Filtern
Erscheinungsjahr
Dokumenttyp
Sprache
- Englisch (32) (entfernen)
Schlagworte
- Adhesive strength (2)
- Bonding strength (2)
- Centrifuge technology (2)
- Coatings (2)
- Ellipsometrie (2)
- Flammability (2)
- High pressure airborne ultrasound (2)
- High pressure oxygen (2)
- Imaging ellipsometry (2)
- Kohlenstoffschichten (2)
Organisationseinheit der BAM
- 6 Materialchemie (9)
- 6.1 Oberflächen- und Dünnschichtanalyse (5)
- 6.7 Materialsynthese und Design (4)
- 7 Bauwerkssicherheit (2)
- 7.1 Baustoffe (2)
- 4 Material und Umwelt (1)
- 4.1 Biologische Materialschädigung und Referenzorganismen (1)
- 6.2 Material- und Oberflächentechnologien (1)
- 6.6 Physik und chemische Analytik der Polymere (1)
- 7.4 Baustofftechnologie (1)
Alkali-silica reaction (ASR) is a chemical reaction within concrete which can lead over time to cracking and spalling. Due to the complexity of the problem, it still causes damage to concrete constructions worldwide.
The publication aims to illustrate the interdisciplinary research of the German Federal Institute for Materials Research and Testing (BAM) within the last 20 years, considering all aspects of ASR topics from the macro to the micro level. First, methods for characterization and assessment of ASR risks and reaction products used at BAM are explained and classified in the international context. Subsequently the added value of the research approach by combining different, preferably nondestructive, methods across all scales is explained using specific examples from a variety of research projects. Aspects covered range from the development of new test-setups to assess aggregate reactivity, to analysis of microstructure and reaction products using microscopical, spectroscopical and X-ray methods, to the development of a testing methodology for existing concrete pavements including in-depth analysis of the visual damage indicator and the de-icing salt input using innovative testing techniques. Finally, research regarding a novel avoidance strategy that makes use of internal hydrophobization of the concrete mix is presented.
In this contribution we present a novel thermo-acoustic approach for the generation of broad band airborne ultrasound and investigate the applicability of resonance-free thermo-acoustic emitters for very short high pressure airborne ultrasound pulses. We report on measurements of thermo-acoustic emitter consisting of a 30 nm thin metallic film on a usual soda-lime glass substrate, generating sound pressure values of more than 140 dB at 60 mm distance from the transducer and compare the results with conventional piezoelectric airborne ultrasound transducers. Our experimental investigations show that such thermo-acoustic devices can be used as broad band emitters using pulse excitation.
Biofilms cause complications and high costs in both industry and medicine. Of particular interest are bacterial infections of prosthetic materials, which usually cannot be eliminated due to the high antibiotic resistance known for bacteria forming biofilms. The search for new materials and coatings with lower colonization potential and antibacterial activity is of great importance to reduce biofilm formation. However, there is no standardized procedure to examine the colonization characteristics of bacteria in the Biofilm state in situ. Here, we describe an automated epifluorescence microscopy system for the semi-quantitative analysis of three-dimensional (3D) biofilms on various surfaces. To analyze adherent bacteria, three materials (glass, steel and titanium) were incubated with bacteria in a flow chamber system. After fluorescence staining of the bacteria, automated image capturing, quantification of the bacteria, measurement of the colonized area and determination of the 3D biofilm height were carried out by using novel software.
Furthermore, the materials were examined for their surface topography using white light scanning interferometry. Titanium compared to glass showed a significantly higher number of adherent bacteria.
We argue that this was due to the higher microroughness of titanium. The colonized area was in accordance with the number of adherent bacteria and was also significantly larger on titanium coupons compared to glass. Maximum 3D biofilm height on glass coupons was significantly lower compared to the ones on steel and titanium. This novel method enables the standardized, automated investigation of the colonization with bacteria on different materials. This approach can considerably support the characterization of new material surfaces and their innovative coatings by analyzing the amount of attached Bacteria and thickness of biofilms in situ and eliminates the need of conventional cultivation.
Critical defects, also known as device killers, in wide bandgap semiconductors significantly affect the performance of power electronic devices. We used the methods imaging ellipsometry (IE) and white light interference microscopy (WLIM) in a hybrid optical metrology study for fast and non-destructive detection, classification, and characterisation of defects in 4H–SiC homoepitaxial layers on 4H–SiC substrates. Ellipsometry measurement results are confirmed by WLIM. They can be successfully applied for wafer characterisation already during production of SiC epilayers and for subsequent industrial quality control.
3D coherence scanning interferometry (CSI) is an optical, non-contact and rapide measurement technique using a defined bandwidth of white light at normal incidence. Based on this operational principle, white light interference microscopy (WLIM) provides three-dimensional surface topometry data up to a resolution of 0.4 μm lateral and 0.1 nm vertical. Three operating modi, i.e. surface, films and advanced films, enable measurements of step heights, roughness, wear volume, cone angle, surface pattern and layer thickness of transparent coatings.
The determination of layer thickness by WLIM requires the knowledge of optical constants, i.e.the refractive index n and the extinction coefficient k. For technical surfaces, data base values - if available at all - have to be determined or validated by spectroscopic ellipsometry (SE). From this oblique incidence technique both optical constants and layer thickness can be derived based on a model for at least semi-transparent coatings. For different layer thicknesses, a
comparison is made between WLIM and SE. Measurement uncertainty is
discussed for both topometric features and layer thickness for different use cases.
Traceability to SI system is ensured by certified standards (PTB/NIST) within a DAkkS DIN EN ISO/IEC 17025:2018 accredited lab.
