Adsorptionsverhaltens von Fließmitteln werden die maßgeblichen Prozesse erläutert und Möglichkeiten für die Entwicklung robuster Mischungen für individuelle Temperaturbereiche aufgeführt.--------------------------------------------------------------------------------------------------------------------------------------------------------------
Regarding the temperature dependent performance, self-compacting concrete (SCC) distinguishes from normal concrete, since its rheology does not only depend upon the hydration itself but supplementary upon the adsorption of superplasticizers, which is affected by the time and the hydration progress. Based on rheometric concrete investigations with different SCC mixture compositions and varied anionic charge densities of the superplasticizers, it is shown that SCC, which is rich in powder components, shows robust performance at low temperatures, while compositions with lower powder contents are favourable at high temperatures. Furthermore, the performance of different superplasticizer modifications at different temperature ranges is demonstrated. The relevant processes are explained by means of the water to powder ratio as well as the adsorption behaviour of superplasticizers, and options for the development of robust mixture compositions for individual temperature ranges are itemised.
Self-compacting concrete (SCC) differs substantially from normal concrete as regards the quantity of superplasticiser dosage. The functionality of superplasticisers, based on the polycarboxylate ether (PCE) superplasticiser customary with SCC, is nowadays very well understood at construction material research level. However, knowledge concerning pertinent correlations does not always permeate practice to an equal extent. PCEs are extremely polymorphic as opposed to earlier superplasticiser groups, which still possess a considerable proportion of the superplasticiser market. The geometry of polymers can be adjusted individually to performance characteristics required for certain uses. Yet, in selecting a superplasticiser for its specified rheological properties, a very strong influence can equally be exerted simultaneously on the subsequent hydration process. The charge density of the PCE employed also plays a key role in connection with both rheology and early hydration.
Polysaccharides are incorporated into cement based Systems in order to modify the rheological properties. Typically, cellulose ethers, sphingan gums, guar gum or starch ethers are applied. Depending upon their chemistry, molecular architecture, and adsorption tendency, polysaccharides interact differently with the entire cementitious system. Some stabilising agents like diutan gum mainly affect the cementitious paste; other stabilising agents like starch tend to interact with the sand fraction and even with the coarse aggregates. Cellulose and guar gum shows more diverse performances.
Typically stabilising admixtures like polysaccharides are used, when sophisticated rheological properties are adjusted. Therefore, polysaccharides are often used in combination with superplasticisers, which are added to reduce the yield stress of concrete. This can cause interactions, particularly when the stabilising Agent shows a strong tendency to adsorb on particle surfaces. Adsorptive stabilising agents may reduce the amount of adsorbed superplasticisers, thus affecting both viscosity and yield stress, while non-adsorptive stabilising agents mainly affect the plastic viscosity independently of the superplasticiser. Due to the strong influence of superplasticisers on the yield stress, influences of the stabilising agent on the yield stress retreat into the background, so that their major effect is an increase of the plastic viscosity.
The paper provides a comprehensive overview of how different polysaccharide superplasticisers affect cementitious flowable systems and points out the challenges of the combined use of polysaccharides and superplasticisers. Based on rheometric experiments and observations of the hydration process, time dependent effects on the workability as well as of the hydration of cement are presented and discussed.
Time-resolved in situ investigation of Portland cement hydration influenced by chemical admixtures
(2016)
Numerous admixtures are used in the building practice to customize the properties of the cement paste during application. The influences of admixtures on the course of cement hydration and formation of hydrate phases have to be considered. Polycarboxylate ether (PCE) based polymeric superplasticizers (SPs) are known to retard the setting of the cement paste. The extent of the retardation differs depending on the molecular structure of the SP. Additionally, the presence of a stabilizing agent (SA) in the cement paste has a retarding side effect on the setting. The initial cement hydration processes and the detailed mechanisms of the retardation influenced by PCEs, as well as their interactions with particular SAs, are insufficiently understood. Up to now, only the results of phenomenological studies were taken into account to describe this retardation process. A detailed structure analysis monitoring the change of the phase composition during the hydration was never applied. Both SP and SA affect the adsorption of the sulphate ions on the clinker particles, causing changes in the formation of ettringite during the initial hydration, and are therefore a crucial part of the setting process itself. Here, the initial hydration of cement influenced by the interaction of SP and SA was monitored in situ by synchrotron X-ray diffraction. The high time resolution of the measurements allowed a continuous detection of the hydrates formed. The hydration was followed from the starting point of water addition and for couple of hours afterwards. The hydration of the levitated cement pellets containing starch as SA was initialized by adding aqueous solutions of different commercial SPs. Changes in the ettringite formation were detected in comparison to the reference hydration of pure cement.
Industrial byproducts and natural pozzolanas are increasingly being used as supplementary cementitious materials. In the group of natural pozzolanas volcanic ashes are the most prominent. Despite the fact that volcanic pozzolanas were used since Roman times, not much is known about their role in influencing the long term durability of concrete. The paper presents results of the volcanic pozzolana ‘Rhenish trass’, which is quarried in western Germany and its role during an alkali silica reaction (ASR). Field data and laboratory experiments indicate that trass releases alkalis into the pore solution but also changes cement paste chemistry and alkali binding behavior. There seems to be a sensitive balance between alkali release and increase of alkali binding capacity, both mechanisms crucial for the course of an ASR in concrete.