Titanium and its alloys are known to allow the straightforward laser-based manufacturing of ordered surface nanostructures, so-called high spatial frequency laser-induced periodic surface structures (HSFL). These structures exhibit sub-100 nm spatial periods – far below the optical diffraction limit. The resulting surface functionalities are usually enabled by both, topographic and chemical alterations of the nanostructured surfaces. For exploring these effects, multi-method characterizations were performed here for HSFL processed on Ti–6Al–4V alloy upon irradiation with near-infrared ps-laser pulses (1030 nm, ≈1 ps pulse duration, 1–400 kHz) under different laser scan processing conditions, i.e., by systematically varying the pulse repetition frequency and the number of laser irradiation passes. The sample characterization involved morphological and topographical investigations by scanning electron microscopy (SEM), atomic force microscopy (AFM), tactile stylus profilometry, as well as near-surface chemical analyses hard X-ray photoelectron spectroscopy (HAXPES) and depth-profiling time-of-flight secondary ion mass spectrometry (ToF-SIMS). This provides a quantification of the laser ablation depth, the geometrical HSFL characteristics and enables new insights into the depth extent and the nature of the non-ablative laser-induced near-surface oxidation accompanying these nanostructures. This allows to answer the questions how the processing of HSFL can be industrially scaled up, and whether the latter is limited by heat-accumulation effects.
Two different test apparatuses are used at BAM to evaluate the safety of oxygen components: First, the promoted ignition combustion test according to ASTM G 124 [1] and to EIGA IGC Doc 13/02/E [2], and second, the new metallic disk ignition test that has not been standardized yet. The standard test method ASTM G 124 allows a ranking of metallic materials for use at high pressure oxygen. However, the transfer of those test results to valves and fittings in real-life situations is rather complex. The metallic disk ignition test, developed at BAM, is more practice oriented and uses metallic disks of different thicknesses of the investigated material. A commonly used nonmetallic sealing ring is placed in front of this disk and serves as an igniter. This test array is then exposed to high pressure gaseous oxygen impacts in a standardized pneumatic impact tester according to DIN EN 1797 [3].
Public, hidden, and forensic features either encoded or directly legible are used for authentication. Fabry-Perot layer stacks as information carriers in combination with imaging ellipsometry as optical read-out system provide all-in-one anti-counterfeiting capability that may establish the new security level 'encoded forensic'. Different layer designs are described with regard to all three security levels: public features (e.g. color and tilt effect) perceptible by the human eye, hidden features (e.g. spectroscopic response in the UV or IR), and forensic features (ellipsometric quantities Ψ and Δ as a function of wavelength λ and angle of incidence AOI). Physically uncloneable functions (PUF) could be realized as a result of a multi-material and a multi-parameter deposition approach as well as by means of specific design features of the Fabry-Perot layer stack. Hence, they are not subject to any reverse engineering strategies. Examples of stratified, micro-structured, and laser-modified Fabry-Perot layer systems are considered that may be used at all perception levels (e.g. human eye, bar code reader, and imaging ellipsometry) for authentication against product counterfeiting and related areas. --------------------------------------------------------------------------------------------------------------------
Zur Authentifizierung werden offene, versteckte und forensische Merkmale entweder codiert oder direkt auslesbar verwendet. Mit Fabry-Perot Schichtsystemen als Informationsträger in Kombination mit der abbildenden Ellipsometrie als optischem Auslesesystem steht ein 'all-in-one' Fälschungsschutz-System zur Verfügung, das ein neues Sicherheitsniveau 'kodiert-forensisch' darstellt. Es werden unterschiedliche Schichtdesigns beschrieben, mit denen alle drei Sicherheitsniveaus realisiert werden können: offene Merkmale (z.B. Farbe und Kippeffekt), die mit dem menschlichen Auge wahrnehmbar sind, versteckte Merkmale (z.B. die spektrale Antwort im Sichtbaren oder im IR) sowie forensische Merkmale (ellipsometrische Größen Ψ und Δ als Funktion der Wellenlänge λ und des Einfallswinkels AOI).
Physikalisch nicht klonbare Funktionen (PUF) können im Ergebnis einer Multi-Material- und Multi-Parameter Beschichtungsstrategie sowie durch spezifische Design-Merkmale des Fabry-Perot Schichtsystems realisiert werden. Folglich sind solche Schichtsysteme dem 'reverse engineering' nicht zugänglich. Es werden Beispiele für lateral ausgedehnte, mikrostrukturierte und Laser modifizierte Schichtsysteme auf verschiedenen Ausleseniveaus (menschliches Auge, Barcode-Lesegerät, abbildendes Ellipsometer) vorgestellt, die zur Authentifizierung von Produkten und verwandte Gebiete geeignet sind.
The irradiation of ~0.9-µm-thick hydrogenated amorphous carbon (a-C:H) layers deposited on silicon substrates with single femtosecond (fs) laser pulses (35 fs pulse duration, 790 nm centre wavelength) in air is studied experimentally. Irradiation spots have been generated with different peak fluences and subsequently investigated by optical topometry, micro Raman spectroscopy and microscale mechanical indentation in order to evaluate their microscopic, topographical, structural and mechanical properties (e.g. elastic modulus). By this multi-method approach, a clear separation of different effects (delamination and graphitisation) becomes possible. The joint application of mechanical and spectroscopic techniques provides unique insights into the effects of the fs-laser radiation on the carbon layer.
Hybrid optical measurement technique for detection of defects in epitaxially grown 4H-SiC layers
(2022)
Recent developments in power electronics require the use of new wide bandgap compound semiconductor. We demonstrate the use of the ellipsometry and white light interference microscopy to detect defects in epitaxially grown SiC layers on SiC substrates. Such hybrid optical metrology methods can be used to better understand the mechanism of the development of the defects as well as their effects on the material´s optoelectronic properties.